Show simple item record

In Vivo Neurochemical Monitoring with High Temporal and Spatial Resolution using Segmented Flow Microfluidics.

dc.contributor.authorWang, Mengen_US
dc.date.accessioned2011-06-10T18:18:21Z
dc.date.availableNO_RESTRICTIONen_US
dc.date.available2011-06-10T18:18:21Z
dc.date.issued2011en_US
dc.date.submitted2011en_US
dc.identifier.urihttps://hdl.handle.net/2027.42/84522
dc.description.abstractMonitoring the concentration dynamics of neurochemicals in the brain is a key tool in the effort to understand brain function, diseases, and treatments. A versatile and effective approach for in vivo monitoring of chemical messages is to couple sampling methods, such as microdialysis, to analytical measurements. Although this approach has proven invaluable, it is limited by poor temporal and spatial resolution. Temporal resolution is limited to about 60 s by the dispersion of sampled concentration zones during transportation. Spatial resolution is limited by the size of microdialysis probes which are typically 200 to 500 micrometer diameter and 1-4 mm long. As a result, some rapid chemical changes cannot be detected and the method cannot be used to probe smaller brain nuclei. To address the temporal resolution problem, a microfluidic device was developed that segmented a sample stream into plugs separated by fluorinated oil to prevent temporal distortion during transport. To quantify the chemical contents of the plugs, systems were developed for enzymatic and electrophoretic analysis. For enzyme assay, reagents were added to the plugs as they were formed and detected by fluorescence. For electrophoresis, a microfluidic device was developed that extracted plugs from the segmented flow stream and then injected them into a narrow channel for electrophoretic separation. The sampling and analysis systems allowed temporal resolution as good as 2 s. Alternatively, a capillary-based electrophoresis system could also be used to analyze dialysate plugs through a simple interface with 14 s on-line temporal resolution and robust performances. To address the spatial resolution problem, the segmented flow analysis approach was coupled with miniauturized microdialysis probe with 0.5 mm sampling length. This system improved spatial resolution 2-8 fold over regular microdialysis while maintaining temporal resolution of 10-15 seconds. Dynamics of glucose and neuroactive amino acids were monitored in vivo with both anesthetized and freely-moving rats during pharmacological manipulations. These applications not only validated the robustness of this system, but also revealed different releasing pattern of taurine upon long term and short puffs of potassium infusion due to unprecedented spatial and temporal resolution it could offer.en_US
dc.language.isoen_USen_US
dc.subjectMicrodialysisen_US
dc.subjectIn Vivo Monitoringen_US
dc.subjectCapillary Electrophoresisen_US
dc.subjectMicrofluidicsen_US
dc.subjectTemporal Resolutionen_US
dc.subjectSpatial Resolutionen_US
dc.titleIn Vivo Neurochemical Monitoring with High Temporal and Spatial Resolution using Segmented Flow Microfluidics.en_US
dc.typeThesisen_US
dc.description.thesisdegreenamePhDen_US
dc.description.thesisdegreedisciplineChemistryen_US
dc.description.thesisdegreegrantorUniversity of Michigan, Horace H. Rackham School of Graduate Studiesen_US
dc.contributor.committeememberKennedy, Robert T.en_US
dc.contributor.committeememberBurns, Mark A.en_US
dc.contributor.committeememberChen, Zhanen_US
dc.contributor.committeememberGnegy, Margaret E.en_US
dc.contributor.committeememberHakansson, Kristina I.en_US
dc.subject.hlbsecondlevelChemistryen_US
dc.subject.hlbtoplevelScienceen_US
dc.description.bitstreamurlhttp://deepblue.lib.umich.edu/bitstream/2027.42/84522/1/mengwang_1.pdf
dc.owningcollnameDissertations and Theses (Ph.D. and Master's)


Files in this item

Show simple item record

Remediation of Harmful Language

The University of Michigan Library aims to describe library materials in a way that respects the people and communities who create, use, and are represented in our collections. Report harmful or offensive language in catalog records, finding aids, or elsewhere in our collections anonymously through our metadata feedback form. More information at Remediation of Harmful Language.

Accessibility

If you are unable to use this file in its current format, please select the Contact Us link and we can modify it to make it more accessible to you.