Show simple item record

Edge-Preserving Tomographic Reconstruction with Nonlocal Regularization

dc.contributor.authorYu, Daniel F.en_US
dc.contributor.authorFessler, Jeffrey A.en_US
dc.date.accessioned2011-08-18T18:21:18Z
dc.date.available2011-08-18T18:21:18Z
dc.date.issued2002-02en_US
dc.identifier.citationYu, D.F.; Fessler, J.A. (2002). "Edge-Preserving Tomographic Reconstruction with Nonlocal Regularization." IEEE Transactions on Medical Imaging 21(2): 159-173. <http://hdl.handle.net/2027.42/85989>en_US
dc.identifier.issn0278-0062en_US
dc.identifier.urihttps://hdl.handle.net/2027.42/85989
dc.description.abstractTomographic image reconstruction using statistical methods can provide more accurate system modeling, statistical models, and physical constraints than the conventional filtered backprojection (FBP) method. Because of the ill posedness of the reconstruction problem, a roughness penalty is often imposed on the solution to control noise. To avoid smoothing of edges, which are important image attributes, various edge-preserving regularization methods have been proposed. Most of these schemes rely on information from local neighborhoods to determine the presence of edges. In this paper, we propose a cost function that incorporates nonlocal boundary information into the regularization method. We use an alternating minimization algorithm with deterministic annealing to minimize the proposed cost function, jointly estimating region boundaries and object pixel values. We apply variational techniques implemented using level-sets methods to update the boundary estimates; then, using the most recent boundary estimate, we minimize a space-variant quadratic cost function to update the image estimate. For the positron emission tomography transmission reconstruction application, we compare the bias-variance tradeoff of this method with that of a "conventional" penalized-likelihood algorithm with local Huber roughness penalty.en_US
dc.publisherIEEEen_US
dc.titleEdge-Preserving Tomographic Reconstruction with Nonlocal Regularizationen_US
dc.typeArticleen_US
dc.subject.hlbsecondlevelBiomedical Engineeringen_US
dc.subject.hlbtoplevelEngineeringen_US
dc.description.peerreviewedPeer Revieweden_US
dc.contributor.affiliationumElectrical Engineering and Computer Science Department.en_US
dc.identifier.pmid11929103en_US
dc.description.bitstreamurlhttp://deepblue.lib.umich.edu/bitstream/2027.42/85989/1/Fessler73.pdf
dc.identifier.doi10.1109/42.993134en_US
dc.identifier.sourceIEEE Transactions on Medical Imagingen_US
dc.owningcollnameElectrical Engineering and Computer Science, Department of (EECS)


Files in this item

Show simple item record

Remediation of Harmful Language

The University of Michigan Library aims to describe library materials in a way that respects the people and communities who create, use, and are represented in our collections. Report harmful or offensive language in catalog records, finding aids, or elsewhere in our collections anonymously through our metadata feedback form. More information at Remediation of Harmful Language.

Accessibility

If you are unable to use this file in its current format, please select the Contact Us link and we can modify it to make it more accessible to you.