Show simple item record

Ablation of Atrial Fibrillation Using an Irrigated‐Tip Catheter: Open or Closed?

dc.contributor.authorLatchamsetty, Rakeshen_US
dc.contributor.authorOral, Hakanen_US
dc.date.accessioned2012-05-21T15:48:41Z
dc.date.available2013-07-01T14:33:05Zen_US
dc.date.issued2012-05en_US
dc.identifier.citationLatchamsetty, Rakesh ; Oral, Hakan (2012). "Ablation of Atrial Fibrillation Using an Irrigatedâ Tip Catheter: Open or Closed?." Pacing and Clinical Electrophysiology 35(5). <http://hdl.handle.net/2027.42/91175>en_US
dc.identifier.issn0147-8389en_US
dc.identifier.issn1540-8159en_US
dc.identifier.urihttps://hdl.handle.net/2027.42/91175
dc.publisherBlackwell Publishing Incen_US
dc.publisherWiley Periodicals, Inc.en_US
dc.titleAblation of Atrial Fibrillation Using an Irrigated‐Tip Catheter: Open or Closed?en_US
dc.typeArticleen_US
dc.rights.robotsIndexNoFollowen_US
dc.subject.hlbsecondlevelPhysiologyen_US
dc.subject.hlbtoplevelHealth Sciencesen_US
dc.description.peerreviewedPeer Revieweden_US
dc.contributor.affiliationumFrom the Division of Cardiovascular Medicine, University of Michigan, Ann Arbor, Michiganen_US
dc.identifier.pmid22360611en_US
dc.description.bitstreamurlhttp://deepblue.lib.umich.edu/bitstream/2027.42/91175/1/j.1540-8159.2012.03333.x.pdf
dc.identifier.doi10.1111/j.1540-8159.2012.03333.xen_US
dc.identifier.sourcePacing and Clinical Electrophysiologyen_US
dc.identifier.citedreferenceGolden K, Mounsey JP, Chung E, Roomiani P, Morse MA, Patel A, Gehi A. Atrial fibrillation ablation using a closed irrigation radiofrequency ablation catheter. Pacing Clin Electrophysiol May 2012 (in press).en_US
dc.identifier.citedreferenceCappato R, Calkins H, Chen SA, Davies W, Iesaka Y, Kalman J, Kim YH, et al. Updated worldwide survey on the methods, efficacy, and safety of catheter ablation for human atrial fibrillation. Circ Arrhythm Electrophysiol 2010; 3: 32 – 38.en_US
dc.identifier.citedreferenceNakagawa H, Yamanashi WS, Pitha JV, Arruda M, Wang X, Ohtomo K, Beckman KJ, et al. Comparison of in vivo tissue temperature profile and lesion geometry for radiofrequency ablation with a saline‐irrigated electrode versus temperature control in a canine thigh muscle preparation. Circulation 1995; 91: 2264 – 2273.en_US
dc.identifier.citedreferenceDemazumder D, Mirotznik MS, Schwartzman D. Biophysics of radiofrequency ablation using an irrigated electrode. J Interv Card Electrophysiol 2001; 5: 377 – 389.en_US
dc.identifier.citedreferenceThomas SP, Aggarwal G, Boyd AC, Jin Y, Ross DL. A comparison of open irrigated and non‐irrigated tip catheter ablation for pulmonary vein isolation. Europace 2004; 6: 330 – 335.en_US
dc.identifier.citedreferenceChang SL, Tai CT, Lin YJ, Lo LW, Tuan TC, Udyavar AR, Hu YF, et al. Comparison of cooled‐tip versus 4‐mm‐tip catheter in the efficacy of acute ablative tissue injury during circumferential pulmonary vein isolation. J Cardiovasc Electrophysiol 2009; 20: 1113 – 1118.en_US
dc.identifier.citedreferenceDixit S, Gerstenfeld EP, Callans DJ, Cooper JM, Lin D, Russo AM, Verdino RJ, et al. Comparison of cool tip versus 8‐mm tip catheter in achieving electrical isolation of pulmonary veins for long‐term control of atrial fibrillation: A prospective randomized pilot study. J Cardiovasc Electrophysiol 2006; 17: 1074 – 1079.en_US
dc.identifier.citedreferenceEverett TH, Lee KW, Wilson EE, Guerra JM, Varosy PD, Olgin JE. Safety profiles and lesion size of different radiofrequency ablation technologies: A comparison of large tip, open and closed irrigation catheters. J Cardiovasc Electrophysiol 2009; 20: 325 – 335.en_US
dc.identifier.citedreferenceIlg KJ, Kühne M, Crawford T, Chugh A, Jongnarangsin K, Good E, Pelosi F, et al. Randomized comparison of cavotricuspid isthmus ablation for atrial flutter using an open irrigation‐tip versus a large‐tip radiofrequency ablation catheter. J Cardiovasc Electrophysiol 2011; 22: 1007 – 1012.en_US
dc.identifier.citedreferenceYokoyama K, Nakagawa H, Wittkampf FH, Pitha JV, Lazzara R, Jackman WM. Comparison of electrode cooling between internal and open irrigation in radiofrequency ablation lesion depth and incidence of thrombus and steam pop. Circulation 2006; 113: 11 – 19.en_US
dc.identifier.citedreferenceThiagalingam A, D’Avila A, McPherson C, Malchano Z, Ruskin J, Reddy VY. Impedance and temperature monitoring improve the safety of closed‐loop irrigated‐tip radiofrequency ablation. J Cardiovasc Electrophysiol 2007; 18: 318 – 325.en_US
dc.identifier.citedreferenceCooper JM, Sapp JL, Tedrow U, Pellegrini CP, Robinson D, Epstein LM, Stevenson WG. Ablation with an internally irrigated radiofrequency catheter: Learning how to avoid steam pops. Heart Rhythm 2004; 1: 329 – 333.en_US
dc.identifier.citedreferenceNölker G, Gutleben KJ, Ritscher G, Rittger H, Asbach S, Heintze J, Muntean B, et al. Left atrial lesion formation and volume overload by open irrigation ablation technology during pulmonary vein antrum isolation: Acute effects on cardiac hemodynamics. J Interv Card Electrophysiol 2011; 31: 125 – 130.en_US
dc.owningcollnameInterdisciplinary and Peer-Reviewed


Files in this item

Show simple item record

Remediation of Harmful Language

The University of Michigan Library aims to describe library materials in a way that respects the people and communities who create, use, and are represented in our collections. Report harmful or offensive language in catalog records, finding aids, or elsewhere in our collections anonymously through our metadata feedback form. More information at Remediation of Harmful Language.

Accessibility

If you are unable to use this file in its current format, please select the Contact Us link and we can modify it to make it more accessible to you.