Show simple item record

Angiographic and hemodynamic predictors for successful outcome of transcatheter occlusion of patent ductus arteriosus in infants less than 8 kilograms

dc.contributor.authorForbes, Thomas J.en_US
dc.contributor.authorHarahsheh, Ashrafen_US
dc.contributor.authorRodriguez-Cruz, Edwinen_US
dc.contributor.authorMorrow, William R.en_US
dc.contributor.authorThomas, Ronalden_US
dc.contributor.authorTurner, Daniel R.en_US
dc.contributor.authorVincent, Julie A.en_US
dc.date.accessioned2006-04-19T14:19:38Z
dc.date.available2006-04-19T14:19:38Z
dc.date.issued2004-01en_US
dc.identifier.citationForbes, Thomas J.; Harahsheh, Ashraf; Rodriguez-Cruz, Edwin; Morrow, William R.; Thomas, Ronald; Turner, Daniel; Vincent, Julie A. (2004)."Angiographic and hemodynamic predictors for successful outcome of transcatheter occlusion of patent ductus arteriosus in infants less than 8 kilograms." Catheterization and Cardiovascular Interventions 61(1): 117-122. <http://hdl.handle.net/2027.42/35257>en_US
dc.identifier.issn1522-1946en_US
dc.identifier.issn1522-726Xen_US
dc.identifier.urihttps://hdl.handle.net/2027.42/35257
dc.identifier.urihttp://www.ncbi.nlm.nih.gov/sites/entrez?cmd=retrieve&db=pubmed&list_uids=14696170&dopt=citationen_US
dc.description.abstractTranscatheter occlusion of patent ductus arteriosus (PDA) using Gianturco coils (GCs) has been performed for the past decade. However, little has been written regarding anatomical and hemodynamic predictors for successful occlusion of the PDA in infants. This report is to evaluate the outcome of transcatheter occlusion of PDA in symptomatic infants less than 8 kg and to assess predictors of successful occlusion. Retrospective review of catheterization charts and cineangiograms of 42 symptomatic infants who underwent cardiac catheterization for attempted transcatheter occlusion of their PDA was conducted. The hemodynamic and angiographic data evaluated included the length/diameter (L/D) ratio, defined as the length divided by the narrowest diameter of the ductus arteriosus, and preocclusion pulmonary artery pressures. Thirty-one out of 42 patients (74%) had successful occlusion. Twenty-nine out of 42 infants had an L/D ratio > 3. Of these, 26 (90%) had successful occlusion of their PDA. Thirteen out of 42 patients had an L/D ratio ≤ 3. Of these, 8 (62%) had unsuccessful occlusion. Complications encountered were transient loss of femoral arterial pulse (n = 6), coil embolization (n = 5), hemolysis (n = 2), and mild left pulmonary artery obstruction (n = 2). No permanent loss of femoral arterial pulse was noted. These complications resulted in no mortality and minimal morbidity. The L/D ratio was the strongest predictor of successful outcome, with an L/D ratio greater than 3.0 being more amenable to transcatheter occlusion (odds ratio of 4.6). Other predictors for success included lower preocclusion systolic, diastolic, and mean pulmonary artery pressure and smaller ductal diameter. Our conclusion was that infants less than 8 kg with an L/D ratio > 3.0 can safely and successfully undergo transcatheter occlusion of their PDA using transcatheter coils. Catheter Cardiovasc Interv 2004;61:117–122. © 2004 Wiley-Liss, Inc.en_US
dc.format.extent111669 bytes
dc.format.extent3118 bytes
dc.format.mimetypeapplication/pdf
dc.format.mimetypetext/plain
dc.language.isoen_US
dc.publisherWiley Subscription Services, Inc., A Wiley Companyen_US
dc.subject.otherLife and Medical Sciencesen_US
dc.subject.otherCardiovascular Medicineen_US
dc.titleAngiographic and hemodynamic predictors for successful outcome of transcatheter occlusion of patent ductus arteriosus in infants less than 8 kilogramsen_US
dc.typeArticleen_US
dc.rights.robotsIndexNoFollowen_US
dc.subject.hlbsecondlevelMedicine (General)en_US
dc.subject.hlbtoplevelHealth Sciencesen_US
dc.description.peerreviewedPeer Revieweden_US
dc.contributor.affiliationotherDepartment of Cardiology at Children's Hospital of Michigan, Wayne State University, Detroit, Michigan ; Children's Hospital of Michigan, 3901 Beaubien Boulevard, Detroit, MI 48201en_US
dc.contributor.affiliationotherDepartment of Cardiology at Children's Hospital of Michigan, Wayne State University, Detroit, Michiganen_US
dc.contributor.affiliationotherDepartment of Cardiology at Children's Hospital of Michigan, Wayne State University, Detroit, Michiganen_US
dc.contributor.affiliationotherDepartment of Cardiology at Children's Hospital of Michigan, Wayne State University, Detroit, Michiganen_US
dc.contributor.affiliationotherDepartment of Cardiology at Children's Hospital of Michigan, Wayne State University, Detroit, Michiganen_US
dc.contributor.affiliationotherDepartment of Cardiology at Children's Hospital of Michigan, Wayne State University, Detroit, Michiganen_US
dc.contributor.affiliationotherDepartment of Cardiology at Children's Hospital of Michigan, Wayne State University, Detroit, Michiganen_US
dc.identifier.pmid14696170en_US
dc.description.bitstreamurlhttp://deepblue.lib.umich.edu/bitstream/2027.42/35257/1/10751_ftp.pdfen_US
dc.identifier.doihttp://dx.doi.org/10.1002/ccd.10751en_US
dc.identifier.sourceCatheterization and Cardiovascular Interventionsen_US
dc.owningcollnameInterdisciplinary and Peer-Reviewed


Files in this item

Show simple item record

Remediation of Harmful Language

The University of Michigan Library aims to describe library materials in a way that respects the people and communities who create, use, and are represented in our collections. Report harmful or offensive language in catalog records, finding aids, or elsewhere in our collections anonymously through our metadata feedback form. More information at Remediation of Harmful Language.

Accessibility

If you are unable to use this file in its current format, please select the Contact Us link and we can modify it to make it more accessible to you.