Show simple item record

Improved Modeling of System Response in List Mode EM Reconstruction of Compton Scatter Camera Images

dc.contributor.authorWilderman, S. J.en_US
dc.contributor.authorFessler, Jeffrey A.en_US
dc.contributor.authorClinthorne, N. H.en_US
dc.contributor.authorLeBlanc, J. W.en_US
dc.contributor.authorRogers, W. L.en_US
dc.date.accessioned2011-08-18T18:21:24Z
dc.date.available2011-08-18T18:21:24Z
dc.date.issued2001-02en_US
dc.identifier.citationWilderman, S.J.; Fessler, J.A.; Clinthorne, N.H.; LeBlanc, J.W.; Rogers, W.L. (2001). "Improved Modeling of System Response in List Mode EM Reconstruction of Compton Scatter Camera Images." IEEE Transactions on Nuclear Science 48(1): 111-116. <http://hdl.handle.net/2027.42/86026>en_US
dc.identifier.issn0018-9499en_US
dc.identifier.urihttps://hdl.handle.net/2027.42/86026
dc.description.abstractAn improved List Mode EM method for reconstructing Compton scattering camera images has been developed. First, an approximate method for computation of the spatial variation in the detector sensitivity has been derived and validated by Monte Carlo computation. A technique for estimating the relative weight of system matrix coefficients for each gamma in the list has also been employed, as has a method for determining the relative probabilities of emission having come from pixels tallied in each list-mode back-projection. Finally, a technique has been developed for modeling the effects of Doppler broadening and finite detector energy resolution on the relative weights for pixels neighbor to those intersected by the back-projection, based on values for the FWHM of the spread in the cone angle computed by Monte Carlo. Memory issues typically associated with list mode reconstruction are circumvented by storing only a list of the pixels intersected by the back-projections, and computing the weights of the neighboring pixels at each iteration step. Reconstructions have been performed on experimental data for both point and distributed sourcesen_US
dc.publisherIEEEen_US
dc.titleImproved Modeling of System Response in List Mode EM Reconstruction of Compton Scatter Camera Imagesen_US
dc.typeArticleen_US
dc.subject.hlbsecondlevelBiomedical Engineeringen_US
dc.subject.hlbtoplevelEngineeringen_US
dc.description.peerreviewedPeer Revieweden_US
dc.contributor.affiliationumDepartment of Nuclear Engineering and Radiologic Sciences. Division of Nuclear Medicine. Department of Biomedical Engineerinen_US
dc.description.bitstreamurlhttp://deepblue.lib.umich.edu/bitstream/2027.42/86026/1/Fessler77.pdf
dc.identifier.doi10.1109/23.910840en_US
dc.identifier.sourceIEEE Transactions on Nuclear Scienceen_US
dc.owningcollnameElectrical Engineering and Computer Science, Department of (EECS)


Files in this item

Show simple item record

Remediation of Harmful Language

The University of Michigan Library aims to describe library materials in a way that respects the people and communities who create, use, and are represented in our collections. Report harmful or offensive language in catalog records, finding aids, or elsewhere in our collections anonymously through our metadata feedback form. More information at Remediation of Harmful Language.