Show simple item record

Computerized detection of noncalcified plaques in coronary CT angiography: Evaluation of topological soft gradient prescreening method and luminal analysis

dc.contributor.authorWei, Jun
dc.contributor.authorZhou, Chuan
dc.contributor.authorChan, Heang‐ping
dc.contributor.authorChughtai, Aamer
dc.contributor.authorAgarwal, Prachi
dc.contributor.authorKuriakose, Jean
dc.contributor.authorHadjiiski, Lubomir
dc.contributor.authorPatel, Smita
dc.contributor.authorKazerooni, Ella
dc.date.accessioned2017-01-06T20:50:36Z
dc.date.available2017-01-06T20:50:36Z
dc.date.issued2014-08
dc.identifier.citationWei, Jun; Zhou, Chuan; Chan, Heang‐ping ; Chughtai, Aamer; Agarwal, Prachi; Kuriakose, Jean; Hadjiiski, Lubomir; Patel, Smita; Kazerooni, Ella (2014). "Computerized detection of noncalcified plaques in coronary CT angiography: Evaluation of topological soft gradient prescreening method and luminal analysis." Medical Physics 41(8): n/a-n/a.
dc.identifier.issn0094-2405
dc.identifier.issn2473-4209
dc.identifier.urihttps://hdl.handle.net/2027.42/135084
dc.publisherAmerican Association of Physicists in Medicine
dc.publisherWiley Periodicals, Inc.
dc.subject.otherMachine learning
dc.subject.otherIn which a programme is changed according to experience gained by the computer itself during a complete run; Learning machines
dc.subject.othercomputerâ aided detection
dc.subject.otherComputerised tomographs
dc.subject.otherMultislice
dc.subject.otherAngiography
dc.subject.otherSegmentation
dc.subject.otherAlgebraic topology
dc.subject.otherNumerical approximation and analysis
dc.subject.otherblood vessels
dc.subject.othercardiology
dc.subject.othercomputerised tomography
dc.subject.otherdata analysis
dc.subject.otherdiagnostic radiography
dc.subject.otherdiseases
dc.subject.otherfeature extraction
dc.subject.otherfeature selection
dc.subject.othergeometry
dc.subject.othergradient methods
dc.subject.otherimage classification
dc.subject.otherimage segmentation
dc.subject.otherlearning (artificial intelligence)
dc.subject.othermedical image processing
dc.subject.otherobject tracking
dc.subject.othersensitivity analysis
dc.subject.othertopology
dc.subject.othercoronary CT angiography (cCTA)
dc.subject.otherBiological material, e.g. blood, urine; Haemocytometers
dc.subject.otherMethods or arrangements for processing data by operating upon the order or content of the data handled
dc.subject.othernoncalcified plaque
dc.subject.otherDigital computing or data processing equipment or methods, specially adapted for specific applications
dc.subject.otherImage data processing or generation, in general
dc.subject.otherInference methods or devices
dc.subject.otherVascular system
dc.subject.otherComputer aided diagnosis
dc.subject.otherRadiologists
dc.subject.otherComputed tomography
dc.subject.otherHeart disease
dc.subject.otherAngiography
dc.subject.otherImage reconstruction
dc.subject.otherMedical image reconstruction
dc.titleComputerized detection of noncalcified plaques in coronary CT angiography: Evaluation of topological soft gradient prescreening method and luminal analysis
dc.typeArticleen_US
dc.rights.robotsIndexNoFollow
dc.subject.hlbsecondlevelMedicine (General)
dc.subject.hlbtoplevelHealth Sciences
dc.description.peerreviewedPeer Reviewed
dc.contributor.affiliationumDepartment of Radiology, University of Michigan, Ann Arbor, Michigan 48109
dc.description.bitstreamurlhttp://deepblue.lib.umich.edu/bitstream/2027.42/135084/1/mp5958.pdf
dc.identifier.doi10.1118/1.4885958
dc.identifier.sourceMedical Physics
dc.identifier.citedreferenceP. Perona and J. Malik, â Scaleâ space and edge detection using anisotropic diffusion,â IEEE Trans. Pattern Anal. Mach. Intell. 12, 629 â 639 ( 1990 ). 10.1109/34.56205
dc.identifier.citedreferenceS. Busch, T. R. C. Johnson, K. Nikolaou, F. von Ziegler, A. Knez, M. F. Reiser, and C. R. Becker, â Visual and automatic grading of coronary artery stenoses with 64â slice CT angiography in reference to invasive angiography,â Eur. J. Radiol. 17, 1445 â 1451 ( 2007 ). 10.1007/s00330â 006â 0512â y
dc.identifier.citedreferenceS. Achenbach et al., â Detection of calcified and noncalcified coronary atherosclerotic plaque by contrastâ enhanced, submillimeter multidetector spiral computed tomography: A segmentâ based comparison with intravascular ultrasound,â Circulation 109, 14 â 17 ( 2004 ). 10.1161/01.CIR.0000111517.69230.0F
dc.identifier.citedreferenceA. W. Leber et al., â Quantification of obstructive and nonobstructive coronary lesions by 64â slice computed tomography â A comparative study with quantitative coronary angiography and intravascular ultrasound,â J. Am. Coll. Cardiol. 46, 147 â 154 ( 2005 ). 10.1016/j.jacc.2005.03.071
dc.identifier.citedreferenceB. M. Ohnesorge, T. G. Flohr, C. R. Becker, A. Knez, and M. F. Reiser, Multiâ Slice and Dualâ Source CT in Cardiac Imaging: Principles â Indications â Outlook ( Springerâ Verlag, Berlin, Germany, 2007 ).
dc.identifier.citedreferenceE. Arnoldi, M. Gebregziabher, U. J. Schoepf, R. Goldenberg, L. Ramosâ Duran, P. L. Zwerner, K. Nikolaou, M. F. Reiser, P. Costello, and C. Thilo, â Automated computerâ aided stenosis detection at coronary CT angiography: Initial experience,â Eur. J. Radiol. 20, 1160 â 1167 ( 2010 ). 10.1007/s00330â 009â 1644â 7
dc.identifier.citedreferenceP. Schoenhagen, M. Barreto, and S. S. Halliburton, â Quantitative plaque characterization with coronary CT angiography (CTA): Current challenges and future application in atherosclerosis trials and clinical risk assessment,â Int. J. Cardiovasc. Imaging 24, 313 â 316 ( 2008 ). 10.1007/s10554â 007â 9284â y
dc.identifier.citedreferenceW. G. Austen, J. E. Edwards, R. L. Frye, G. G. Gensini, V. L. Gott, L. S. Griffith, D. C. McGoon, M. L. Murphy, and B. B. Roe, â A reporting system on patients evaluated for coronary artery disease. Report of the Ad Hoc Committee for Grading of Coronary Artery Disease, Council on Cardiovascular Surgery, American Heart Association,â Circulation 51, 5 â 40 ( 1975 ). 10.1161/01.CIR.51.4.5
dc.identifier.citedreferenceC. Zhou, H.â P. Chan, A. Chughtai, S. Patel, L. M. Hadjiiski, J. Wei, and E. A. Kazerooni, â Automated coronary artery tree extraction in coronary CT angiography using a multiscale enhancement and dynamic balloon tracking (MSCARâ DBT) method,â Comput. Med. Imaging Graphics 36, 1 â 10 ( 2012 ). 10.1016/j.compmedimag.2011.04.001
dc.identifier.citedreferenceC. Zhou, H.â P. Chan, A. Chughtai, J. Kuriakose, P. Agarwal, E. A. Kazerooni, L. M. Hadjiiski, S. Patel, and J. Wei, â Computerized analysis of coronary artery disease: Performance evaluation of segmentation and tracking of coronary arteries in CT angiograms (CTA),â Med. Phys. (submitted).
dc.identifier.citedreferenceC. Zhou, H.â P. Chan, J. W. Kuriakose, A. Chughtai, J. Wei, L. M. Hadjiiski, Y. Guo, S. Patel, and E. A. Kazerooni, â Pulmonary vessel segmentation utilizing curved planar reformation and optimal path finding (CROP) in computed tomographic pulmonary angiography (CTPA) for CAD applications,â Proc. SPIE 8315, 83150N ( 2012 ). 10.1117/12.912446
dc.identifier.citedreferenceE. W. Dijkstra, â A note on two problems in connexion with graphs,â Numer. Math. 1, 269 â 271 ( 1959 ). 10.1007/BF01386390
dc.identifier.citedreferenceJ. G. Elmore et al., â Variability in interpretive performance at screening mammography and radiologistsâ characteristics associated with accuracy,â Radiology 253, 641 â 651 ( 2009 ). 10.1148/radiol.2533082308
dc.identifier.citedreferenceL. Hadjiiski, C. Zhou, H.â P. Chan, A. Chughtai, P. Agarwal, J. Kuriakose, S. Patel, J. Wei, and E. A. Kazerooni, â Automated registration of coronary arterial trees from multiple phases in coronary CT angiography (cCTA),â Proc. SPIE 8670, 86703M ( 2013 ). 10.117/12.2008058
dc.identifier.citedreferenceO. I. Saba, E. A. Hoffman, and J. M. Reinhardt, â Maximizing quantitative accuracy of lung airway lumen and wall measures obtained from Xâ ray CT imaing,â J. Appl. Physiol. 95, 1063 â 1075 ( 2003 ). 10.1152/japplphysiol.00962.2002
dc.identifier.citedreferenceC. E. Metz, â ROC methodology in radiologic imaging,â Invest. Radiol. 21, 720 â 733 ( 1986 ). 10.1097/00004424â 198609000â 00009
dc.identifier.citedreferenceB. Sahiner, H. P. Chan, N. Petrick, R. F. Wagner, and L. M. Hadjiiski, â Feature selection and classifier performance in computerâ aided diagnosis: The effect of finite sample size,â Med. Phys. 27, 1509 â 1522 ( 2000 ). 10.1118/1.599017
dc.identifier.citedreferenceC. Dorai and A. K. Jain, â COSMOS â A representation scheme for 3D freeâ form objects,â IEEE Trans. Pattern Anal. Mach. Intell. 19, 1115 â 1130 ( 1997 ). 10.1109/34.625113
dc.identifier.citedreferenceJ. Wei, C. Zhou, H.â P. Chan, A. Chughtai, S. Patel, P. Agarwal, J. Kuriakose, L. M. Hadjiiski, and E. A. Kazerooni, â Computerized detection of nonâ calcified plaques in coronary CT angiography: Topological softâ gradient detection method for plaque prescreening,â Proc. SPIE 8670, 867016 ( 2013 ). 10.1117/12.2008047
dc.identifier.citedreferenceD. Lloydâ Jones et al., â Heart disease and stroke statisticsâ 2009 update: A report from the American heart association statistics committee and stroke statistics subcommittee,â Circulation 119, e21 â e181 ( 2009 ). 10.1161/CIRCULATIONAHA.108.191261
dc.identifier.citedreferenceF. Gongoraâ Rivera, J. Labreuche, A. Jaramillo, P. G. Steg, J.â J. Hauw, and P. Amarenco, â Autopsy prevalence of coronary atherosclerosis in patients with fatal stroke,â Stroke 38, 1203 â 1210 ( 2007 ). 10.1161/01.STR.0000260091.13729.96
dc.identifier.citedreferenceP. Schoenhagen, R. D. White, S. E. Nissen, and E. M. Tuzcu, â Coronary imaging: angiography shows the stenosis, but IVUS, CT, and MRI show the plaque,â Cleveland Clin. J. Med. 70, 713 â 719 ( 2003 ). 10.3949/ccjm.70.8.713
dc.identifier.citedreferenceM. Budoff et al., â Diagnostic performance of 64â multidetector row coronary computed tomographic angiography for evaluation of coronary artery stenosis in individuals without known coronary artery disease: Results from the prospective multicenter ACCURACY (Assessment by Coronary Computed Tomographic Angiography of Individuals Undergoing Invasive Coronary Angiography) trial,â J. Am. Coll. Cardiol. 52, 1724 â 1732 ( 2008 ). 10.1016/j.jacc.2008.07.031
dc.identifier.citedreferenceJ. J. Fine, C. B. Hopkins, N. Ruff, and F. C. Newton, â Comparison of accuracy of 64â slice cardiovascular computed tomography with coronary angiography in patients with suspected coronary artery disease,â Am. J. Cardiol. 97, 173 â 174 ( 2006 ). 10.1016/j.amjcard.2005.08.021
dc.identifier.citedreferenceD. Ropers, J. Rixe, K. Anders, A. Kuttner, U. Baum, W. Bautz, W. G. Daniel, and S. Achenbach, â Usefulness of multidetector row spiral computed tomography with 64â x 0.6â mm collimation and 330â ms rotation for the noninvasive detection of significant coronary artery stenoses,â Am. J. Cardiol. 97, 343 â 348 ( 2006 ). 10.1016/j.amjcard.2005.08.050
dc.identifier.citedreferenceK. Nikolaou, A. Knez, C. Rist, B. J. Wintersperger, A. Leber, T. Johnson, M. F. Reiser, and C. R. Becker, â Accuracy of 64â MDCT in the diagnosis of ischemic heart disease,â Am. J. Roentgenol. 187, 111 â 117 ( 2006 ). 10.2214/AJR.05.1697
dc.identifier.citedreferenceG. L. Raff, M. J. Gallagher, W. W. O’Neill, and J. A. Goldstein, â Diagnostic accuracy of noninvasive coronary angiography using 64â slice spiral computed tomography,â J. Am. Coll. Cardiol. 46, 552 â 557 ( 2005 ). 10.1016/j.jacc.2005.05.056
dc.identifier.citedreferenceS. Schroeder, A. F. Kopp, A. Baumbach, C. Meisner, A. Kuettner, C. Georg, B. Ohnesorge, C. Herdeg, C. D. Claussen, and K. R. Karsch, â Noninvasive detection and evaluation of atherosclerotic coronary plaques with multislice computed tomography,â J. Am. Coll. Cardiol. 37, 1430 â 1435 ( 2001 ). 10.1016/S0735â 1097(01)01115â 9
dc.owningcollnameInterdisciplinary and Peer-Reviewed


Files in this item

Show simple item record

Remediation of Harmful Language

The University of Michigan Library aims to describe library materials in a way that respects the people and communities who create, use, and are represented in our collections. Report harmful or offensive language in catalog records, finding aids, or elsewhere in our collections anonymously through our metadata feedback form. More information at Remediation of Harmful Language.

Accessibility

If you are unable to use this file in its current format, please select the Contact Us link and we can modify it to make it more accessible to you.