Test results from a uranium hadron calorimeter using wire chamber readout
Bleichert, B.; Lurken, F.; Lubelsmeyer, K.; Martyn, H. -U.; Sander, H. G.; Wallraff, W.; Azemoon, T.; Ball, R.; Leedom, I.; Longo, Michael J.
1987-03-01
Citation:Bleichert, B., Lurken, F., Lubelsmeyer, K., Martyn, H. U., Sander, H. G., Wallraff, W., Azemoon, T., Ball, R., Leedom, I., Longo, M. (1987/03/01)."Test results from a uranium hadron calorimeter using wire chamber readout." Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment 254(3): 529-534. <http://hdl.handle.net/2027.42/26795>
Abstract: A uranium gas sampling calorimeter has been tested with electrons and pions between 1 and 50 GeV. A comparative evaluation of the response and the resolution for proportional and streamer mode operation of the gas wire chamber detectors is given for two different gas mixtures.