Show simple item record

Capillary electrophoresis/tandem mass spectrometry for analysis of proteins from two-dimensional sodium dodecyl sulfate polyacrylamide gel electrophoresis

dc.contributor.authorJin, Xiaoyingen_US
dc.contributor.authorChen, Yajuanen_US
dc.contributor.authorLubman, David M.en_US
dc.contributor.authorMisek, David E.en_US
dc.contributor.authorHanash, Samir M.en_US
dc.date.accessioned2006-04-19T14:08:04Z
dc.date.available2006-04-19T14:08:04Z
dc.date.issued1999-12-15en_US
dc.identifier.citationJin, Xiaoying; Chen, Yajuan; Lubman, David M.; Misek, David; Hanash, Samir M. (1999)."Capillary electrophoresis/tandem mass spectrometry for analysis of proteins from two-dimensional sodium dodecyl sulfate polyacrylamide gel electrophoresis." Rapid Communications in Mass Spectrometry 13(23): 2327-2334. <http://hdl.handle.net/2027.42/35078>en_US
dc.identifier.issn0951-4198en_US
dc.identifier.issn1097-0231en_US
dc.identifier.urihttps://hdl.handle.net/2027.42/35078
dc.identifier.urihttp://www.ncbi.nlm.nih.gov/sites/entrez?cmd=retrieve&db=pubmed&list_uids=10567930&dopt=citationen_US
dc.description.abstractCapillary electrophoresis/time-of-flight mass spectrometry(CE/TOFMS) has been used for analysis of in-gel digests of protein spots excised from two-dimensional sodium dodecyl sulfate polyacrylamide gel electrophoresis (2-D SDS-PAGE). An off-line purification and preconcentration procedure with a Zip Tip is used before CE/TOFMS analysis which allows for detection of protein spots with <1 picomole of material from 2-D gels. The off-line procedure provides sufficient purification for analysis while maintaining the quality of the CE separation. Using this procedure, several proteins from Coomassie Blue and zinc negatively stained gels are identified by the peptide maps generated and database searching. CE/TOF tandem mass spectrometry is used for the confirmation of database searching results and structural analysis of peptides that do not match the expected peptide maps obtained from the database in order to identify structural modifications. Several modifications were pinpointed and identified by this method. Copyright © 1999 John Wiley & Sons, Ltd.en_US
dc.format.extent106079 bytes
dc.format.extent3118 bytes
dc.format.mimetypeapplication/pdf
dc.format.mimetypetext/plain
dc.language.isoen_US
dc.publisherJohn Wiley & Sons, Ltd.en_US
dc.subject.otherChemistryen_US
dc.subject.otherAnalytical Chemistry and Spectroscopyen_US
dc.titleCapillary electrophoresis/tandem mass spectrometry for analysis of proteins from two-dimensional sodium dodecyl sulfate polyacrylamide gel electrophoresisen_US
dc.typeArticleen_US
dc.rights.robotsIndexNoFollowen_US
dc.subject.hlbtoplevelScienceen_US
dc.description.peerreviewedPeer Revieweden_US
dc.contributor.affiliationumDepartment of Chemistry, University of Michigan, Ann Arbor, MI 48109, USAen_US
dc.contributor.affiliationumDepartment of Chemistry, University of Michigan, Ann Arbor, MI 48109, USAen_US
dc.contributor.affiliationumDepartment of Chemistry, University of Michigan, Ann Arbor, MI 48109, USA ; Department of Chemistry, University of Michigan, Ann Arbor, MI 48109, USAen_US
dc.contributor.affiliationumDepartment of Pediatrics and Common Diseases, School of Medicine, University of Michigan, Ann Arbor, MI 48109, USAen_US
dc.contributor.affiliationumDepartment of Pediatrics and Common Diseases, School of Medicine, University of Michigan, Ann Arbor, MI 48109, USAen_US
dc.identifier.pmid10567930en_US
dc.description.bitstreamurlhttp://deepblue.lib.umich.edu/bitstream/2027.42/35078/1/792_ftp.pdfen_US
dc.identifier.doihttp://dx.doi.org/10.1002/(SICI)1097-0231(19991215)13:23<2327::AID-RCM792>3.0.CO;2-2en_US
dc.identifier.sourceRapid Communications in Mass Spectrometryen_US
dc.owningcollnameInterdisciplinary and Peer-Reviewed


Files in this item

Show simple item record

Remediation of Harmful Language

The University of Michigan Library aims to describe library materials in a way that respects the people and communities who create, use, and are represented in our collections. Report harmful or offensive language in catalog records, finding aids, or elsewhere in our collections anonymously through our metadata feedback form. More information at Remediation of Harmful Language.

Accessibility

If you are unable to use this file in its current format, please select the Contact Us link and we can modify it to make it more accessible to you.