Physical Properties of Some Zinc Oxide-Eugenol Cements

dc.contributor.authorAnderson, J.en_US
dc.contributor.authorMyers, George Elliotten_US
dc.date.accessioned2010-04-13T19:44:00Z
dc.date.available2010-04-13T19:44:00Z
dc.date.issued1966en_US
dc.identifier.citationAnderson, J.; Myers, George (1966). "Physical Properties of Some Zinc Oxide-Eugenol Cements." Journal of Dental Research 2(45): 379-387. <http://hdl.handle.net/2027.42/67707>en_US
dc.identifier.issn0022-0345en_US
dc.identifier.urihttps://hdl.handle.net/2027.42/67707
dc.format.extent3108 bytes
dc.format.extent652115 bytes
dc.format.mimetypetext/plain
dc.format.mimetypeapplication/pdf
dc.publisherSAGE Publicationsen_US
dc.titlePhysical Properties of Some Zinc Oxide-Eugenol Cementsen_US
dc.typeArticleen_US
dc.subject.hlbsecondlevelDentistryen_US
dc.subject.hlbtoplevelHealth Sciencesen_US
dc.description.peerreviewedPeer Revieweden_US
dc.contributor.affiliationumThe University of Michigan School of Dentistry, Ann Arbor, Michiganen_US
dc.contributor.affiliationumThe University of Michigan School of Dentistry, Ann Arbor, Michiganen_US
dc.description.bitstreamurlhttp://deepblue.lib.umich.edu/bitstream/2027.42/67707/2/10.1177_00220345660450022801.pdf
dc.identifier.doi10.1177/00220345660450022801en_US
dc.identifier.citedreferenceWallace, D.A., and Hansen, H.L. Council on Dental Therapeutics. Zinc Oxide-Eugenol Cements, J. Amer. dent. Ass., 26:1536-40, 1939.en_US
dc.identifier.citedreferenceMolnar, E.J., and Skinner, E.W. A Study of Zinc Oxide-Rosin Cements. 1. Some Variables Which Affect the Hardening Time, J. Amer. dent. Ass., 29: 744-51, 1942.en_US
dc.identifier.citedreferenceHarvey, W., and Petch, N.J. Acceleration of the Setting of Zinc Oxide Cements, Brit. dent. J., 80 :35-42, 1946.en_US
dc.identifier.citedreferencePaffenbarger, G.C., and Caul, H.J. Dental Cements, In Proceedings, Dental Centenary Celebration, Baltimore, Maryland, March 18-20, 1940 (George M. Anderson, editor). Baltimore, Waverly Press, 1940, p. 232-38.en_US
dc.identifier.citedreferenceSlomowitz, A. Zinc Oxide-Eugenol Setting Time Accelerated, Dent. Surv., 32:901, 1956.en_US
dc.identifier.citedreferenceMolnar, E.J. Setting Retarders for Zinc Oxide-Eugenol Pastes, Abstract #M-3., Thirty-Fifth General Meeting of the I.A.D.R., 1957.en_US
dc.identifier.citedreferenceSmith, D.C. A Quick Setting Zinc Oxide-Eugenol Mixture, Brit. dent. J., 108:232, 1960.en_US
dc.identifier.citedreferenceWeiss, M.B. Improved Zinc Oxide and Eugenol Cement, Ill. dent. J., 27:261-71, 1958.en_US
dc.identifier.citedreferencePhillips, R.W., and Love, D.R. Effects of Certain Additive Agents on the Physical Properties of Zinc Oxide-Eugenol Mixtures, J. dent. Res., 40:294-303, 1961.en_US
dc.identifier.citedreferenceMessing, J.J. Polystyrene-Fortified Zinc Oxide-Eugenol Cement, Brit. dent. J., 110:95-100, 1961.en_US
dc.identifier.citedreferenceRoland, N., Kutscher, A.H., and Ayers, H.D. Effect of Dicalcium Phosphate on the Crushing Strength of the Zinc Oxide-Eugenol Cements, N.Y. State dent. J., 25:84-86, 1959.en_US
dc.identifier.citedreferenceNorman, R.D., Swartz, M.L., and Phillips, R.W. Additional Studies on the Solubility of Certain Dental Materials, J. dent. Res., 38 :1028-37, 1959.en_US
dc.identifier.citedreferenceBrauer, G.M., and Simon, L. Synthesis of 5-Methyl-2-Propoxybenzoic Acid and Its Reaction with Zinc Oxide, J. dent. Res., 40:774-75, 1961.en_US
dc.identifier.citedreferenceBrauer, G.M., and Sanguermano, L.D. Studies to Reduce the Solubility of Zinc Oxide-o-Ethoxybenzoic Acid-Eugenol Cements, Abstract #M-5, Fortieth General Meeting of the I.A.D.R., 1962.en_US
dc.identifier.citedreferenceGivjan, S., and Brauer, G.M. Physical Properties of Cements, Based on Zinc Oxide, Hydrogenated Rosin, o-Ethoxybenzoic Acid and Eugenol, J. dent. Res., 43:281-99, 1964.en_US
dc.identifier.citedreferenceCopeland, H.I., Brauer, G.M., Sweeney, W.T., and Forziati, A.F. Setting Reaction of Zinc Oxide and Eugenol, J. Res. Nat. Bureau Stand., 55:133-38, 1955.en_US
dc.identifier.citedreferenceSmith, D.C. The Setting of Zinc Oxide-Eugenol Mixtures, Brit. dent. J., 105:313-21, 1958.en_US
dc.identifier.citedreferenceNorman, R.D., Phillips, R.W., Swartz, M.L., and Frankiewicz, T. Effect of Particle Size on the Physical Properties of Zinc Oxide-Eugenol Mixtures. J. dent. Res., 43:252-62, 1964.en_US
dc.identifier.citedreferenceSwartz, M.L., Phillips, R.W., Norman, R.D., and Oldham, D.F. Strength, Hardness and Abrasion Characteristics of Dental Cements, J. Amer. dent. Ass., 67:367-74, 1963.en_US
dc.identifier.citedreferenceOldham, D.F., Swartz, M.L., and Phillips, R.W. Retentive Properties of Dental Cements, J. prosth. Dent., 14:760-68, 1964.en_US
dc.identifier.citedreferenceSkinner, W.E., Cooper, E.N., and Ziehm, H.W. Some Physical Properties of the Zinc Oxide-Eugenol Impression Pastes, J. Amer. dent. Ass., 41:449-55, 1950.en_US
dc.identifier.citedreferenceAsgarzadeh, K., and Peyton, F.A. Physical Properties of Corrective Impression Pastes, J. prosth. Dent., 4:555-67, 1956.en_US
dc.identifier.citedreferenceVieira, D.F. Factors Affecting the Setting of Zinc Oxide-Eugenol Impression Pastes, J. prosth. Dent., 9:70-79, 1959.en_US
dc.identifier.citedreferenceClark, R.J., and Phillips, R.W. Flow Studies of Certain Dental Impression Materials, J. prosth. Dent., 7:259-66, 1957.en_US
dc.identifier.citedreferenceMyers, G.E., and Peyton, F.A. Physical Properties of the Zinc Oxide-Eugenol Impression Pastes, J. dent. Res., 40:39-48, 1961.en_US
dc.identifier.citedreferenceDubner, R., and Stanley, H.R. Reaction of the Human Dental Pulp to Temporary Filling Materials, Oral Surg., Oral Med. & Oral Path., 15:1009-17, 1962.en_US
dc.identifier.citedreferenceJames, V.E., and Schour, I. The Effects of Cavity Preparations and Zinc Oxide and Eugenol Upon the Human Pulp, Abstract #43, Thirty-Third General Meeting of the I.A.D.R., 1955.en_US
dc.identifier.citedreferenceManley, E.B. Experimental Investigation into the Early Effects of Various Filling Materials on the Human Pulp, Proc. Roy. Soc. Med. Sect. Odont., London, 34:693-706, 1941.en_US
dc.identifier.citedreferenceMjör, I.A. Effect of Calcium Hydroxide, Zinc Oxide-Eugenol and Amalgam on the Pulp, Odont. Tidskrif., 71:94-105, 1963.en_US
dc.identifier.citedreferenceBaraban, D.J. Cementation of Fixed Bridge Prosthesis with Zinc Oxide-Eugenol Cements, J. prosth. Dent., 8:988-91, 1958.en_US
dc.identifier.citedreferenceHorn, H.R. Improved Cementation, J. dent. Res., 39:760, 1960. Abstract.en_US
dc.identifier.citedreferenceAmerican Dental Association. Specifications for Dental Materials, ed. 2. Chicago, American Dental Association, 1964, p. 104-107.en_US
dc.owningcollnameInterdisciplinary and Peer-Reviewed


Files in this item

Show simple item record

Remediation of Harmful Language

The University of Michigan Library aims to describe library materials in a way that respects the people and communities who create, use, and are represented in our collections. Report harmful or offensive language in catalog records, finding aids, or elsewhere in our collections anonymously through our metadata feedback form. More information at Remediation of Harmful Language.

Accessibility

If you are unable to use this file in its current format, please select the Contact Us link and we can modify it to make it more accessible to you.