JavaScript is disabled for your browser. Some features of this site may not work without it.
X-ray Diffraction Analysis of γ2 (Sn-Hg) Phase in High Copper Amalgams of Varying Mercury Content
Malhotra, Manohar; Asgar, Kamal
1981
Citation:Malhotra, Manohar; Asgar, Kamal (1981). "X-ray Diffraction Analysis of γ2 (Sn-Hg) Phase in High Copper Amalgams of Varying Mercury Content." Journal of Dental Research 2(60): 149-153. <http://hdl.handle.net/2027.42/66731>
Abstract: Microstructures of high copper commercial amalgams containing varying amounts of mercury, ranging from 20% above to 25% below recommended values, were primarily investigated by x-ray diffraction. Mechanisms relating to the absence or presence of γ2 (Sn-Hg) phase in these amalgams were discussed in relation to the presence of copper and tin elements in their original alloys. The optimum mercury concentration in some amalgams was determined in order to keep them free of the γ2 (Sn-Hg) phase.