Acute Cricoarytenoid Joint Fixation Following Routine Intubation: A Case Report

dc.contributor.authorSaggu, JS
dc.contributor.authorFarlow, JL
dc.contributor.authorMorrison, RJ
dc.contributor.authorMaile, MD
dc.coverage.spatialUnited States
dc.date.accessioned2024-01-09T17:13:56Z
dc.date.available2024-01-09T17:13:56Z
dc.date.issued2023-07-20
dc.identifier.issn2575-3126
dc.identifier.issn2575-3126
dc.identifier.urihttps://www.ncbi.nlm.nih.gov/pubmed/37471344
dc.identifier.urihttps://hdl.handle.net/2027.42/191964en
dc.description.abstractProlonged intubation is a common cause of injury to the posterior larynx often resulting in cricoarytenoid joint (CAJ) fixation and posterior glottic stenosis (PGS). We present a case of respiratory failure due to acute bilateral CAJ fixation and PGS following only 2 days of intubation for routine cardiac surgery. A tracheostomy was placed due to critical airway obstruction. Clinicians should remain vigilant for laryngeal injury presenting as CAJ fixation and PGS. Prompt surgical consultation is advised as early intervention is associated with reduced morbidity.
dc.format.mediumElectronic-eCollection
dc.languageeng
dc.publisherWolters Kluwer
dc.relation.haspartARTN e01706
dc.subjectHumans
dc.subjectLarynx
dc.subjectLaryngeal Diseases
dc.subjectConstriction, Pathologic
dc.subjectAirway Obstruction
dc.subjectIntubation, Intratracheal
dc.titleAcute Cricoarytenoid Joint Fixation Following Routine Intubation: A Case Report
dc.typeArticle
dc.identifier.pmid37471344
dc.description.bitstreamurlhttp://deepblue.lib.umich.edu/bitstream/2027.42/191964/2/2023_AA Pract_Acute CAJ Fixation Following Intubation.pdf
dc.identifier.doi10.1213/XAA.0000000000001706
dc.identifier.doihttps://dx.doi.org/10.7302/21965
dc.identifier.sourceA and A Practice
dc.description.versionPublished version
dc.date.updated2024-01-09T17:13:56Z
dc.identifier.orcid0000-0002-2313-8542
dc.identifier.orcid0000-0001-8236-3371
dc.description.filedescriptionDescription of 2023_AA Pract_Acute CAJ Fixation Following Intubation.pdf : Published version
dc.identifier.volume17
dc.identifier.issue7
dc.identifier.startpageE01706
dc.identifier.name-orcidSaggu, JS
dc.identifier.name-orcidFarlow, JL
dc.identifier.name-orcidMorrison, RJ; 0000-0002-2313-8542
dc.identifier.name-orcidMaile, MD; 0000-0001-8236-3371
dc.working.doi10.7302/21965en
dc.owningcollnameAnesthesiology, Department of


Files in this item

Show simple item record

Remediation of Harmful Language

The University of Michigan Library aims to describe library materials in a way that respects the people and communities who create, use, and are represented in our collections. Report harmful or offensive language in catalog records, finding aids, or elsewhere in our collections anonymously through our metadata feedback form. More information at Remediation of Harmful Language.

Accessibility

If you are unable to use this file in its current format, please select the Contact Us link and we can modify it to make it more accessible to you.