Show simple item record

Hemolytic Anemia Due to Anti-A in Concentrated Antihemophilic Factor Preparations

dc.contributor.authorRosati, Louis A.en_US
dc.contributor.authorBarnes, B.en_US
dc.contributor.authorOberman, Harold A.en_US
dc.contributor.authorPenner, John A.en_US
dc.date.accessioned2010-06-01T19:35:19Z
dc.date.available2010-06-01T19:35:19Z
dc.date.issued1970-05-06en_US
dc.identifier.citationRosati, L. A.; Barnes, B.; Oberman, H. A.; Penner, J. A. (1970). "Hemolytic Anemia Due to Anti-A in Concentrated Antihemophilic Factor Preparations." Transfusion 10(3): 139-141. <http://hdl.handle.net/2027.42/72725>en_US
dc.identifier.issn0041-1132en_US
dc.identifier.issn1537-2995en_US
dc.identifier.urihttps://hdl.handle.net/2027.42/72725
dc.identifier.urihttp://www.ncbi.nlm.nih.gov/sites/entrez?cmd=retrieve&db=pubmed&list_uids=5422224&dopt=citationen_US
dc.format.extent214945 bytes
dc.format.extent3109 bytes
dc.format.mimetypeapplication/pdf
dc.format.mimetypetext/plain
dc.publisherBlackwell Publishing Ltden_US
dc.rights1970 AABBen_US
dc.titleHemolytic Anemia Due to Anti-A in Concentrated Antihemophilic Factor Preparationsen_US
dc.typeArticleen_US
dc.subject.hlbsecondlevelOncology and Hematologyen_US
dc.subject.hlbtoplevelHealth Sciencesen_US
dc.description.peerreviewedPeer Revieweden_US
dc.contributor.affiliationumDepartments of Pathology and Internal Medicine (Simpson Memorial Institute), University of Michigan, Ann Arbor, Michiganen_US
dc.identifier.pmid5422224en_US
dc.description.bitstreamurlhttp://deepblue.lib.umich.edu/bitstream/2027.42/72725/1/j.1537-2995.1970.tb00721.x.pdf
dc.identifier.doi10.1111/j.1537-2995.1970.tb00721.xen_US
dc.identifier.sourceTransfusionen_US
dc.identifier.citedreferenceDarnborough, J.: The anti-A antibody content of pooled plasma. J. Clin. Path. 16: 74, 1963.en_US
dc.identifier.citedreferenceMarder, V. J., and N. R. Shulman: Major surgery in classic hemophilia using Fraction I. Amer. J. Med. 41: 56, 1966.en_US
dc.identifier.citedreferenceMollison, P. L.: Blood Transfusion in Clinical Medicine, 4th edition. Philadelphia, F. A. Davis Co., 1967.en_US
dc.identifier.citedreferenceOberman, H. A., B. A. Barnes, and P. L. Ginther: Erythrocyte sensitization and anemia due to isoantibodies in lyophilized pooled plasma. JAMA 198: 323, 1966.en_US
dc.identifier.citedreferenceRutzky, J., F. Cohen, and W. W. Zuelzer: Anti-A agglutinins in pooled plasma as a cause of hemolytic anemia. Blood 11: 403, 1956.en_US
dc.identifier.citedreference6. Technical Methods of the American Association of Blood Banks, fourth edition. Chicago, American Association of Blood Banks, 1966.en_US
dc.identifier.citedreferenceTopley, E., J. P. Bull, W. Maycock, A. E. Mourant, and D. Parkins: The relation of the isoagglutinins in pooled plasma to the hemolytic anemia of burns. J. Clin. Path. 16: 79, 1963.en_US
dc.owningcollnameInterdisciplinary and Peer-Reviewed


Files in this item

Show simple item record

Remediation of Harmful Language

The University of Michigan Library aims to describe library materials in a way that respects the people and communities who create, use, and are represented in our collections. Report harmful or offensive language in catalog records, finding aids, or elsewhere in our collections anonymously through our metadata feedback form. More information at Remediation of Harmful Language.

Accessibility

If you are unable to use this file in its current format, please select the Contact Us link and we can modify it to make it more accessible to you.