Show simple item record

The Bin Area Method: A Computationally Efficient Technique for Analysis of Ventricular and Atrial Intracardiac Electrograms

dc.contributor.authorThrone, Robert D.en_US
dc.contributor.authorJenkins, Janice M.en_US
dc.contributor.authorDicarlo, Lorenzo A.en_US
dc.date.accessioned2010-06-01T21:51:52Z
dc.date.available2010-06-01T21:51:52Z
dc.date.issued1990-10en_US
dc.identifier.citationTHRONE, ROBERT D.; JENKINS, JANICE M.; DICARLO, LORENZO A. (1990). "The Bin Area Method: A Computationally Efficient Technique for Analysis of Ventricular and Atrial Intracardiac Electrograms." Pacing and Clinical Electrophysiology 13(10): 1286-1297. <http://hdl.handle.net/2027.42/74901>en_US
dc.identifier.issn0147-8389en_US
dc.identifier.issn1540-8159en_US
dc.identifier.urihttps://hdl.handle.net/2027.42/74901
dc.identifier.urihttp://www.ncbi.nlm.nih.gov/sites/entrez?cmd=retrieve&db=pubmed&list_uids=1701544&dopt=citationen_US
dc.format.extent4480251 bytes
dc.format.extent3109 bytes
dc.format.mimetypeapplication/pdf
dc.format.mimetypetext/plain
dc.publisherBlackwell Publishing Ltden_US
dc.rights1990 Official journal of the International Cardiac Pacing and Electrophysiology Societyen_US
dc.subject.otherPacemaker-mediated Tachycardiaen_US
dc.subject.otherDual-chamber Pacemakeren_US
dc.subject.otherTachycardiaen_US
dc.subject.otherTachyarrhythmiaen_US
dc.subject.otherRetrograde Atrial Activationen_US
dc.titleThe Bin Area Method: A Computationally Efficient Technique for Analysis of Ventricular and Atrial Intracardiac Electrogramsen_US
dc.typeArticleen_US
dc.subject.hlbsecondlevelPhysiologyen_US
dc.subject.hlbtoplevelHealth Sciencesen_US
dc.description.peerreviewedPeer Revieweden_US
dc.contributor.affiliationumFrom the Medical Computing Laboratory, Department of Electrical Engineering and Computer Science, University of Michigan, Ann Arbor, Michiganen_US
dc.contributor.affiliationum* Cardiac Electrophysiology Laboratory, St. Joseph Mercy Hospital of the Catherine McAuley Health Center, Ann Arbor, Michiganen_US
dc.identifier.pmid1701544en_US
dc.description.bitstreamurlhttp://deepblue.lib.umich.edu/bitstream/2027.42/74901/1/j.1540-8159.1990.tb02028.x.pdf
dc.identifier.doi10.1111/j.1540-8159.1990.tb02028.xen_US
dc.identifier.sourcePacing and Clinical Electrophysiologyen_US
dc.identifier.citedreferenceEcht DS, Armstrong K, Schmidt P, et al. Clinical experience, complications, and survival in 70 patients with the automatic implantable cardioverter/defibrillator. (abstract) Circulation 1985; 71: 289.en_US
dc.identifier.citedreferenceManz M, Gerckens U, Luderitz B. Erroneous discharge from an implanted automatic cardioverter/defibrillator during supraventricular tachyarrhythmia-induced ventricular fibrillation. Am J Cardiol 1986; 7: 343.en_US
dc.identifier.citedreferencePlatia EV, Griffith LSC, Reid PR, et al. Complications with the automatic implantable cardioverter defibrillator. (abstract) J Am Coll Cardiol 1986; 2: 200.en_US
dc.identifier.citedreferenceGabry MD, Brodman R. Johnston D, et al. Automatic implantable cardioverter-defibrillalor: Patient survival, battery longevity, and shock delivery analysis. J Am Coll Cardiol 1987; 9: 1349 – 1356.en_US
dc.identifier.citedreferencePodczeck A, Frohnor K, Heif CH, et al. Termination of life-threatening ventricular tachyarrhythmias by the automatic implantable cardioverter defibrillator (AICD). (abstract) PACE 1989; 12: 1256.en_US
dc.identifier.citedreferenceVeltri E, Mower M, Aarons D, et al. Automatic implantable cardioverter-defibrillator: Comparison of patients with and without discharge, ( abstract ) Circulation 1989; 80: 530.en_US
dc.identifier.citedreferenceSteinberg JS, Sugalski JS, Haratonic K. Cardiac rhythm precipitating automatic-implantable cardioverter defibrillator discharge in outpatients: Observations from transtelephonic recordings, ( abstract ) Circulation 1989; 80: 530.en_US
dc.identifier.citedreferenceMcAlister H, Klementowicz PT, Calderon EM, et al. Atrial electrogram analysis: Antegrade vs retrograde. PACE 1988; 11: 1703 – 1707.en_US
dc.identifier.citedreferencePannizzo F, Furman S. Automatic discrimination of retrograde P waves for dual chamber pacemakers, ( abstract ) J Am Coll Cardiol 1985; 5: 393.en_US
dc.identifier.citedreferencePannizzo F, Amikam S, Bagwell P, et al. Discrimination of antegrade and retrograde atrial depolarization by electrogram analysis. Am Heart J 1986; 112: 780 – 786.en_US
dc.identifier.citedreferenceBernheim C, Markewitz A, Kemes BH. Can reprogramming of atrial sensitivity avoid an endless loop tachycardia ? (abstract) PACE 1986; 4: 18.en_US
dc.identifier.citedreferenceMcAlister H, Adelson R, Calderon E, et al. Atrial electrogram analysis: Antegrade vs retrograde, ( abstract ) PACE 1988; 11: 818.en_US
dc.identifier.citedreferenceTomaselli G, Nielsen A, Finke W, et al. Morphologic differences of the endocardial electrogram in beats of sinus and ventricular origin. PACE 1988; 11: 254 – 262.en_US
dc.identifier.citedreferenceLangberg J, Gibb W, Auslander D, et al. Identification of ventricular tachycardia with use of the morphology of the endocardial electrogram. Circulation 1988; 77: 1363 – 1369.en_US
dc.identifier.citedreferenceTimmis G, Westveer D, Bakafyar D, et al. Discrimination of antegrade from retrograde atrial electrograms for physiologic pacing. PACE 1988; 11: 130 – 140.en_US
dc.identifier.citedreferenceLin D, DiCarlo LA, Jenkins JM. Identification of ventricular tachycardia using intracavitary ventricular electrograms; Analysis of time and frequency domain patterns. PACE 1988; 11: 1592 – 1606.en_US
dc.identifier.citedreferencePannizzo F, Furman S. Frequency spectra of ventricular tachycardia and sinus rhythm in human intracardiac electrograms-application to tachycardia detection for cardiac pacemakers. IEEE Trans Biomed Eng 1988; 35: 421 – 425.en_US
dc.identifier.citedreferenceTomaselli G, Gibb W, Langberg I, et al. In vivo testing of a morphology based approach to cardiac rhythm identification, ( abstract ) Circulation 1987: 76: 1116.en_US
dc.identifier.citedreferenceThrone RD, DiCarlo LA, Jenkins JM, et al. Paroxysmal bundle branch block of supraventricular origin: A possible source of misdiagnosis in detecting ventricular tachycardia using time domain analyses of intraventricular electrograms. PACE 1990; 13: 453 – 468.en_US
dc.identifier.citedreferenceWainwright RJ, Davies DW, Tooley MA. Ideal atrial lead positioning to detect retrograde atrial depolarization by digitization and slope analysis of the atrial electrogram. PACE 1984: 7: 1152 – 1158.en_US
dc.identifier.citedreferenceDavies DW, Wainwright RJ, Tooley MA, et al. Electrogram recognition by digital analysis: Relevance to pacemaker arrhythmia control ? (abstract) J Am Coll Cardiol 1985; 5: 507.en_US
dc.identifier.citedreferenceDavies DW, Wainwright RJ, Tooley MA. et al. Detection of pathological tachycardia by analysis of electrogram morphology. PACE 1986; 9: 200 – 208.en_US
dc.identifier.citedreferenceDavies DW, Tooley MA. Cochrane T, et al. Realtime tachycardia diagnosis using morphological analysis of electrograms. ( abstract ) PACE: 1987; 10: 998.en_US
dc.identifier.citedreferenceDiCarlo L, Lin D, and Jenkins JM. Analysis of time and frequency domain patterns to distinguish ventricular tachycardia from sinus rhythm using endocardial electrograms. Circulation 1987; 76: 280.( Abstract ).en_US
dc.identifier.citedreferenceThrone RD, Fenkins JM, Winston SA, et al. Derivative area method: A new technique for detecting ventricular tachycardia, ( abstract ) Circulation 1989; 80: 658.en_US
dc.identifier.citedreferenceThrone RD, Jenkins JM, Winston SA, et al. Discrimination of retograde from anterograde atrial activation using intracardiac electrogram waveform analysis. PACE 1989; 12: 1622 – 1630.en_US
dc.owningcollnameInterdisciplinary and Peer-Reviewed


Files in this item

Show simple item record

Remediation of Harmful Language

The University of Michigan Library aims to describe library materials in a way that respects the people and communities who create, use, and are represented in our collections. Report harmful or offensive language in catalog records, finding aids, or elsewhere in our collections anonymously through our metadata feedback form. More information at Remediation of Harmful Language.

Accessibility

If you are unable to use this file in its current format, please select the Contact Us link and we can modify it to make it more accessible to you.