Show simple item record

Healing and osseointegration of submerged microtextured oral implants

dc.contributor.authorOh, Tae-Juen_US
dc.contributor.authorYoon, Joongkyoen_US
dc.contributor.authorMeraw, Stephen J.en_US
dc.contributor.authorGiannobile, William V.en_US
dc.contributor.authorWang, Hom-Layen_US
dc.date.accessioned2010-06-01T20:43:57Z
dc.date.available2010-06-01T20:43:57Z
dc.date.issued2003-10en_US
dc.identifier.citationOh, Tae-Ju; Yoon, Joongkyo; Meraw, Stephen J . ; Giannobile, William V . ; Wang, Hom-Lay (2003). "Healing and osseointegration of submerged microtextured oral implants." Clinical Oral Implants Research 14(5): 643-650. <http://hdl.handle.net/2027.42/73835>en_US
dc.identifier.issn0905-7161en_US
dc.identifier.issn1600-0501en_US
dc.identifier.urihttps://hdl.handle.net/2027.42/73835
dc.identifier.urihttp://www.ncbi.nlm.nih.gov/sites/entrez?cmd=retrieve&db=pubmed&list_uids=12969369&dopt=citationen_US
dc.description.abstractThe success of dental implants is primarily dependent upon the degree of osseointegration or bone-to-implant contact (BIC), possibly facilitated by a roughened implant surface. This study was performed to histologically evaluate the nature of osseointegration and bone healing of submerged microtextured implants in eight dogs. Three months following tooth extraction in the posterior mandibulae, three microtextured submerged implants were placed in each quadrant. Block biopsies were harvested at 4 and 16 weeks (four dogs each) following surgery, and histologic preparation was performed. Histomorphometric analysis demonstrated that % BIC value increased marginally from 40% at 4 weeks to 48% at 16 weeks, without a statistically significant difference. The first bone-to-implant contact (f-BIC) at 16 weeks was significantly lower than the 4-week f-BIC (0.81 mm vs. 0.56 mm). In conclusion, this study found minimal change in BIC over time (from 4 to 16 weeks) in unloaded microtextured implants, while the mean f-BIC value significantly increased during this same observation period. To cite this article: Oh T-J, Yoon J, Merwa SJ, Giannobile WV, Wang H-L. Healing and osseointegration of submerged microtextured oral implants. Clin. Oral Impl. Res. 14 , 2003; 643–650en_US
dc.format.extent6557236 bytes
dc.format.extent3109 bytes
dc.format.mimetypeapplication/pdf
dc.format.mimetypetext/plain
dc.publisherMunksgaard International Publishersen_US
dc.publisherBlackwell Publishing Ltden_US
dc.rightsCopyright © Blackwell Munksgaard 2003en_US
dc.subject.otherBone Healingen_US
dc.subject.otherDental Implanten_US
dc.subject.otherOsseointegrationen_US
dc.subject.otherRoughened Implant Surfaceen_US
dc.titleHealing and osseointegration of submerged microtextured oral implantsen_US
dc.typeArticleen_US
dc.subject.hlbsecondlevelDentistryen_US
dc.subject.hlbtoplevelHealth Sciencesen_US
dc.description.peerreviewedPeer Revieweden_US
dc.identifier.pmid12969369en_US
dc.description.bitstreamurlhttp://deepblue.lib.umich.edu/bitstream/2027.42/73835/1/j.1600-0501.2003.00887.x.pdf
dc.identifier.doi10.1034/j.1600-0501.2003.00887.xen_US
dc.identifier.sourceClinical Oral Implants Researchen_US
dc.identifier.citedreferenceAbrahamsson, I., Berglundh, T., Moon, I. S. & Lindhe, J. ( 1999 ) Peri-implant tissues at submerged and non-submerged titanium implants. Journal of Clinical Periodontology 26: 600 – 607.en_US
dc.identifier.citedreferenceAdell, R., Lekholm, U., Rockler, B. & BrÅnemark, P. -I. ( 1981 ) A 15-year study of osseointegrated implants in the treatment of the edentulous jaw. International Journal of Oral Surgery 10: 387 – 416.en_US
dc.identifier.citedreferenceAlbrektsson, T. ( 1988 ) A multicenter report on osseointegrated oral implants. Journal of Prosthetic Dentistry 60: 75 – 84.en_US
dc.identifier.citedreferenceAlbrektsson, T., Zarb, G., Worthington, P. & Ericsson, R. A. ( 1986 ) The long-term efficacy of currently used dental implants: a review and proposed criteria of success. International Journal of Oral and Maxillofacial Implants 1: 11 – 25.en_US
dc.identifier.citedreferenceAlbreksson, et al. ( 1988 ).en_US
dc.identifier.citedreferenceBloebaum, R. D., Sanderson, C., McCarvill, S. & Campbell, P. ( 1989 ) Plastic slides in the preparation of implant and tissue for interface analysis. Journal of Histotechnology 12: 307 – 310.en_US
dc.identifier.citedreferenceBrÅnemark, P. I. ( 1985 ) Introduction to osseointegration. In: BrÅnemark, P. I., Zarb, G. & Albreksson, T., eds. Tissue-integrated prostheses. Oseeointegration in clinical dentistry, pp. 11 – 76. Chicago; Berlin: Quintessence Publishing Co.en_US
dc.identifier.citedreferenceBrÅnemark, P. I., Breine, U., Adell, R., Hansson, B. O., Linstrom, J. & Ohlsson, A. ( 1969 ) Intraossous anchorage of dental prostheses. I. Experimental studies. Scandinavian Journal of Plastic and Reconstructive Surgery 3: 81 – 100.en_US
dc.identifier.citedreferenceBuser, D., Mericske-Stern, R., Bernard, J. P., Behneke, A., Behneke, N., Hirt, H. P., Belser, U. C. & Lang, N. P. ( 1997 ) Long-term evaluation of non-submerged ITI implants Part 1: 8-year life table analysis of a prospective multi-center study with 2359 implants. Clinical Oral Implants Research 8: 161 – 172.en_US
dc.identifier.citedreferenceBuser, D., Mericske-Stern, R., Dula, K. & Lang, N. P. ( 1999 ) Clinical experience with one-stage, non-submerged dental implants. Advances in Dental Research 13: 153 – 161.en_US
dc.identifier.citedreferenceBuser, D., Schenk, R. K., Steinmann, S., Fiorellini, J. P., Fox, C. H. & Stich, H. ( 1991 ) Influence of surface characteristics on bone integration of titanium implants. A histomorphometric study in miniature pigs. Journal of Biomedical Materials Research 25: 889 – 902.en_US
dc.identifier.citedreferenceCochran, D. L. ( 1999 ) A comparison of endosseous dental implant surfaces. Journal of Periodontology 70: 1523 – 1539.en_US
dc.identifier.citedreferenceCochran, D. L. ( 2000 ) The scientific basis for and clinical experiences with Straumann implants including the ITI ® dental implant system: a consensus report. Clinical Oral Implants Research 11: 33 – 58.en_US
dc.identifier.citedreferenceCochran, D. L., Scheik, R. K., Lussi, A., Higginbottom, F. L. & Buser, D. ( 1998 ) Bone response to unloaded and loaded titanium implants with a sandblasted and acid-etched surface. A histometric study in the canine mandibule. Journal of Biomedical Materials Research 40: 1 – 11.en_US
dc.identifier.citedreferenceEricsson, I., Johansson, C. B., Bystedt, H. & Norton, M. R. ( 1994 ) A histomorphometric evaluation of bone-to–implant contact on machine-prepared and roughened titanium dental implants. A pilot study in the dog. Clinical Oral Implants Research 5: 202 – 206.en_US
dc.identifier.citedreferenceGiannobile, W. V., Ryan, S., Shih, M. S., Su, D. L., Kaplan, P. L. & Chan, T. C. ( 1998 ) Recombinant human osteogenic protein-1 (OP-1) stimulates periodontal wound healing in class III furcation defects. Journal of Periodontology 69: 129 – 137.en_US
dc.identifier.citedreferenceGotfredsen, K., Berglundh, T. & Lindhe, J. ( 2001a ) Bone reactions adjacent to titanium implants subjected to static load. A study in the dog (I). Clinical Oral Implants Research 12: 1 – 8.en_US
dc.identifier.citedreferenceGotfredsen, K., Berglundh, T. & Lindhe, J. ( 2001b ) Bone reactions adjacent to titanium implants with different surface characteristics subjected to static load. A study in the dog (II). Clinical Oral Implants Research 12: 196 – 201.en_US
dc.identifier.citedreferenceGotfredsen, K., Wennerberg, A., Johansson, C., Skovgaard, L. T. & Hjorting-Hansen, E. ( 1995 ) Anchorage of TiO2-blasted, HA-coated, and machined implants: An experimental study with rabbits. Journal of Biomedical Materials Research 29: 1223 – 1231.en_US
dc.identifier.citedreferenceHale, T. M., Boretsky, B. B., Scheidt, M. J., McQuade, M. J., Strong, S. L. & van Dyke, T. E. ( 1991 ) Evaluation of titanium dental implant osseointegration in posterior edentulous areas of micro swine. Journal of Oral Implantology 17: 118 – 124.en_US
dc.identifier.citedreferenceHenry, P. J., Tan, A. E., Leavy, J., Johansson, C. B. & Albrektsson, T. ( 1997 ) Tissue regeneration in bony defects adjacent to immediately loaded titanium implants placed into extraction sockets: a study in dogs. International Journal of Oral and Maxillofacial Implants 12: 758 – 766.en_US
dc.identifier.citedreferenceJohansson, C. B. & Albrektsson, T. ( 1991 ) A removal torque and histomorphometric study of commercially pure nobium and titanium implant in rabbit bone. Clinical Oral Implants Research 2: 24 – 29.en_US
dc.identifier.citedreferenceKohal, R. J., De laRossa, M., Patrick, D., Hurzeler, M. B. & Caffesse, R. G. ( 1999 ) Clinical and histologic evaluation of submerged and nonsubmerged hydroxyapatite-coated implants: a preliminary study in dogs. International Journal of Oral and Maxilofacial Implants 14: 824 – 834.en_US
dc.identifier.citedreferenceOh, T. -J., Yoon, J., Misch, C. E. & Wang, H. L. ( 2002 ) The causes of early implant bone loss: Myth or science? Journal of Periodontology 73: 322 – 333.en_US
dc.identifier.citedreferenceOh, T. -J., Meraw, S. J., Lee, E. -J., Giannobile, W. V. & Wang, H. L. ( 2003 ) Comparative analysis of collagen membranes for the treatment of implant dehiscence defects. Clinical Oral Implants Research 14: 80 – 90.en_US
dc.identifier.citedreferencePebe, P., Barbot, R., Trinidad, J., Pesquera, A., Lucente, J., Nishimura, R. & Nasr, H. ( 1997 ) Countertorque testing and histomorphometric analysis of various implant surfaces in canines: a pilot study. Implant Dentistry 6: 259 – 265.en_US
dc.identifier.citedreferencePiattelli, A., Corigliano, M., Scarano, A., Costigliola, G. & Paolantonio, M. ( 1998 ) Immediate loading of titanium plasma-sprayed implants: an histologic analysis in monkeys. Journal of Periodontology 69: 321 – 327.en_US
dc.identifier.citedreferenceSanderson, C. & Kitabayashi, L. R. ( 1994 ) Parallel experiences of two different laboratories with the initiator Perkadox 16 for polymerization of methylmethacrylate. Journal of Histotechnology 17: 343 – 348.en_US
dc.identifier.citedreferenceSchroeder, A., van der Zypen, E., Strich, H. & Sutter, F. ( 1981 ) The reactions of bone, connective tissue, and epithelium to endosteal implants with titanium-sprayed surfaces. Journal of Maxillofacial Surgery 9: 15 – 25.en_US
dc.identifier.citedreferenceTrisi, P., Rao, W. & Rebaudi, A. ( 1999 ) A histometric comparison of smooth and rough titanium implants in human low-density jawbone. International Journal of Oral and Maxilofacial Implants 14: 689 – 698.en_US
dc.identifier.citedreferenceWeber, H. P., Crohin, C. C. & Fiorellini, J. P. ( 2000 ) A 5-year prospective clinical and radiologic study of non-submerged dental implants. Clinical Oral Implants Research 11: 144 – 153.en_US
dc.identifier.citedreferenceWennerberg, A., Albrektsson, T., Andersson, B. & Krol, J. J. ( 1995 ) A histomorphometric and removal torque study of screw-shaped titanium implants with three different surface topographies. Clinical Oral Implants Research 6: 24 – 30.en_US
dc.identifier.citedreferenceWennerberg, A., Hallgren, C., Johansson, C. & Daneelli, S. ( 1998 ) A histomorphometric evaluation of screw-shaped implants each prepared with two surface roughness. Clinical Oral Implants Research 9: 11 – 19.en_US
dc.owningcollnameInterdisciplinary and Peer-Reviewed


Files in this item

Show simple item record

Remediation of Harmful Language

The University of Michigan Library aims to describe library materials in a way that respects the people and communities who create, use, and are represented in our collections. Report harmful or offensive language in catalog records, finding aids, or elsewhere in our collections anonymously through our metadata feedback form. More information at Remediation of Harmful Language.

Accessibility

If you are unable to use this file in its current format, please select the Contact Us link and we can modify it to make it more accessible to you.