Work Description
Title: Real-time, volumetric imaging of radiation dose delivery deep into the liver during cancer treatment Open Access Deposited
Attribute | Value |
---|---|
Methodology |
|
Description |
|
Creator | |
Depositor |
|
Contact information | |
Discipline | |
Funding agency |
|
Date coverage |
|
Resource type | |
Last modified |
|
Published |
|
DOI |
|
License |
(2022). Real-time, volumetric imaging of radiation dose delivery deep into the liver during cancer treatment [Data set], University of Michigan - Deep Blue Data. https://doi.org/10.7302/g05r-5a43
Relationships
- This work is not a member of any user collections.
Files (Count: 9; Size: 33.9 GB)
Thumbnailthumbnail-column | Title | Original Upload | Last Modified | File Size | Access | Actions |
---|---|---|---|---|---|---|
Readme.txt | 2022-10-27 | 2022-10-27 | 3.52 KB | Open Access |
|
|
Data_acquisition_code.rar | 2022-10-27 | 2022-10-27 | 10.7 KB | Open Access |
|
|
Data_processing_example_code.rar | 2022-10-27 | 2022-10-27 | 1.72 GB | Open Access |
|
|
Teatment_plan_for_patient.rar | 2022-10-27 | 2022-10-27 | 54.6 MB | Open Access |
|
|
Treatment_plan_for_C_shape.rar | 2022-10-27 | 2022-10-27 | 7.76 MB | Open Access |
|
|
Treatment_Plan_for_rabbit.rar | 2022-10-27 | 2022-10-27 | 46.2 MB | Open Access |
|
|
iRAI_for_patient_treatment_plan.rar | 2022-10-27 | 2022-10-27 | 1.08 GB | Open Access |
|
|
iRAI for C shape.rar | 2022-10-27 | 2022-10-27 | 8.31 GB | Open Access |
|
|
iRAI for rabbit treatment plan.rar | 2022-10-27 | 2022-10-27 | 22.6 GB | Open Access |
|
Date: 27 October, 2022
Dataset Title: Real-time, volumetric imaging of radiation dose delivery deep into the liver during cancer treatment
Dataset Creators: Wei Zhang, Ibrahim Oraiqat, Dale Litzenberg, Kai-Wei Chang, Scott Hadley, Noora Ba Sunbul, Martha M. Matuszak, Christopher J. Tichacek, Eduardo G. Moros, Paul L. Carson, Kyle C. Cuneo, Xueding Wang, Issam El Naqa
Dataset Contact: Wei Zhang zhawei@umich.edu
Funding: R37CA222215 (NCI), P30CA046592(NCI), & Michigan Institute for Clinical and Health Research under Grant No.UL1 TR 002240
Key Points:
- iRAI can image the temporal dose accumulation of a radiaiton treatment plan
- The radiation dose delivery of a clincial standard treatment plan with rabbit in vivo can be directly imaging by iRAI
- Real-time visualization of 3D radiation dose delivered to a patient with liver metastases was accomplished with a clinical linear accelerator via iRAI.
Research Overview:
Ionizing radiation acoustic imaging (iRAI) allows online monitoring of radiation’s interactions with tissues during radiation therapy, providing real-time, adaptive feedback for cancer treatments.
This study demonstrated iRAI can image the temporal dose accumulation of a radiaiton treatment plan. Clincial standard treatment plan with both rabbit and patient in vivo were first real-time volumetric visulized by iRAI.
Methodology:
The data are acquired with a customized designed 2D matrix array with integrated preamp. The data acquistion was achived by Verasonics Vantage 256 with software version 4.4.0.
Instrument and/or Software specifications: Verasonics Vantage 256 with software version 4.4.0
Files contained here:
The folders show divisions based on each experiment. Different folders contain different files as discribed below.
Data acquisition code.rar
-This contains the codes for data acquistion. This code can not be run independently. It needs to be run in Verasoncis Vantage 256 system with software version 4.4.0.
Data processing example code.rar
-This contains the codes for data processing. These codes divide by two parts. One is for data reshape including the channel switch and multiplexer selection. Another part is for imaging reconstuction. This folder also contain an example date for running the code. The data can be replaced by all the other iRAI data.
iRAI for C shape.rar
-This contains 5 measurments of iRAI for C shape radiation dose delivery plan.
iRAI for rabbit treatmetn plan.rar
-This contains 3 measurments of iRAI for rabbit treatment plan.
iRAI for patient treatmetn plan.rar
-This contains the measurement of iRAI for patient treatment plan.
Treatment plan for C Shape.rar
-This contains the dcm files for the C shape radiation dose delivery plan.
Treatment plan for rabbit.rar
-This contains the dcm files for the radiation treatment plan of rabbit.
Treatment plan for patient.rar
-This contains the dcm files for the radiation treatment plan of patient. (Only the treatment plan that imaged by iRAI was included.)
Related publication(s):
Zhang, W., et al. (2022). Real-time, volumetric imaging of radiation dose delivery deep into the liver during cancer treatment. Forthcoming.
Use and Access:
This data set is made available under a Attribution-NonCommercial 4.0 International (CC BY-NC 4.0).
To Cite Data:
Zhang, W., et al.(2022). Real-time, volumetric imaging of radiation dose delivery deep into the liver during cancer treatment [Data set]. University of Michigan - Deep Blue. https://doi.org/10.7302/g05r-5a43