Part-load optima in bottoming-cycles
Woodward, John B.
1987-07
Citation:Woodward, John B. (1987/07)."Part-load optima in bottoming-cycles." Energy 12(7): 523-530. <http://hdl.handle.net/2027.42/26667>
Abstract: It is assumed that optimal steam conditions for a Rankine bottoming-cycle are those that produce the greatest power output. It is then demonstrated that optimal steam conditions are a function of steam-generator pinch-temperature difference, leading to the assumption that a designer of bottoming-cycles may begin with a chosen pinch-temperature difference. Further demonstration is given that the pinch-temperature difference must change in response to primary engine load changes, so that such load changes upset the optimal bottoming-cycle conditions found at primary engine-rated power. The consequences to the bottoming-cycle in terms of lost power capability are demonstrated and are found to be of small magnitude.