Phototimer setup for CR imaging
dc.contributor.author | Christodoulou, Emmanuel G. | |
dc.contributor.author | Goodsitt, Mitchell M. | |
dc.contributor.author | Chan, Heang‐ping | |
dc.contributor.author | Hepburn, Thomas W. | |
dc.date.accessioned | 2017-01-06T20:48:26Z | |
dc.date.available | 2017-01-06T20:48:26Z | |
dc.date.issued | 2000-12 | |
dc.identifier.citation | Christodoulou, Emmanuel G.; Goodsitt, Mitchell M.; Chan, Heang‐ping ; Hepburn, Thomas W. (2000). "Phototimer setup for CR imaging." Medical Physics 27(12): 2652-2658. | |
dc.identifier.issn | 0094-2405 | |
dc.identifier.issn | 2473-4209 | |
dc.identifier.uri | https://hdl.handle.net/2027.42/134955 | |
dc.publisher | Wiley Periodicals, Inc. | |
dc.publisher | American Association of Physicists in Medicine | |
dc.subject.other | Medical image quality | |
dc.subject.other | computed radiography | |
dc.subject.other | automatic exposure control | |
dc.subject.other | phototimer | |
dc.subject.other | Radiography | |
dc.subject.other | Photomultipliers; phototubes and photocathodes | |
dc.subject.other | Gasâ filled counters: ionization chambers, proportional, and avalanche counters | |
dc.subject.other | diagnostic radiography | |
dc.subject.other | medical image processing | |
dc.subject.other | phototubes | |
dc.subject.other | image sensors | |
dc.subject.other | ionisation chambers | |
dc.subject.other | Medical imaging | |
dc.subject.other | Computed radiography | |
dc.subject.other | Medical Xâ ray imaging | |
dc.subject.other | Radiography | |
dc.subject.other | Medical image noise | |
dc.subject.other | Image analysis | |
dc.subject.other | Radiologists | |
dc.subject.other | Xâ ray imaging | |
dc.subject.other | Ionization chambers | |
dc.title | Phototimer setup for CR imaging | |
dc.type | Article | en_US |
dc.rights.robots | IndexNoFollow | |
dc.subject.hlbsecondlevel | Medicine (General) | |
dc.subject.hlbtoplevel | Health Sciences | |
dc.description.peerreviewed | Peer Reviewed | |
dc.contributor.affiliationum | Department of Radiology, University of Michigan Medical Center, 1500 East Medical Center Drive, Ann Arbor, Michigan 48109â 0030 | |
dc.contributor.affiliationother | 12361 Duffield Road, Gaines, Michigan 48436 | |
dc.description.bitstreamurl | http://deepblue.lib.umich.edu/bitstream/2027.42/134955/1/mp9522.pdf | |
dc.identifier.doi | 10.1118/1.1319522 | |
dc.identifier.source | Medical Physics | |
dc.identifier.citedreference | H. G. Chotas, C. E. Floyd, G. A. Johnson, and C. E. Ravin, â Quality control phantom for digital chest radiography,â Radiology RADLAX --> 202, 111 â 116 ( 1997 ). RADLAX --> 0033â 8419 | |
dc.identifier.citedreference | T. S. Curry, J. E. Dowdey, and R. C. Murry, Christensen’s Physics of Diagnostic Radiology, 4th ed. (Lea and Febiger, Philadelphia, 1990), pp. 130. | |
dc.identifier.citedreference | G. T. Barnes, â Digital xâ ray image capture with image intensifier and storage phosphor plates: Imaging principles, performance and limitations,â in Digital Imaging, edited by W. R. Hendee and J. H. Trueblood (Medical Physics Publishing, Madison, WI, 1993), pp. 25â 48. | |
dc.identifier.citedreference | H. Kato, â Photosimulable phosphor radiography design considerations,â in Specification, Acceptance Testing and Quality Control of Diagnostic Xâ ray Imaging Equipment, edited by J. A. Seibert, G. T. Barnes, and R. G. Gould (AIP, Woodbury, NY, 1994), pp. 731â 770. | |
dc.identifier.citedreference | J. A. Seibert, â Photostimulable phosphor system acceptance testing,â in Medical Physics Monograph No. 20: Specification, Acceptance Testing and Quality Control of Diagnostic Xâ ray Imaging Equipment (AIP, Washington, DC, 1994), pp. 771â 880. | |
dc.identifier.citedreference | S. S. Sagel et al., â Digital mobile radiography,â J. Thorac. Imaging 5, 36 â 48 ( 1990 ). | |
dc.identifier.citedreference | J. A. Seibert, D. K. Shelton, and E. H. Moore, â Computed radiography xâ ray exposure trends,â Acad. Radiol. 3, 313 â 318 ( 1996 ). | |
dc.identifier.citedreference | Fuji Computed Radiography, Technical Review No. 3, â Automatic Setting Functions for Image Density and Range in the FCR System,â Fuji Photo Film Co. Ltd., Tokyo, Japan, 1993. | |
dc.identifier.citedreference | T. Bogucki (private communication). | |
dc.identifier.citedreference | C. Willis (private communication). | |
dc.identifier.citedreference | C. Willis and J. Lobick, â Updating the Agfa component of the AAPM task group #10 draft report on computed radiography acceptance testing and quality control,â Med. Phys. MPHYA6 --> 25, 1587 ( 1998 ). MPHYA6 --> 0094â 2405 | |
dc.identifier.citedreference | W. Hillen, U. Schiebel, and T. Zaengel, â Imaging performance of a digital storage phosphor system,â Med. Phys. MPHYA6 --> 14, 744 â 751 ( 1987 ). MPHYA6 --> 0094â 2405 | |
dc.identifier.citedreference | H. Fujita et al., â Basic imaging properties of a computed radiographic system with photostimulable phosphors,â Med. Phys. MPHYA6 --> 16, 52 â 59 ( 1989 ). MPHYA6 --> 0094â 2405 | |
dc.identifier.citedreference | D. M. Tucker and P. S. Rezentes, â The relationship between pixel value and beam quality in photostimulable phosphor imaging,â Med. Phys. MPHYA6 --> 24, 887 â 893 ( 1997 ). MPHYA6 --> 0094â 2405 | |
dc.identifier.citedreference | M. Sonoda et al., â Computed radiography utilizing scanning laser stimulated luminescence,â Radiology RADLAX --> 148, 833 â 838 ( 1983 ). RADLAX --> 0033â 8419 | |
dc.owningcollname | Interdisciplinary and Peer-Reviewed |
Files in this item
Remediation of Harmful Language
The University of Michigan Library aims to describe library materials in a way that respects the people and communities who create, use, and are represented in our collections. Report harmful or offensive language in catalog records, finding aids, or elsewhere in our collections anonymously through our metadata feedback form. More information at Remediation of Harmful Language.
Accessibility
If you are unable to use this file in its current format, please select the Contact Us link and we can modify it to make it more accessible to you.