A high-pressure gas-ionization tube calorimeter for forward detectors

dc.contributor.authorKhazins, D. M.en_US
dc.contributor.authorDemortier, L.en_US
dc.contributor.authorGiokaris, N. D.en_US
dc.contributor.authorAnderson, D. F.en_US
dc.contributor.authorCihangir, S.en_US
dc.contributor.authorZimmerman, J.en_US
dc.contributor.authorBudagov, J. A.en_US
dc.contributor.authorIvanov, G. A.en_US
dc.contributor.authorKalinin, A. I.en_US
dc.contributor.authorKuritchin, A. A.en_US
dc.contributor.authorPoroshin, N. O.en_US
dc.contributor.authorTokar, S.en_US
dc.contributor.authorFanourakis, G. K.en_US
dc.date.accessioned2006-05-10T15:35:56Z
dc.date.available2006-05-10T15:35:56Z
dc.date.issued1993-09-01en_US
dc.identifier.citationKhazins, D. M., Demortier, L., Giokaris, N. D., Anderson, D. F., Cihangir, S., Zimmerman, J., Budagov, J. A., Ivanov, G. A., Kalinin, A. I., Kuritchin, A. A., Poroshin, N. O., Tokar, S., Fanourakis, G. (1993/09/01)."A high-pressure gas-ionization tube calorimeter for forward detectors." Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment 333(2-3): 372-380. <http://hdl.handle.net/2027.42/30606>en_US
dc.identifier.urihttp://www.sciencedirect.com/science/article/B6TJM-496H643-P/2/312dfcbc45fd28f26f04ecfde7531e8cen_US
dc.identifier.urihttps://hdl.handle.net/2027.42/30606
dc.description.abstractA calorimeter design based on high-pressure gas-ionization tubes arranged nearly parallel to the incident particle direction is described. Energy, time, and position resolutions of such a calorimeter, as well as its radiation hardness and electronic noise, are discussed. Resulting characteristics meet the needs of the forward calorimetry for SSC and LHC collider experiments, and seem promising for application in other, more central parts of these experiments.en_US
dc.format.extent23718 bytes
dc.format.extent3118 bytes
dc.format.extent583753 bytes
dc.format.mimetypetext/plain
dc.format.mimetypetext/plain
dc.format.mimetypeapplication/pdf
dc.language.isoen_USen_US
dc.publisherElsevieren_US
dc.titleA high-pressure gas-ionization tube calorimeter for forward detectorsen_US
dc.typeArticleen_US
dc.rights.robotsIndexNoFollowen_US
dc.subject.hlbsecondlevelPhysicsen_US
dc.subject.hlbsecondlevelNuclear Engineering and Radiological Sciencesen_US
dc.subject.hlbtoplevelScienceen_US
dc.subject.hlbtoplevelEngineeringen_US
dc.description.peerreviewedPeer Revieweden_US
dc.contributor.affiliationotherExperimental Physics Department, The Rockefeller University, New York, NY 10021-6399, USAen_US
dc.contributor.affiliationotherExperimental Physics Department, The Rockefeller University, New York, NY 10021-6399, USAen_US
dc.contributor.affiliationotherExperimental Physics Department, The Rockefeller University, New York, NY 10021-6399, USAen_US
dc.contributor.affiliationotherFermi National Accelerator Laboratory, Batavia, IL 60510, USAen_US
dc.contributor.affiliationotherFermi National Accelerator Laboratory, Batavia, IL 60510, USAen_US
dc.contributor.affiliationotherFermi National Accelerator Laboratory, Batavia, IL 60510, USAen_US
dc.contributor.affiliationotherJoint Institute for Nuclear Research, Dubna, P.O. Box 79, 101000, Moscow, Russian Federationen_US
dc.contributor.affiliationotherJoint Institute for Nuclear Research, Dubna, P.O. Box 79, 101000, Moscow, Russian Federationen_US
dc.contributor.affiliationotherJoint Institute for Nuclear Research, Dubna, P.O. Box 79, 101000, Moscow, Russian Federationen_US
dc.contributor.affiliationotherJoint Institute for Nuclear Research, Dubna, P.O. Box 79, 101000, Moscow, Russian Federationen_US
dc.contributor.affiliationotherJoint Institute for Nuclear Research, Dubna, P.O. Box 79, 101000, Moscow, Russian Federationen_US
dc.contributor.affiliationotherJoint Institute for Nuclear Research, Dubna, P.O. Box 79, 101000, Moscow, Russian Federationen_US
dc.contributor.affiliationotherDepartment of Physics and Astronomy, University of Rochester, Rochester, NY 14627-0171, USAen_US
dc.description.bitstreamurlhttp://deepblue.lib.umich.edu/bitstream/2027.42/30606/3/0000243.pdfen_US
dc.identifier.doihttp://dx.doi.org/10.1016/0168-9002(93)91179-Qen_US
dc.identifier.sourceNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipmenten_US
dc.owningcollnameInterdisciplinary and Peer-Reviewed


Files in this item

Show simple item record

Remediation of Harmful Language

The University of Michigan Library aims to describe library materials in a way that respects the people and communities who create, use, and are represented in our collections. Report harmful or offensive language in catalog records, finding aids, or elsewhere in our collections anonymously through our metadata feedback form. More information at Remediation of Harmful Language.