Diffractometer‐Control Software For Bragg‐Rod Measurements
dc.contributor.author | Yacoby, Y. | en_US |
dc.contributor.author | Walko, D. A. | en_US |
dc.contributor.author | Brewe, D. | en_US |
dc.contributor.author | Bretschneider, M. | en_US |
dc.contributor.author | Sowwan, M. | en_US |
dc.contributor.author | Clarke, Roy | en_US |
dc.contributor.author | Pindak, Ron | en_US |
dc.contributor.author | Stern, E. A. | en_US |
dc.date.accessioned | 2011-11-15T16:05:53Z | |
dc.date.available | 2011-11-15T16:05:53Z | |
dc.date.issued | 2004-05-12 | en_US |
dc.identifier.citation | Yacoby, Y.; Walko, D. A.; Brewe, D.; Bretschneider, M.; Sowwan, M.; Clarke, R.; Pindak, R.; Stern, E. A. (2004). "Diffractometer‐Control Software For Bragg‐Rod Measurements." AIP Conference Proceedings 705(1): 1221-1224. <http://hdl.handle.net/2027.42/87660> | en_US |
dc.identifier.other | APCPCS-705-1 | en_US |
dc.identifier.uri | https://hdl.handle.net/2027.42/87660 | |
dc.description.abstract | We present Generalized Diffractometer Control (gdc), a diffractometer‐control software package developed specifically for high‐precision measurements of Bragg rods; we discuss its features and analyze its performance in data collection. gdc, implemented at several APS beamlines, controls a six‐circle diffractometer in either Eulerian or kappa geometry, yet does not assume a mechanically ideal diffractometer; instead, the measured directions of the diffractometer axes (and the direction of the incident beam) are input parameters. The Labview‐based program features a graphical interface, making it straightforward to find all the commands and operations. Other features include optimized scans along Bragg rods, straightforward background subtraction, and extensive sets of pseudomotors. © 2004 American Institute of Physics | en_US |
dc.publisher | The American Institute of Physics | en_US |
dc.rights | © The American Institute of Physics | en_US |
dc.title | Diffractometer‐Control Software For Bragg‐Rod Measurements | en_US |
dc.type | Article | en_US |
dc.subject.hlbsecondlevel | Physics | en_US |
dc.subject.hlbtoplevel | Science | en_US |
dc.description.peerreviewed | Peer Reviewed | en_US |
dc.description.bitstreamurl | http://deepblue.lib.umich.edu/bitstream/2027.42/87660/2/1221_1.pdf | |
dc.identifier.doi | 10.1063/1.1758020 | en_US |
dc.identifier.source | SYNCHROTRON RADIATION INSTRUMENTATION: Eighth International Conference on Synchrotron Radiation Instrumentation | en_US |
dc.owningcollname | Physics, Department of |
Files in this item
Remediation of Harmful Language
The University of Michigan Library aims to describe library materials in a way that respects the people and communities who create, use, and are represented in our collections. Report harmful or offensive language in catalog records, finding aids, or elsewhere in our collections anonymously through our metadata feedback form. More information at Remediation of Harmful Language.
Accessibility
If you are unable to use this file in its current format, please select the Contact Us link and we can modify it to make it more accessible to you.