Time‐ and Frequency‐Domain Characteristics of Atrial Electrograms During Sinus Rhythm and Atrial Fibrillation
dc.contributor.author | Chang, Sheng‐hsiung | en_US |
dc.contributor.author | Ulfarsson, Magnus O. | en_US |
dc.contributor.author | Chugh, Aman | en_US |
dc.contributor.author | Yoshida, Kentaro | en_US |
dc.contributor.author | Jongnarangsin, Krit | en_US |
dc.contributor.author | Crawford, Thomas | en_US |
dc.contributor.author | Good, Eric D. | en_US |
dc.contributor.author | Pelosi, Frank Jr. | en_US |
dc.contributor.author | Bogun, Frank M. | en_US |
dc.contributor.author | Morady, Fred | en_US |
dc.contributor.author | Oral, Hakan | en_US |
dc.date.accessioned | 2011-11-10T15:37:27Z | |
dc.date.available | 2012-10-01T18:34:37Z | en_US |
dc.date.issued | 2011-08 | en_US |
dc.identifier.citation | Chang, Sheng‐hsiung ; Ulfarsson, Magnus ; Chugh, Aman ; Yoshida, Kentaro ; Jongnarangsin, Krit ; Crawford, Thomas ; Good, Eric ; Pelosi, Frank ; Bogun, Frank ; Morady, Fred ; Oral, Hakan (2011). "Timeâ and Frequencyâ Domain Characteristics of Atrial Electrograms During Sinus Rhythm and Atrial Fibrillation." Journal of Cardiovascular Electrophysiology 22(8). <http://hdl.handle.net/2027.42/87064> | en_US |
dc.identifier.issn | 1045-3873 | en_US |
dc.identifier.issn | 1540-8167 | en_US |
dc.identifier.uri | https://hdl.handle.net/2027.42/87064 | |
dc.publisher | Blackwell Publishing Inc | en_US |
dc.publisher | Wiley Periodicals, Inc. | en_US |
dc.subject.other | Atrial Fibrillation | en_US |
dc.subject.other | Complex Fractionated Atrial Electrograms | en_US |
dc.subject.other | Catheter Ablation | en_US |
dc.subject.other | Spectral Analysis | en_US |
dc.subject.other | Dominant Frequency | en_US |
dc.title | Time‐ and Frequency‐Domain Characteristics of Atrial Electrograms During Sinus Rhythm and Atrial Fibrillation | en_US |
dc.type | Article | en_US |
dc.rights.robots | IndexNoFollow | en_US |
dc.subject.hlbsecondlevel | Internal Medicine and Specialties | en_US |
dc.subject.hlbsecondlevel | Physiology | en_US |
dc.subject.hlbtoplevel | Health Sciences | en_US |
dc.description.peerreviewed | Peer Reviewed | en_US |
dc.contributor.affiliationum | Division of Cardiovascular Medicine, University of Michigan, Ann Arbor, Michigan | en_US |
dc.contributor.affiliationother | Department of Electrical and Computer Engineering, University of Iceland, Reykjavik, Iceland | en_US |
dc.description.bitstreamurl | http://deepblue.lib.umich.edu/bitstream/2027.42/87064/1/j.1540-8167.2011.02022.x.pdf | |
dc.identifier.doi | 10.1111/j.1540-8167.2011.02022.x | en_US |
dc.identifier.source | Journal of Cardiovascular Electrophysiology | en_US |
dc.identifier.citedreference | Nademanee K, McKenzie J, Kosar E, Schwab M, Sunsaneewitayakul B, Vasavakul T, Khunnawat C, Ngarmukos T: A new approach for catheter ablation of atrial fibrillation: Mapping of the electrophysiologic substrate. J Am Coll Cardiol 2004; 43: 2044 ‐ 2053. | en_US |
dc.identifier.citedreference | Oral H, Chugh A, Good E, Wimmer A, Dey S, Gadeela N, Sankaran S, Crawford T, Sarrazin JF, Kuhne M, Chalfoun N, Wells D, Frederick M, Fortino J, Benloucif‐Moore S, Jongnarangsin K, Pelosi F Jr, Bogun F, Morady F: Radiofrequency catheter ablation of chronic atrial fibrillation guided by complex electrograms. Circulation 2007; 115: 2606 ‐ 2612. | en_US |
dc.identifier.citedreference | Haissaguerre M, Sanders P, Hocini M, Takahashi Y, Rotter M, Sacher F, Rostock T, Hsu LF, Bordachar P, Reuter S, Roudaut R, Clementy J, Jais P: Catheter ablation of long‐lasting persistent atrial fibrillation: Critical structures for termination. J Cardiovasc Electrophysiol 2005; 16: 1125 ‐ 1137. | en_US |
dc.identifier.citedreference | Pachon MJ, Pachon ME, Pachon MJ, Lobo TJ, Pachon MZ, Vargas RN, Pachon DQ, Lopez MF, Jatene AD: A new treatment for atrial fibrillation based on spectral analysis to guide the catheter rf‐ablation. Europace 2004; 6: 590 ‐ 601. | en_US |
dc.identifier.citedreference | Konings KT, Smeets JL, Penn OC, Wellens HJ, Allessie MA: Configuration of unipolar atrial electrograms during electrically induced atrial fibrillation in humans. Circulation 1997; 95: 1231 ‐ 1241. | en_US |
dc.identifier.citedreference | Kalifa J, Tanaka K, Zaitsev AV, Warren M, Vaidyanathan R, Auerbach D, Pandit S, Vikstrom KL, Ploutz‐Snyder R, Talkachou A, Atienza F, Guiraudon G, Jalife J, Berenfeld O: Mechanisms of wave fractionation at boundaries of high‐frequency excitation in the posterior left atrium of the isolated sheep heart during atrial fibrillation. Circulation 2006; 113: 626 ‐ 633. | en_US |
dc.identifier.citedreference | Lellouche N, Buch E, Celigoj A, Siegerman C, Cesario D, De Diego C, Mahajan A, Boyle NG, Wiener I, Garfinkel A, Shivkumar K: Functional characterization of atrial electrograms in sinus rhythm delineates sites of parasympathetic innervation in patients with paroxysmal atrial fibrillation. J Am Coll Cardiol 2007; 50: 1324 ‐ 1331. | en_US |
dc.identifier.citedreference | Lin J, Scherlag BJ, Zhou J, Lu Z, Patterson E, Jackman WM, Lazzara R, Po SS: Autonomic mechanism to explain complex fractionated atrial electrograms (cfae). J Cardiovasc Electrophysiol 2007; 18: 1197 ‐ 1205. | en_US |
dc.identifier.citedreference | Ho SY, Anderson RH, Sanchez‐Quintana D: Atrial structure and fibres: Morphologic bases of atrial conduction. Cardiovasc Res 2002; 54: 325 ‐ 336. | en_US |
dc.identifier.citedreference | Yoshida K, Ulfarsson M, Tada H, Chugh A, Good E, Kuhne M, Crawford T, Sarrazin JF, Chalfoun N, Wells D, Jongnarangsin K, Pelosi F Jr, Bogun F, Morady F, Oral H: Complex electrograms within the coronary sinus: Time‐ and frequency‐domain characteristics, effects of antral pulmonary vein isolation, and relationship to clinical outcome in patients with paroxysmal and persistent atrial fibrillation. J Cardiovasc Electrophysiol 2008; 19: 1017 ‐ 1023. | en_US |
dc.identifier.citedreference | Lemola K, Ting M, Gupta P, Anker JN, Chugh A, Good E, Reich S, Tschopp D, Igic P, Elmouchi D, Jongnarangsin K, Bogun F, Pelosi F Jr, Morady F, Oral H: Effects of two different catheter ablation techniques on spectral characteristics of atrial fibrillation. J Am Coll Cardiol 2006; 48: 340 ‐ 348. | en_US |
dc.identifier.citedreference | Saito T, Waki K, Becker AE: Left atrial myocardial extension onto pulmonary veins in humans: Anatomic observations relevant for atrial arrhythmias. J Cardiovasc Electrophysiol 2000; 11: 888 ‐ 894. | en_US |
dc.identifier.citedreference | Yamazaki M, Vaquero LM, Hou L, Campbell K, Zlochiver S, Klos M, Mironov S, Berenfeld O, Honjo H, Kodama I, Jalife J, Kalifa J: Mechanisms of stretch‐induced atrial fibrillation in the presence and the absence of adrenocholinergic stimulation: Interplay between rotors and focal discharges. Heart Rhythm 2009; 6: 1009 ‐ 1017. | en_US |
dc.identifier.citedreference | Nof E, Burashnikov A, Antzelevitch C: Cellular basis for atrial fibrillation in an experimental model of short qt1: Implications for a pharmacological approach to therapy. Heart Rhythm 2010; 7: 251 ‐ 257. | en_US |
dc.identifier.citedreference | Morady F, Nelson SD, Kou WH, Pratley R, Schmaltz S, De Buitleir M, Halter JB: Electrophysiologic effects of epinephrine in humans. J Am Coll Cardiol 1988; 11: 1235 ‐ 1244. | en_US |
dc.identifier.citedreference | Rostock T, Rotter M, Sanders P, Takahashi Y, Jais P, Hocini M, Hsu LF, Sacher F, Clementy J, Haissaguerre M: High‐density activation mapping of fractionated electrograms in the atria of patients with paroxysmal atrial fibrillation. Heart Rhythm 2006; 3: 27 ‐ 34. | en_US |
dc.owningcollname | Interdisciplinary and Peer-Reviewed |
Files in this item
Remediation of Harmful Language
The University of Michigan Library aims to describe library materials in a way that respects the people and communities who create, use, and are represented in our collections. Report harmful or offensive language in catalog records, finding aids, or elsewhere in our collections anonymously through our metadata feedback form. More information at Remediation of Harmful Language.
Accessibility
If you are unable to use this file in its current format, please select the Contact Us link and we can modify it to make it more accessible to you.