Show simple item record

Provisional Prosthetic Management of Mobile Teeth in Conjunction with a Removable Partial Denture Using Orthodontic Wire

dc.contributor.authorOh, Won-suken_US
dc.contributor.authorSaglik, Bernaen_US
dc.date.accessioned2010-06-01T18:31:34Z
dc.date.available2010-06-01T18:31:34Z
dc.date.issued2009-10en_US
dc.identifier.citationOh, Won-suk; Saglik, Berna (2009). "Provisional Prosthetic Management of Mobile Teeth in Conjunction with a Removable Partial Denture Using Orthodontic Wire." Journal of Prosthodontics 18(7): 638-640. <http://hdl.handle.net/2027.42/71732>en_US
dc.identifier.issn1059-941Xen_US
dc.identifier.issn1532-849Xen_US
dc.identifier.urihttps://hdl.handle.net/2027.42/71732
dc.identifier.urihttp://www.ncbi.nlm.nih.gov/sites/entrez?cmd=retrieve&db=pubmed&list_uids=19523023&dopt=citationen_US
dc.description.abstractPrecision attachment-retained removable partial dentures eliminate the use of visible clasps and improve the esthetic appearance of the smile; however, terminal abutment teeth may be subject to unfavorable stresses under function when misused. A provisional prosthetic management technique that incorporates an orthodontic wire to assist cross-arch support and stability of the periodontally weakened abutment teeth is described. This technique is simple, reversible, does not alter the esthetic appearance of the smile, and controls the mobility of the abutment teeth until a definitive treatment plan is established.en_US
dc.format.extent283201 bytes
dc.format.extent3109 bytes
dc.format.mimetypeapplication/pdf
dc.format.mimetypetext/plain
dc.publisherBlackwell Publishing Incen_US
dc.rights© 2009 American College of Prosthodontistsen_US
dc.subject.otherPrecision Attachment-retained Removable Partial Denturesen_US
dc.subject.otherProvisional Prosthetic Managementen_US
dc.subject.otherAbutment Tooth Mobilityen_US
dc.subject.otherSupporten_US
dc.subject.otherStabilityen_US
dc.titleProvisional Prosthetic Management of Mobile Teeth in Conjunction with a Removable Partial Denture Using Orthodontic Wireen_US
dc.typeArticleen_US
dc.subject.hlbsecondlevelDentistryen_US
dc.subject.hlbtoplevelHealth Sciencesen_US
dc.description.peerreviewedPeer Revieweden_US
dc.contributor.affiliationumClinical Associate Professor, Department of Biologic & Materials Sciences, Division of Prosthodontics, University of Michigan School of Dentistry, Ann Arbor, MIen_US
dc.contributor.affiliationumClinical Assistant Professor, Department of Biologic & Materials Sciences, Division of Prosthodontics, University of Michigan School of Dentistry, Ann Arbor, MIen_US
dc.identifier.pmid19523023en_US
dc.description.bitstreamurlhttp://deepblue.lib.umich.edu/bitstream/2027.42/71732/1/j.1532-849X.2009.00494.x.pdf
dc.identifier.doi10.1111/j.1532-849X.2009.00494.xen_US
dc.identifier.sourceJournal of Prosthodonticsen_US
dc.identifier.citedreferenceGoodkind RJ: The effects of removable partial dentures on abutment tooth mobility: a clinical study. J Prosthet Dent 1973; 30: 139 - 146en_US
dc.identifier.citedreferenceKern M, Wagner B: Periodontal findings in patients 10 years after insertion of removable partial dentures. J Oral Rehabil 2001; 28: 991 - 997en_US
dc.identifier.citedreferenceAkaltan F, Kaynak D: An evaluation of the effects of two distal extension removable partial denture designs on tooth stabilization and periodontal health. J Oral Rehabil 2005; 32: 823 - 829en_US
dc.identifier.citedreferenceClayton JA, Jaslow CA: Measurement of clasp forces on teeth. J Prosthet Dent 1971; 25: 21 - 42en_US
dc.identifier.citedreferenceFrechette AR: Partial denture planning with special reference to stress distribution. J Prosthet Dent 1951; 1: 710 - 724en_US
dc.identifier.citedreferenceKratochvil FJ: Maintaining supporting structures with a removable partial prosthesis. J Prosthet Dent 1971; 25: 167 - 174en_US
dc.identifier.citedreferenceTalbot TR: Review of the Swinglock removable partial denture. Int J Prosthodont 1991; 4: 80 - 88en_US
dc.identifier.citedreferenceAydinlik E, DayangaÇ B, Celik E: Effect of splinting on abutment tooth movement. J Prosthet Dent 1983; 49: 477 - 480en_US
dc.identifier.citedreferenceChou TM, Caputo AA, Moore DJ, Xiao B: Photoelastic analysis and comparison of force transmission characteristics of intracoronal attachments with clasp distal extension removable partial dentures. J Prosthet Dent 1989; 62: 313 - 319en_US
dc.identifier.citedreferenceChou TM, Eick JD, Moore DJ, Tira DE: Steriophotogrammetric analysis of abutment tooth movement in distal extension removable partial dentures with intracoronal attachments and clasps. J Prosthet Dent 1991; 66: 343 - 349en_US
dc.owningcollnameInterdisciplinary and Peer-Reviewed


Files in this item

Show simple item record

Remediation of Harmful Language

The University of Michigan Library aims to describe library materials in a way that respects the people and communities who create, use, and are represented in our collections. Report harmful or offensive language in catalog records, finding aids, or elsewhere in our collections anonymously through our metadata feedback form. More information at Remediation of Harmful Language.

Accessibility

If you are unable to use this file in its current format, please select the Contact Us link and we can modify it to make it more accessible to you.