Show simple item record

Cardiac Function Evaluation with Cine MRI of the Heart

dc.contributor.authorStillman, Arthur E.
dc.contributor.authorJerosch‐herold, Michael
dc.date.accessioned2018-08-13T18:47:59Z
dc.date.available2018-08-13T18:47:59Z
dc.date.issued2003-03
dc.identifier.citationStillman, Arthur E.; Jerosch‐herold, Michael (2003). "Cardiac Function Evaluation with Cine MRI of the Heart." Current Protocols in Magnetic Resonance Imaging 8(1): A11.4.1-A11.4.19.
dc.identifier.issn2572-5637
dc.identifier.issn2572-5637
dc.identifier.urihttps://hdl.handle.net/2027.42/145199
dc.publisherSeventh Meeting of the International Society for Magnetic Resonance in Medicine
dc.publisherWiley Periodicals, Inc.
dc.titleCardiac Function Evaluation with Cine MRI of the Heart
dc.typeArticleen_US
dc.rights.robotsIndexNoFollow
dc.subject.hlbsecondlevelRadiology
dc.subject.hlbsecondlevelFamily Medicine and Primary Care
dc.subject.hlbtoplevelHealth Sciences
dc.description.peerreviewedPeer Reviewed
dc.description.bitstreamurlhttps://deepblue.lib.umich.edu/bitstream/2027.42/145199/1/cpmia1104.pdf
dc.identifier.doi10.1002/0471142719.mia1104s08
dc.identifier.sourceCurrent Protocols in Magnetic Resonance Imaging
dc.identifier.citedreferenceCzegledy, F.P. and Katz, J. 1993. A new geometric description of the right ventricle. J. Biomed. Eng. 15: 387 â 391.
dc.identifier.citedreferenceDuerk, J.L., Lewin, J.S., Wendt, M., and Petersilge, C. 1998. Remember true FISP? A high SNR, near 1â second imaging method for T 2 â like contrast in interventional MRI at 2 T. J. Magn. Reson. Imaging. 8: 203 â 208.
dc.identifier.citedreferenceDulce, M.C., Mostbeck, G.H., Friese, K.K., Caputo, G.R., and Higgins, C.B. 1993. Quantification of the left ventricular volumes and function with cine MR imaging: Comparison of geometric models with threeâ dimensional data. Radiology 188: 371 â 376.
dc.identifier.citedreferenceLorenz, C.H., Walker, E.S., Morgan, V.L., Klein, S.S., and Graham, T.P. Jr. 1999. Normal human right and left ventricular mass, systolic function, and gender differences by cine magnetic resonance imaging. J. Cardiovasc. Magn. Reson. 1: 7 â 21.
dc.identifier.citedreferenceMatheijssen, N.A., Baur, L.H., Reiber, J.H., van der Velde, E.A., van Dijkman, P.R., van der Geest, R.J., de Roos, A., and van der Wall, E.E. 1996. Assessment of left ventricular volume and mass by cine magnetic resonance imaging in patients with anterior myocardial infarction intraâ observer and interâ observer variability on contour detection. Int. J. Card. Imaging 12: 11 â 19.
dc.identifier.citedreferenceNagel, E., Lehmkuhl, H.B., Bocksch, W., Klein, C., Vogel, U., Frantz, E., Ellmer, A., Dreysse, S., and Fleck, E. 1999. Noninvasive diagnosis of ischemiaâ induced wall motion abnormalities with the use of highâ dose dobutamine stress MRI: Comparison with dobutamine stress echocardiography. Circulation 99: 763 â 770.
dc.identifier.citedreferencePennell, D.J., Underwood, S.R., and Longmore, D.B. 1993. Improved cine MR imaging of left ventricular wall motion with gadopentetate dimeglumine. J. Magn. Reson. Imaging 3: 13 â 19.
dc.identifier.citedreferencePereles, F.S., Kapoor, V., Carr, J.C., Simonetti, O.P., Krupinski, E.A., Baskaran, V., and Finn, JP. 2001. Usefulness of segmented trueFISP cardiac pulse sequence in evaluation of congenital and acquired adult cardiac abnormalities. Am. J. Roentgenol. 177: 1155 â 1160.
dc.identifier.citedreferencePlein, S., Bloomer, T.N., Ridgway, J.P., Jones, T.R., Bainbridge, G.J., and Sivananthan, M.U. 2001. Steadyâ state free precession magnetic resonance imaging of the heart: Comparison with segmented k â space gradientâ echo imaging. J. Magn. Reson Imaging 14: 230 â 236.
dc.identifier.citedreferenceSchulen, V., Schick, F., Loichat, J., Helber, U., Huppert, P.E., Laub, and G., Claussen, C.D. 1996. Evaluation of k â space segmented cine sequences for fast functional cardiac imaging. Invest. Radiol. 31: 512 â 522.
dc.identifier.citedreferenceSetser, R.M., Fischer, S.E., and Lorenz, C.H. 2000. Quantification of left ventricular function with magnetic resonance images acquired in real time. J. Magn. Reson. Imaging. 12: 430 â 438.
dc.identifier.citedreferenceShellock, F.G. 1996. Pocket Guide to MR Procedures and Metallic Objects. Lippincottâ Raven, Philadelphia.
dc.identifier.citedreferenceStillman, A.E., Wilke, N., and Jeroschâ Herold, M. 1997. Use of an intravascular T 1 contrast agent to improve MR cine myocardialâ blood pool definition in man. J. Mag. Reson. Imaging 7: 765 â 767.
dc.identifier.citedreferenceThiele, H., Nagel, E., Paetsch, I., Schnackenburg, B., Bornstedt, A., Kouwenhoven, M., Wahl, A., Schuler, G., and Fleck, E. 2001. Functional cardiac MR imaging with steadyâ state free precession (SSFP) significantly improves endocardial border delineation without contrast agents. J. Magn. Reson. Imaging 14: 362 â 367.
dc.identifier.citedreferencehttp://www.medis.nl
dc.identifier.citedreferencehttp://www.siemensmedical.com
dc.identifier.citedreferenceBarkhausen, J., Ruehm, S.G., Goyen, M., Buck, T., Laub, G., and Debatin, J.F. 2001. MR evaluation of ventricular function: True fast imaging with steadyâ state precession versus fast lowâ angle shot cine MR imaging: Feasibility study. Radiology 219: 264 â 269.
dc.identifier.citedreferenceBloomgarden, D.C., Fayad, Z.A., Ferrari, V.A., Chin, B., Sutton, M.G., and Axel, L. 1997. Global cardiac function using fast breathâ hold MRI: Validation of new acquisition and analysis techniques. Magn. Reson. Med. 37: 683 â 692.
dc.identifier.citedreferenceBundy, J., Simonetti, O., Laub, G., and Finn, J.P. 1999. Segmented trueFISP cine imaging of the heart. Seventh Meeting of the International Society for Magnetic Resonance in Medicine. Philadelphia.
dc.identifier.citedreferenceChatzimavroudis, G.P., Walker, P.G., Oshinski, J.N., Franch, R.H., Pettigrew, R.I., and Yoganathan, A.P. 1997. The importance of slice location on the accuracy of aortic regurgitation measurements with magnetic resonance phase velocity mapping. Ann. Biomed. Eng. 25: 644 â 652.
dc.identifier.citedreferenceCranney, G.B., Lotan, C.S., Dean, L., Baxley, W., Bouchard, A., and Pohost, G.M. 1990. Left ventricular volume measurement using cardiac axis nuclear magnetic resonance imaging. Validation by calibrated ventricular angiography. Circulation. 82: 154 â 163.
dc.owningcollnameInterdisciplinary and Peer-Reviewed


Files in this item

Show simple item record

Remediation of Harmful Language

The University of Michigan Library aims to describe library materials in a way that respects the people and communities who create, use, and are represented in our collections. Report harmful or offensive language in catalog records, finding aids, or elsewhere in our collections anonymously through our metadata feedback form. More information at Remediation of Harmful Language.