Work Description

Title: Real-time, volumetric imaging of radiation dose delivery deep into the liver during cancer treatment Open Access Deposited

h
Attribute Value
Methodology
  • The data are acquired with a customized designed 2D matrix array with integrated preamp. The data acquistion was achived by Verasonics Vantage 256 with software version 4.4.0. Instrument and/or Software specifications: Verasonics Vantage 256 with software version 4.4.0
Description
  • Ionizing radiation acoustic imaging (iRAI) allows online monitoring of radiation’s interactions with tissues during radiation therapy, providing real-time, adaptive feedback for cancer treatments. Using the data set presented here, this study demonstrated iRAI can image the temporal dose accumulation of a radiaiton treatment plan. Clincial standard treatment plan with both rabbit and patient in vivo were first real-time volumetric visulized by iRAI. This data set is the rawdata for our paper published in Nature Biotechnology entitled "Real-time, volumetric imaging of radiation dose delivery deep into the liver during cancer treatment ".
Creator
Depositor
  • zhawei@umich.edu
Contact information
Discipline
Funding agency
  • National Institutes of Health (NIH)
Date coverage
  • 2021-01-01 to 2022-03-31
Resource type
Last modified
  • 11/20/2022
Published
  • 10/27/2022
DOI
  • https://doi.org/10.7302/g05r-5a43
License
To Cite this Work:
Wei Zhang. (2022). Real-time, volumetric imaging of radiation dose delivery deep into the liver during cancer treatment [Data set], University of Michigan - Deep Blue Data. https://doi.org/10.7302/g05r-5a43

Relationships

This work is not a member of any user collections.

Files (Count: 9; Size: 33.9 GB)

Date: 27 October, 2022

Dataset Title: Real-time, volumetric imaging of radiation dose delivery deep into the liver during cancer treatment

Dataset Creators: Wei Zhang, Ibrahim Oraiqat, Dale Litzenberg, Kai-Wei Chang, Scott Hadley, Noora Ba Sunbul, Martha M. Matuszak, Christopher J. Tichacek, Eduardo G. Moros, Paul L. Carson, Kyle C. Cuneo, Xueding Wang, Issam El Naqa

Dataset Contact: Wei Zhang zhawei@umich.edu

Funding: R37CA222215 (NCI), P30CA046592(NCI), & Michigan Institute for Clinical and Health Research under Grant No.UL1 TR 002240

Key Points:
- iRAI can image the temporal dose accumulation of a radiaiton treatment plan
- The radiation dose delivery of a clincial standard treatment plan with rabbit in vivo can be directly imaging by iRAI
- Real-time visualization of 3D radiation dose delivered to a patient with liver metastases was accomplished with a clinical linear accelerator via iRAI.

Research Overview:

Ionizing radiation acoustic imaging (iRAI) allows online monitoring of radiation’s interactions with tissues during radiation therapy, providing real-time, adaptive feedback for cancer treatments.
This study demonstrated iRAI can image the temporal dose accumulation of a radiaiton treatment plan. Clincial standard treatment plan with both rabbit and patient in vivo were first real-time volumetric visulized by iRAI.

Methodology:
The data are acquired with a customized designed 2D matrix array with integrated preamp. The data acquistion was achived by Verasonics Vantage 256 with software version 4.4.0.

Instrument and/or Software specifications: Verasonics Vantage 256 with software version 4.4.0

Files contained here:
The folders show divisions based on each experiment. Different folders contain different files as discribed below.

Data acquisition code.rar

-This contains the codes for data acquistion. This code can not be run independently. It needs to be run in Verasoncis Vantage 256 system with software version 4.4.0.

Data processing example code.rar

-This contains the codes for data processing. These codes divide by two parts. One is for data reshape including the channel switch and multiplexer selection. Another part is for imaging reconstuction. This folder also contain an example date for running the code. The data can be replaced by all the other iRAI data.

iRAI for C shape.rar

-This contains 5 measurments of iRAI for C shape radiation dose delivery plan.

iRAI for rabbit treatmetn plan.rar

-This contains 3 measurments of iRAI for rabbit treatment plan.

iRAI for patient treatmetn plan.rar

-This contains the measurement of iRAI for patient treatment plan.

Treatment plan for C Shape.rar

-This contains the dcm files for the C shape radiation dose delivery plan.

Treatment plan for rabbit.rar

-This contains the dcm files for the radiation treatment plan of rabbit.

Treatment plan for patient.rar

-This contains the dcm files for the radiation treatment plan of patient. (Only the treatment plan that imaged by iRAI was included.)

Related publication(s):
Zhang, W., et al. (2022). Real-time, volumetric imaging of radiation dose delivery deep into the liver during cancer treatment. Forthcoming.

Use and Access:
This data set is made available under a Attribution-NonCommercial 4.0 International (CC BY-NC 4.0).

To Cite Data:
Zhang, W., et al.(2022). Real-time, volumetric imaging of radiation dose delivery deep into the liver during cancer treatment [Data set]. University of Michigan - Deep Blue. https://doi.org/10.7302/g05r-5a43

Download All Files (To download individual files, select them in the “Files” panel above)

Total work file size of 33.9 GB is too large to download directly. Consider using Globus (see below).

Files are ready   Download Data from Globus
Best for data sets > 3 GB. Globus is the platform Deep Blue Data uses to make large data sets available.   More about Globus

Remediation of Harmful Language

The University of Michigan Library aims to describe library materials in a way that respects the people and communities who create, use, and are represented in our collections. Report harmful or offensive language in catalog records, finding aids, or elsewhere in our collections anonymously through our metadata feedback form. More information at Remediation of Harmful Language.