Phototimer setup for CR imaging

dc.contributor.authorChristodoulou, Emmanuel G.
dc.contributor.authorGoodsitt, Mitchell M.
dc.contributor.authorChan, Heang‐ping
dc.contributor.authorHepburn, Thomas W.
dc.date.accessioned2017-01-06T20:48:26Z
dc.date.available2017-01-06T20:48:26Z
dc.date.issued2000-12
dc.identifier.citationChristodoulou, Emmanuel G.; Goodsitt, Mitchell M.; Chan, Heang‐ping ; Hepburn, Thomas W. (2000). "Phototimer setup for CR imaging." Medical Physics 27(12): 2652-2658.
dc.identifier.issn0094-2405
dc.identifier.issn2473-4209
dc.identifier.urihttps://hdl.handle.net/2027.42/134955
dc.publisherWiley Periodicals, Inc.
dc.publisherAmerican Association of Physicists in Medicine
dc.subject.otherMedical image quality
dc.subject.othercomputed radiography
dc.subject.otherautomatic exposure control
dc.subject.otherphototimer
dc.subject.otherRadiography
dc.subject.otherPhotomultipliers; phototubes and photocathodes
dc.subject.otherGasâ filled counters: ionization chambers, proportional, and avalanche counters
dc.subject.otherdiagnostic radiography
dc.subject.othermedical image processing
dc.subject.otherphototubes
dc.subject.otherimage sensors
dc.subject.otherionisation chambers
dc.subject.otherMedical imaging
dc.subject.otherComputed radiography
dc.subject.otherMedical Xâ ray imaging
dc.subject.otherRadiography
dc.subject.otherMedical image noise
dc.subject.otherImage analysis
dc.subject.otherRadiologists
dc.subject.otherXâ ray imaging
dc.subject.otherIonization chambers
dc.titlePhototimer setup for CR imaging
dc.typeArticleen_US
dc.rights.robotsIndexNoFollow
dc.subject.hlbsecondlevelMedicine (General)
dc.subject.hlbtoplevelHealth Sciences
dc.description.peerreviewedPeer Reviewed
dc.contributor.affiliationumDepartment of Radiology, University of Michigan Medical Center, 1500 East Medical Center Drive, Ann Arbor, Michigan 48109â 0030
dc.contributor.affiliationother12361 Duffield Road, Gaines, Michigan 48436
dc.description.bitstreamurlhttp://deepblue.lib.umich.edu/bitstream/2027.42/134955/1/mp9522.pdf
dc.identifier.doi10.1118/1.1319522
dc.identifier.sourceMedical Physics
dc.identifier.citedreferenceH. G. Chotas, C. E. Floyd, G. A. Johnson, and C. E. Ravin, â Quality control phantom for digital chest radiography,â Radiology RADLAX --> 202, 111 â 116 ( 1997 ). RADLAX --> 0033â 8419
dc.identifier.citedreferenceT. S. Curry, J. E. Dowdey, and R. C. Murry, Christensen’s Physics of Diagnostic Radiology, 4th ed. (Lea and Febiger, Philadelphia, 1990), pp. 130.
dc.identifier.citedreferenceG. T. Barnes, â Digital xâ ray image capture with image intensifier and storage phosphor plates: Imaging principles, performance and limitations,â in Digital Imaging, edited by W. R. Hendee and J. H. Trueblood (Medical Physics Publishing, Madison, WI, 1993), pp. 25â 48.
dc.identifier.citedreferenceH. Kato, â Photosimulable phosphor radiography design considerations,â in Specification, Acceptance Testing and Quality Control of Diagnostic Xâ ray Imaging Equipment, edited by J. A. Seibert, G. T. Barnes, and R. G. Gould (AIP, Woodbury, NY, 1994), pp. 731â 770.
dc.identifier.citedreferenceJ. A. Seibert, â Photostimulable phosphor system acceptance testing,â in Medical Physics Monograph No. 20: Specification, Acceptance Testing and Quality Control of Diagnostic Xâ ray Imaging Equipment (AIP, Washington, DC, 1994), pp. 771â 880.
dc.identifier.citedreferenceS. S. Sagel et al., â Digital mobile radiography,â J. Thorac. Imaging 5, 36 â 48 ( 1990 ).
dc.identifier.citedreferenceJ. A. Seibert, D. K. Shelton, and E. H. Moore, â Computed radiography xâ ray exposure trends,â Acad. Radiol. 3, 313 â 318 ( 1996 ).
dc.identifier.citedreferenceFuji Computed Radiography, Technical Review No. 3, â Automatic Setting Functions for Image Density and Range in the FCR System,â Fuji Photo Film Co. Ltd., Tokyo, Japan, 1993.
dc.identifier.citedreferenceT. Bogucki (private communication).
dc.identifier.citedreferenceC. Willis (private communication).
dc.identifier.citedreferenceC. Willis and J. Lobick, â Updating the Agfa component of the AAPM task group #10 draft report on computed radiography acceptance testing and quality control,â Med. Phys. MPHYA6 --> 25, 1587 ( 1998 ). MPHYA6 --> 0094â 2405
dc.identifier.citedreferenceW. Hillen, U. Schiebel, and T. Zaengel, â Imaging performance of a digital storage phosphor system,â Med. Phys. MPHYA6 --> 14, 744 â 751 ( 1987 ). MPHYA6 --> 0094â 2405
dc.identifier.citedreferenceH. Fujita et al., â Basic imaging properties of a computed radiographic system with photostimulable phosphors,â Med. Phys. MPHYA6 --> 16, 52 â 59 ( 1989 ). MPHYA6 --> 0094â 2405
dc.identifier.citedreferenceD. M. Tucker and P. S. Rezentes, â The relationship between pixel value and beam quality in photostimulable phosphor imaging,â Med. Phys. MPHYA6 --> 24, 887 â 893 ( 1997 ). MPHYA6 --> 0094â 2405
dc.identifier.citedreferenceM. Sonoda et al., â Computed radiography utilizing scanning laser stimulated luminescence,â Radiology RADLAX --> 148, 833 â 838 ( 1983 ). RADLAX --> 0033â 8419
dc.owningcollnameInterdisciplinary and Peer-Reviewed


Files in this item

Show simple item record

Remediation of Harmful Language

The University of Michigan Library aims to describe library materials in a way that respects the people and communities who create, use, and are represented in our collections. Report harmful or offensive language in catalog records, finding aids, or elsewhere in our collections anonymously through our metadata feedback form. More information at Remediation of Harmful Language.

Accessibility

If you are unable to use this file in its current format, please select the Contact Us link and we can modify it to make it more accessible to you.