Ablation of Atrial Fibrillation Using an Irrigated‐Tip Catheter: Open or Closed?
dc.contributor.author | Latchamsetty, Rakesh | en_US |
dc.contributor.author | Oral, Hakan | en_US |
dc.date.accessioned | 2012-05-21T15:48:41Z | |
dc.date.available | 2013-07-01T14:33:05Z | en_US |
dc.date.issued | 2012-05 | en_US |
dc.identifier.citation | Latchamsetty, Rakesh ; Oral, Hakan (2012). "Ablation of Atrial Fibrillation Using an Irrigatedâ Tip Catheter: Open or Closed?." Pacing and Clinical Electrophysiology 35(5). <http://hdl.handle.net/2027.42/91175> | en_US |
dc.identifier.issn | 0147-8389 | en_US |
dc.identifier.issn | 1540-8159 | en_US |
dc.identifier.uri | https://hdl.handle.net/2027.42/91175 | |
dc.publisher | Blackwell Publishing Inc | en_US |
dc.publisher | Wiley Periodicals, Inc. | en_US |
dc.title | Ablation of Atrial Fibrillation Using an Irrigated‐Tip Catheter: Open or Closed? | en_US |
dc.type | Article | en_US |
dc.rights.robots | IndexNoFollow | en_US |
dc.subject.hlbsecondlevel | Physiology | en_US |
dc.subject.hlbtoplevel | Health Sciences | en_US |
dc.description.peerreviewed | Peer Reviewed | en_US |
dc.contributor.affiliationum | From the Division of Cardiovascular Medicine, University of Michigan, Ann Arbor, Michigan | en_US |
dc.identifier.pmid | 22360611 | en_US |
dc.description.bitstreamurl | http://deepblue.lib.umich.edu/bitstream/2027.42/91175/1/j.1540-8159.2012.03333.x.pdf | |
dc.identifier.doi | 10.1111/j.1540-8159.2012.03333.x | en_US |
dc.identifier.source | Pacing and Clinical Electrophysiology | en_US |
dc.identifier.citedreference | Golden K, Mounsey JP, Chung E, Roomiani P, Morse MA, Patel A, Gehi A. Atrial fibrillation ablation using a closed irrigation radiofrequency ablation catheter. Pacing Clin Electrophysiol May 2012 (in press). | en_US |
dc.identifier.citedreference | Cappato R, Calkins H, Chen SA, Davies W, Iesaka Y, Kalman J, Kim YH, et al. Updated worldwide survey on the methods, efficacy, and safety of catheter ablation for human atrial fibrillation. Circ Arrhythm Electrophysiol 2010; 3: 32 – 38. | en_US |
dc.identifier.citedreference | Nakagawa H, Yamanashi WS, Pitha JV, Arruda M, Wang X, Ohtomo K, Beckman KJ, et al. Comparison of in vivo tissue temperature profile and lesion geometry for radiofrequency ablation with a saline‐irrigated electrode versus temperature control in a canine thigh muscle preparation. Circulation 1995; 91: 2264 – 2273. | en_US |
dc.identifier.citedreference | Demazumder D, Mirotznik MS, Schwartzman D. Biophysics of radiofrequency ablation using an irrigated electrode. J Interv Card Electrophysiol 2001; 5: 377 – 389. | en_US |
dc.identifier.citedreference | Thomas SP, Aggarwal G, Boyd AC, Jin Y, Ross DL. A comparison of open irrigated and non‐irrigated tip catheter ablation for pulmonary vein isolation. Europace 2004; 6: 330 – 335. | en_US |
dc.identifier.citedreference | Chang SL, Tai CT, Lin YJ, Lo LW, Tuan TC, Udyavar AR, Hu YF, et al. Comparison of cooled‐tip versus 4‐mm‐tip catheter in the efficacy of acute ablative tissue injury during circumferential pulmonary vein isolation. J Cardiovasc Electrophysiol 2009; 20: 1113 – 1118. | en_US |
dc.identifier.citedreference | Dixit S, Gerstenfeld EP, Callans DJ, Cooper JM, Lin D, Russo AM, Verdino RJ, et al. Comparison of cool tip versus 8‐mm tip catheter in achieving electrical isolation of pulmonary veins for long‐term control of atrial fibrillation: A prospective randomized pilot study. J Cardiovasc Electrophysiol 2006; 17: 1074 – 1079. | en_US |
dc.identifier.citedreference | Everett TH, Lee KW, Wilson EE, Guerra JM, Varosy PD, Olgin JE. Safety profiles and lesion size of different radiofrequency ablation technologies: A comparison of large tip, open and closed irrigation catheters. J Cardiovasc Electrophysiol 2009; 20: 325 – 335. | en_US |
dc.identifier.citedreference | Ilg KJ, Kühne M, Crawford T, Chugh A, Jongnarangsin K, Good E, Pelosi F, et al. Randomized comparison of cavotricuspid isthmus ablation for atrial flutter using an open irrigation‐tip versus a large‐tip radiofrequency ablation catheter. J Cardiovasc Electrophysiol 2011; 22: 1007 – 1012. | en_US |
dc.identifier.citedreference | Yokoyama K, Nakagawa H, Wittkampf FH, Pitha JV, Lazzara R, Jackman WM. Comparison of electrode cooling between internal and open irrigation in radiofrequency ablation lesion depth and incidence of thrombus and steam pop. Circulation 2006; 113: 11 – 19. | en_US |
dc.identifier.citedreference | Thiagalingam A, D’Avila A, McPherson C, Malchano Z, Ruskin J, Reddy VY. Impedance and temperature monitoring improve the safety of closed‐loop irrigated‐tip radiofrequency ablation. J Cardiovasc Electrophysiol 2007; 18: 318 – 325. | en_US |
dc.identifier.citedreference | Cooper JM, Sapp JL, Tedrow U, Pellegrini CP, Robinson D, Epstein LM, Stevenson WG. Ablation with an internally irrigated radiofrequency catheter: Learning how to avoid steam pops. Heart Rhythm 2004; 1: 329 – 333. | en_US |
dc.identifier.citedreference | Nölker G, Gutleben KJ, Ritscher G, Rittger H, Asbach S, Heintze J, Muntean B, et al. Left atrial lesion formation and volume overload by open irrigation ablation technology during pulmonary vein antrum isolation: Acute effects on cardiac hemodynamics. J Interv Card Electrophysiol 2011; 31: 125 – 130. | en_US |
dc.owningcollname | Interdisciplinary and Peer-Reviewed |
Files in this item
Remediation of Harmful Language
The University of Michigan Library aims to describe library materials in a way that respects the people and communities who create, use, and are represented in our collections. Report harmful or offensive language in catalog records, finding aids, or elsewhere in our collections anonymously through our metadata feedback form. More information at Remediation of Harmful Language.
Accessibility
If you are unable to use this file in its current format, please select the Contact Us link and we can modify it to make it more accessible to you.