Evaluation of some properties of an opaque porcelain fired simultaneously with the body porcelain,
dc.contributor.author | O'Brien, William Joseph | en_US |
dc.contributor.author | Boenke, Kenneth M. | en_US |
dc.contributor.author | Groh, Carole L. | en_US |
dc.date.accessioned | 2006-04-10T17:50:23Z | |
dc.date.available | 2006-04-10T17:50:23Z | |
dc.date.issued | 1994-10 | en_US |
dc.identifier.citation | O'Brien, William J., Boenke, Kenneth M., Groh, Carole L. (1994/10)."Evaluation of some properties of an opaque porcelain fired simultaneously with the body porcelain,." The Journal of Prosthetic Dentistry 72(4): 414-419. <http://hdl.handle.net/2027.42/31266> | en_US |
dc.identifier.uri | http://www.sciencedirect.com/science/article/B6WKW-4FTPMKW-GF/2/64c40b768f409ba5901752e558254c89 | en_US |
dc.identifier.uri | https://hdl.handle.net/2027.42/31266 | |
dc.identifier.uri | http://www.ncbi.nlm.nih.gov/sites/entrez?cmd=retrieve&db=pubmed&list_uids=7990048&dopt=citation | en_US |
dc.description.abstract | Recently, a porcelain-fused-to-metal opaque porcelain was introduced that does not require a separate firing before application of the body porcelain. The objective of this study was to determine the properties of this new opaque porcelain and its ability to bond to metal. The properties studied included flexural strength, linear firing shrinkage, coefficient of thermal expansion, powder particle size, and ability to bond to body porcelain and dental alloys. Sintering of this opaque porcelain was complete when fired at 1760 [deg] F (960 [deg] C) with a linear firing shrinkage of 13.1% +/- 0.2%. No boundary between the opaque and body porcelains could be found with a scanning electron microscope after firing at 1760 [deg] F (960 [deg] C). The mean flexural strengths were 99 +/- 7 and 101 +/- 8 MPa respectively, for this opaque porcelain and a conventional opaque porcelain, and were not significantly different as assessed with Student's t-test (p = 0.548). The coefficient of thermal expansion for this opaque porcelain was 13.3 +/- 0.2 x 10-6/ [deg] C. Particle size analysis showed a 63% increase in the particles below 5 [mu]m for this opaque porcelain and bonding to two alloys was adequate as indicated by its cohesive failure. Simultaneous firing of this special opaque porcelain and body porcelain produced satisfactory sintering, strength, and bonding to metal. | en_US |
dc.format.extent | 3698182 bytes | |
dc.format.extent | 3118 bytes | |
dc.format.mimetype | application/pdf | |
dc.format.mimetype | text/plain | |
dc.language.iso | en_US | |
dc.publisher | Elsevier | en_US |
dc.title | Evaluation of some properties of an opaque porcelain fired simultaneously with the body porcelain, | en_US |
dc.type | Article | en_US |
dc.rights.robots | IndexNoFollow | en_US |
dc.subject.hlbsecondlevel | Dentistry | en_US |
dc.subject.hlbtoplevel | Health Sciences | en_US |
dc.description.peerreviewed | Peer Reviewed | en_US |
dc.contributor.affiliationum | School of Dentistry, The University of Michigan, Ann Arbor, Mich., USA | en_US |
dc.contributor.affiliationum | School of Dentistry, The University of Michigan, Ann Arbor, Mich., USA | en_US |
dc.contributor.affiliationum | School of Dentistry, The University of Michigan, Ann Arbor, Mich., USA | en_US |
dc.identifier.pmid | 7990048 | en_US |
dc.description.bitstreamurl | http://deepblue.lib.umich.edu/bitstream/2027.42/31266/1/0000172.pdf | en_US |
dc.identifier.doi | http://dx.doi.org/10.1016/0022-3913(94)90562-2 | en_US |
dc.identifier.source | The Journal of Prosthetic Dentistry | en_US |
dc.owningcollname | Interdisciplinary and Peer-Reviewed |
Files in this item
Remediation of Harmful Language
The University of Michigan Library aims to describe library materials in a way that respects the people and communities who create, use, and are represented in our collections. Report harmful or offensive language in catalog records, finding aids, or elsewhere in our collections anonymously through our metadata feedback form. More information at Remediation of Harmful Language.
Accessibility
If you are unable to use this file in its current format, please select the Contact Us link and we can modify it to make it more accessible to you.