Show simple item record

Diagnosis of Atrial Fibrillation Using Electrograms from Chronic Leads: Evaluation of Computer Algorithms

dc.contributor.authorJenkins, Janice M.en_US
dc.contributor.authorNoh, Ki Hongen_US
dc.contributor.authorGuezennec, Alainen_US
dc.contributor.authorBump, Thomasen_US
dc.contributor.authorArzbaecher, Roberten_US
dc.date.accessioned2010-06-01T18:25:14Z
dc.date.available2010-06-01T18:25:14Z
dc.date.issued1988-05en_US
dc.identifier.citationJENKINS, JANICE; NOH, KI HONG; GUEZENNEC, ALAIN; BUMP, THOMAS; ARZBAECHER, ROBERT (1988). "Diagnosis of Atrial Fibrillation Using Electrograms from Chronic Leads: Evaluation of Computer Algorithms." Pacing and Clinical Electrophysiology 11(5): 622-631. <http://hdl.handle.net/2027.42/71628>en_US
dc.identifier.issn0147-8389en_US
dc.identifier.issn1540-8159en_US
dc.identifier.urihttps://hdl.handle.net/2027.42/71628
dc.identifier.urihttp://www.ncbi.nlm.nih.gov/sites/entrez?cmd=retrieve&db=pubmed&list_uids=2456541&dopt=citationen_US
dc.format.extent1507836 bytes
dc.format.extent3109 bytes
dc.format.mimetypeapplication/pdf
dc.format.mimetypetext/plain
dc.publisherBlackwell Publishing Ltden_US
dc.rights1988 Official journal of the International Cardiac Pacing and Electrophysiology Societyen_US
dc.subject.otherAtrial Fibrillationen_US
dc.subject.otherAtrial Rate Analysisen_US
dc.subject.otherAmplitude Distribution Analysisen_US
dc.subject.otherFrequency Spectral Analysisen_US
dc.titleDiagnosis of Atrial Fibrillation Using Electrograms from Chronic Leads: Evaluation of Computer Algorithmsen_US
dc.typeArticleen_US
dc.subject.hlbsecondlevelPhysiologyen_US
dc.subject.hlbtoplevelHealth Sciencesen_US
dc.description.peerreviewedPeer Revieweden_US
dc.contributor.affiliationum* The University of Michigan, Ann Arbor, MIen_US
dc.contributor.affiliationotherPritzker Institute of Medical Engineering, IIT Center, Chicago, ILen_US
dc.contributor.affiliationother** The University of Chicago, Chicago, ILen_US
dc.identifier.pmid2456541en_US
dc.description.bitstreamurlhttp://deepblue.lib.umich.edu/bitstream/2027.42/71628/1/j.1540-8159.1988.tb04558.x.pdf
dc.identifier.doi10.1111/j.1540-8159.1988.tb04558.xen_US
dc.identifier.sourcePacing and Clinical Electrophysiologyen_US
dc.identifier.citedreferenceArzbaecher R, Bump T, Munkenbeck F, et al. An algorithm for automatic infusion of procainamide in acute management of paroxysmal atrial fibrillation. Computers in Cardiology. 1984, p. 57.en_US
dc.identifier.citedreferenceJenkins J, Bump T, Click K, et al. Automated recognition of tachycardias from electrograms: Decision rules for diagnosis. Computers in Cardiology. 1983, p, 93.en_US
dc.identifier.citedreferenceJenkins J, Bump T, Munkenbeck F, et al. Tachycardia detection in implantable antitachycardia devices. PACE 1984; 7: 1273.en_US
dc.identifier.citedreferenceArzbaecher R, Bump T, Jenkins J, et al. Automated tachycardia recognition. PACE 1984; 7: 541.en_US
dc.identifier.citedreferenceEcht D. Potential hazards of implanted devices for the electrical control of tachyarrhythmia. PACE 14. 1984; 7: 580.en_US
dc.identifier.citedreferenceFurman S, Fisher JD, Pannizzo F. Necessity of signal processing in tachycardia detection. In SS Barold and J Mugica ( Eds ): The Third Decade of Cardiac Pacing. Mount Kisco, New York, Futura Publishing Co., 1982, p. 265.en_US
dc.identifier.citedreferenceDeCaprio V, Hurzeler P, Furman S. A comparison of unipolar and bipolar electrograms for cardiac pacemaker sensing. Circulation 1977; 56: 750.en_US
dc.identifier.citedreferenceKleinert M, Elmquist H, Strandberg H. Spectral properties of atrial and ventricular endocardial signals. PACE 1979; 2: 11.en_US
dc.identifier.citedreferenceParsonnet V, Myers CH, Kresh YM. Characteristics of intracardiac electrograms II. Atrial endocardial electrograms. PACE 1980; 3: 406.en_US
dc.identifier.citedreferenceMorkrid L, Ohm OJ, Engedal H. Time domain and spectral analysis of electrograms in man during regular ventricular activity and ventricular fibrillation. IEEE Trans Biomed Eng 1984; BME-31: 350.en_US
dc.identifier.citedreferenceColdreyer BN, Almquist CK, Beck RC, et al. Wave form and frequency analysis of unipolar, bipolar, and orthogonal atrial electrograms. (Abstr) PACE 1986; 6: 283.en_US
dc.identifier.citedreferenceParker B. Fourier Analysis of electrograms. PACE 1979; 2: 246.en_US
dc.identifier.citedreferenceSlocum J, Sahakian A, Swiryn S. Characteristics of atrial fibrillation. Computer Interpretation of the Electrocardiogram XI. New York, New York. Engineering Foundation, 1986. p, 102.en_US
dc.identifier.citedreferenceMirowski M, Mower MM, Reid P, et al. The automatic implantable defibrillator. PACE 1982; 5: 384.en_US
dc.identifier.citedreferenceLin D, Jenkins J, Jadvar H, DiCarlo L. Analysis of time and frequency domain patterns of endocardial electrograms to distinguish ventricular tachycardia from sinus rhythm. Computers in Cardiology 1986, p. 171.en_US
dc.identifier.citedreferenceAhmed N, Natarajan T. Discrete-Time Signals and Systems. Reston, Virginia, Reston Publishing Co., Inc., 1983.en_US
dc.identifier.citedreferenceRichards PI. Computing reliable power spectra. IEEE Spectrum 1967; 4: 83.en_US
dc.identifier.citedreferenceBingham C, Godfrey MD, Tukey JW. Modern techniques of power spectrum estimation. IEEE Trans Audio Electroacoustics 1967; AU-15: 56.en_US
dc.identifier.citedreferenceWelch PD. The use of fast Fourier transform for the estimation of power spectra: A method based on time averaging over short, modified periodograms. IEEE Trans Audio Electroacoustics 1967; AU-15: 70.en_US
dc.identifier.citedreferenceKorr CR, Mason MA. Amplitude of atrial electrical activity during sinus rhythm and during atrial fibrillation. PACE 1985; 8: 348.en_US
dc.owningcollnameInterdisciplinary and Peer-Reviewed


Files in this item

Show simple item record

Remediation of Harmful Language

The University of Michigan Library aims to describe library materials in a way that respects the people and communities who create, use, and are represented in our collections. Report harmful or offensive language in catalog records, finding aids, or elsewhere in our collections anonymously through our metadata feedback form. More information at Remediation of Harmful Language.

Accessibility

If you are unable to use this file in its current format, please select the Contact Us link and we can modify it to make it more accessible to you.