Fabricating Tubular Devices from Polymers of Lactic and Glycolic Acid for Tissue Engineering
dc.contributor.author | Mooney, David J. | en_US |
dc.contributor.author | Breuer, C. | en_US |
dc.contributor.author | McNamara, K. | en_US |
dc.contributor.author | Vacanti, Joseph P. | en_US |
dc.contributor.author | Langer, Robert S. | en_US |
dc.date.accessioned | 2009-07-10T19:07:39Z | |
dc.date.available | 2009-07-10T19:07:39Z | |
dc.date.issued | 1995-06-01 | en_US |
dc.identifier.citation | Mooney, D.J.; Breuer, C.; McNamara, K.; Vacanti, J.P.; Langer, R. (1995). "Fabricating Tubular Devices from Polymers of Lactic and Glycolic Acid for Tissue Engineering." Tissue Engineering 1(2): 107-118 <http://hdl.handle.net/2027.42/63293> | en_US |
dc.identifier.uri | https://hdl.handle.net/2027.42/63293 | |
dc.identifier.uri | http://www.ncbi.nlm.nih.gov/sites/entrez?cmd=retrieve&db=pubmed&list_uids=19877920&dopt=citation | en_US |
dc.description.abstract | Polymers of lactic and glycolic acid are attractive candidates to fabricate devides to transplant cells and engineer new tissues. These polymers are biocompatible, and exhibit a wide range of erosion times and mechanical properties. This manuscript describes the fabrication and characterization, in vitro and in vivo, of hollow, tubular devices from porous films of various polymers of this family. Porous films of these polymers were formed using a particulate leaching technique, and sealed around Teflon cylinders to form hollow tubular devices. The erosion rate of devices was controlled by the specific polymer utilized for fabrication, and ranged from months to years. Devices fabricated from a 50/50 copolymer of D,L-lactic acid and glycolic acid were completely eroded by 2 months, while devices fabricated from a homopolymer of L-lactic acid showed little mass loss after 1 year. Erosion times for devices fabricated from the other polymers [poly-(D,L-lactic acid) and a 85/15 copolymer] were between these two extremes. Devices were capable of resisting significant compressional forces (150 raN) in vitro, and the compression resistance was controlled by the polymer utilized to fabricate the devices. The ability of the devices to maintain their structure after implantation into the mesentery or omentum of laboratory rats was also dependent of the specific polymer utilized to fabricate the device. These results indicate that it is possible to fabricate tubular devices for tissue engineering applications that exhibit a wide range of erosion rates and mechanical properties. | en_US |
dc.format.extent | 3458002 bytes | |
dc.format.extent | 2489 bytes | |
dc.format.mimetype | application/pdf | |
dc.format.mimetype | text/plain | |
dc.publisher | Mary Ann Liebert, Inc., publishers | en_US |
dc.title | Fabricating Tubular Devices from Polymers of Lactic and Glycolic Acid for Tissue Engineering | en_US |
dc.type | Article | en_US |
dc.subject.hlbtoplevel | Health Sciences | en_US |
dc.description.peerreviewed | Peer Reviewed | en_US |
dc.identifier.pmid | 19877920 | en_US |
dc.description.bitstreamurl | http://deepblue.lib.umich.edu/bitstream/2027.42/63293/1/ten.1995.1.107.pdf | |
dc.identifier.doi | doi:10.1089/ten.1995.1.107 | en_US |
dc.identifier.source | Tissue Engineering | en_US |
dc.identifier.source | Tissue Engineering | en_US |
dc.owningcollname | Interdisciplinary and Peer-Reviewed |
Files in this item
Remediation of Harmful Language
The University of Michigan Library aims to describe library materials in a way that respects the people and communities who create, use, and are represented in our collections. Report harmful or offensive language in catalog records, finding aids, or elsewhere in our collections anonymously through our metadata feedback form. More information at Remediation of Harmful Language.