Show simple item record

Endoscopic management of bile leaks after liver transplantation: An analysis of two high- volume transplant centers

dc.contributor.authorSendino, Oriol
dc.contributor.authorFernández‐simon, Alejandro
dc.contributor.authorLaw, Ryan
dc.contributor.authorAbu Dayyeh, Barham
dc.contributor.authorLeise, Michael
dc.contributor.authorChavez‐rivera, Karina
dc.contributor.authorCordova, Henry
dc.contributor.authorColmenero, Jordi
dc.contributor.authorCrespo, Gonzalo
dc.contributor.authorRodriguez de Miguel, Cristina
dc.contributor.authorFondevila, Constantino
dc.contributor.authorLlach, Josep
dc.contributor.authorNavasa, Miquel
dc.contributor.authorBaron, Todd
dc.contributor.authorCárdenas, Andrés
dc.date.accessioned2021-02-04T21:52:59Z
dc.date.available2021-02-04T21:52:59Z
dc.date.issued2018-02
dc.identifier.citationSendino, Oriol; Fernández‐simon, Alejandro ; Law, Ryan; Abu Dayyeh, Barham; Leise, Michael; Chavez‐rivera, Karina ; Cordova, Henry; Colmenero, Jordi; Crespo, Gonzalo; Rodriguez de Miguel, Cristina; Fondevila, Constantino; Llach, Josep; Navasa, Miquel; Baron, Todd; Cárdenas, Andrés (2018). "Endoscopic management of bile leaks after liver transplantation: An analysis of two high- volume transplant centers." UEG Journal 6(1): 89-96.
dc.identifier.issn2050-6406
dc.identifier.issn2050-6414
dc.identifier.urihttps://hdl.handle.net/2027.42/166247
dc.publisherWiley Periodicals, Inc.
dc.publisherSAGE Publications
dc.subject.otherbiliary strictures
dc.subject.otherplastic stents
dc.subject.otherbiliary stenting
dc.subject.otherBile leak
dc.subject.otherliver transplantation
dc.subject.otherbiliary complications
dc.subject.otherendoscopic retrograde cholangiopancreatography
dc.subject.othersphincterotomy
dc.titleEndoscopic management of bile leaks after liver transplantation: An analysis of two high- volume transplant centers
dc.typeArticle
dc.rights.robotsIndexNoFollow
dc.subject.hlbsecondlevelGastroenterology
dc.subject.hlbtoplevelHealth Sciences
dc.description.peerreviewedPeer Reviewed
dc.description.bitstreamurlhttp://deepblue.lib.umich.edu/bitstream/2027.42/166247/1/ueg2bf00797.pdf
dc.description.bitstreamurlhttp://deepblue.lib.umich.edu/bitstream/2027.42/166247/2/ueg2bf00797-sup-0001.pdf
dc.identifier.doi10.1177/2050640617712869
dc.identifier.doihttps://dx.doi.org/10.7302/170
dc.identifier.sourceUEG Journal
dc.identifier.citedreferenceTraina M, Tarantino I, Barresi L, et al. Efficacy and safety of fully covered self- expandable metallic stents in biliary complications after liver transplantation: A preliminary study. Liver Transpl 2009; 15: 1493 - 1498.
dc.identifier.citedreferenceRerknimitr R, Sherman S, Fogel EL, et al. Biliary tract complications after orthotopic liver transplantation with choledochocholedochostomy anastomosis: Endoscopic findings and results of therapy. Gastrointest Endosc 2002; 55: 224 - 231.
dc.identifier.citedreferencePfau PR, Kochman ML, Lewis JD, et al. Endoscopic management of postoperative biliary complications in orthotopic liver transplantation. Gastrointest Endosc 2000; 52: 55 - 63.
dc.identifier.citedreferenceWelling TH, Heidt DG, Englesbe MJ, et al. Biliary complications following liver transplantation in the model for end- stage liver disease era: Effect of donor, recipient, and technical factors. Liver Transpl 2008; 14: 73 - 80.
dc.identifier.citedreferenceThuluvath PJ, Pfau PR, Kimmey MB, et al. Biliary complications after liver transplantation: The role of endoscopy. Endoscopy 2005; 37: 857 - 863.
dc.identifier.citedreferenceThuluvath PJ, Atassi T, Lee J. An endoscopic approach to biliary complications following orthotopic liver transplantation. Liver Int 2003; 23: 156 - 162.
dc.identifier.citedreferenceSeehofer D, Eurich D, Veltzke- Schlieker W, et al. Biliary complications after liver transplantation: Old problems and new challenges. Am J Transplant 2013; 13: 253 - 265.
dc.identifier.citedreferenceShuhart MC, Kowdley KV, McVicar JP, et al. Predictors of bile leaks after T- tube removal in orthotopic liver transplant recipients. Liver Transpl Surg 1998; 4: 62 - 70.
dc.identifier.citedreferenceBjorkman DJ, Carr- Locke DL, Lichtenstein DR, et al. Postsurgical bile leaks: Endoscopic obliteration of the transpapillary pressure gradient is enough. Am J Gastroenterol 1995; 90: 2128 - 2133.
dc.identifier.citedreferenceLiao JZ, Zhao Q, Qin H, et al. Endoscopic diagnosis and treatment of biliary leak in patients following liver transplantation: A prospective clinical study. Hepatobiliary Pancreat Dis Int 2007; 6: 29 - 33.
dc.identifier.citedreferenceOstroff JW, Roberts JP, Gordon RL, et al. The management of T tube leaks in orthotopic liver transplant recipients with endoscopically placed nasobiliary catheters. Transplantation 1990; 49: 922 - 924.
dc.identifier.citedreferenceSherman S, Jamidar P, Shaked A, et al. Biliary tract complications after orthotopic liver transplantation. Endoscopic approach to diagnosis and therapy. Transplantation 1995; 60: 467 - 470.
dc.identifier.citedreferenceLlach J, Bordas JM, Elizalde JI, et al. Sphincterotomy in the treatment of biliary leakage. Hepatogastroenterology 2002; 49: 1496 - 1498.
dc.identifier.citedreferenceWard EM, Wiesner RH, Hughes RW, et al. Persistent bile leak after liver transplantation: Biloma drainage and endoscopic retrograde cholangiopancreatographic sphincterotomy. Radiology 1991; 179: 719 - 720.
dc.identifier.citedreferenceDavids PH, Rauws EA, Tytgat GN, et al. Postoperative bile leakage: Endoscopic management. Gut 1992; 33: 1118 - 1122.
dc.identifier.citedreferenceSaraswat VA, Choudhuri G, Sharma BC, et al. Endoscopic management of postoperative bile leak. J Gastroenterol Hepatol 1996; 11: 148 - 151.
dc.identifier.citedreferenceOh DW, Lee SK, Song TJ, et al. Endoscopic management of bile leakage after liver transplantation. Gut Liver 2015; 9: 417 - 423.
dc.identifier.citedreferenceSolmi L, Cariani G, Leo P, et al. Results of endoscopic retrograde cholangiopancreatography in the treatment of biliary tract complications after orthotopic liver transplantation: Our experience. Hepatogastroenterology 2007; 54: 1004 - 1008.
dc.identifier.citedreferenceDechêne A, Jochum C, Fingas C, et al. Endoscopic management is the treatment of choice for bile leaks after liver resection. Gastrointest Endosc 2014; 80: 626 - 633.e1.
dc.identifier.citedreferenceTewani SK, Turner BG, Chuttani R, et al. Location of bile leak predicts the success of ERCP performed for postoperative bile leaks. Gastrointest Endosc 2013; 77: 601 - 608.
dc.identifier.citedreferenceMorelli J, Mulcahy HE, Willner IR, et al. Endoscopic treatment of post- liver transplantation biliary leaks with stent placement across the leak site. Gastrointest Endosc 2001; 54: 471 - 475.
dc.identifier.citedreferenceWadhawan M, Kumar A, Gupta S, et al. Post- transplant biliary complications: An analysis from a predominantly living donor liver transplant center. J Gastroenterol Hepatol 2013; 28: 1056 - 1060.
dc.identifier.citedreferenceSandha GS, Bourke MJ, Haber GB, et al. Endoscopic therapy for bile leak based on a new classification: Results in 207 patients. Gastrointest Endosc 2004; 60: 567 - 574.
dc.identifier.citedreferencePhillips MS, Bonatti H, Sauer BG, et al. Elevated stricture rate following the use of fully covered self- expandable metal biliary stents for biliary leaks following liver transplantation. Endoscopy 2011; 43: 512 - 517.
dc.identifier.citedreferenceWang AY, Ellen K, Berg CL, et al. Fully covered self- expandable metallic stents in the management of complex biliary leaks: Preliminary data- a case series. Endoscopy 2009; 41: 781 - 786.
dc.identifier.citedreferenceCotton PB, Lehman G, Vennes J, et al. Endoscopic sphincterotomy complications and their management: An attempt at consensus. Gastrointest Endosc 1991; 37: 383 - 393.
dc.identifier.citedreferenceCotton PB, Eisen GM, Aabakken L, et al. A lexicon for endoscopic adverse events: Report of an ASGE workshop. Gastrointest Endosc 2010; 71: 446 - 454.
dc.identifier.citedreferenceVerdonk RC, Buis CI, Porte RJ, et al. Anastomotic biliary strictures after liver transplantation: Causes and consequences. Liver Transpl 2006; 12: 726 - 735.
dc.identifier.citedreferenceBalderramo D, Sendino O, Burrel M, et al. Risk factors and outcomes of failed endoscopic retrograde cholangiopancreatography in liver transplant recipients with anastomotic biliary strictures: A case- control study. Liver Transpl 2012; 18: 482 - 489.
dc.identifier.citedreferenceSharma S, Gurakar A, Jabbour N. Biliary strictures following liver transplantation: Past, present and preventive strategies. Liver Transpl 2008; 14: 759 - 769.
dc.identifier.citedreferenceLópez- Andújar R, Orón EM, Carregnato AF, et al. T- tube or no T- tube in cadaveric orthotopic liver transplantation: The eternal dilemma: Results of a prospective and randomized clinical trial. Ann Surg 2013; 258: 21 - 29.
dc.identifier.citedreferenceBinmoeller KF, Katon RM, Shneidman R. Endoscopic management of postoperative biliary leaks: Review of 77 cases and report of two cases with biloma formation. Am J Gastroenterol 1991; 86: 227 - 231.
dc.identifier.citedreferenceFoutch PG, Harlan JR, Hoefer M. Endoscopic therapy for patients with a post- operative biliary leak. Gastrointest Endosc 1993; 39: 416 - 421.
dc.identifier.citedreferenceSimmons DT, Petersen BT, Gostout CJ, et al. Risk of pancreatitis following endoscopically placed large- bore plastic biliary stents with and without biliary sphincterotomy for management of postoperative bile leaks. Surg Endosc 2008; 22: 1459 - 1463.
dc.identifier.citedreferenceCanena J, Horta D, Coimbra J, et al. Outcomes of endoscopic management of primary and refractory postcholecystectomy biliary leaks in a multicentre review of 178 patients. BMC Gastroenterol 2015; 15: 105 - 105.
dc.identifier.citedreferenceMangiavillano B, Manes G, Baron TH, et al. The use of double lasso, fully covered self- expandable metal stents with new - anchoring flap- system in the treatment of benign biliary diseases. Dig Dis Sci 2014; 59: 2308 - 2313.
dc.identifier.citedreferenceIrani S, Baron TH, Law R, et al. Endoscopic treatment of nonstricture- related benign biliary diseases using covered self- expandable metal stents. Endoscopy 2015; 47: 315 - 321.
dc.identifier.citedreferenceLondoño MC, Balderramo D, Cárdenas A. Management of biliary complications after orthotopic liver transplantation: The role of endoscopy. World J Gastroenterol 2008; 14: 493 - 497.
dc.identifier.citedreferenceKarimian N, Westerkamp AC, Porte RJ. Biliary complications after orthotopic liver transplantation. Curr Opin Organ Transplant 2014; 19: 209 - 216.
dc.working.doi10.7302/170en
dc.owningcollnameInterdisciplinary and Peer-Reviewed


Files in this item

Show simple item record

Remediation of Harmful Language

The University of Michigan Library aims to describe library materials in a way that respects the people and communities who create, use, and are represented in our collections. Report harmful or offensive language in catalog records, finding aids, or elsewhere in our collections anonymously through our metadata feedback form. More information at Remediation of Harmful Language.

Accessibility

If you are unable to use this file in its current format, please select the Contact Us link and we can modify it to make it more accessible to you.