Show simple item record

Diagnostic value of fine needle aspirates processed by ThinPrep® for the assessment of axillary lymph node status in patients with invasive carcinoma of the breast

dc.contributor.authorJing, X.en_US
dc.contributor.authorWey, E.en_US
dc.contributor.authorMichael, C. W.en_US
dc.date.accessioned2013-12-04T18:57:57Z
dc.date.available2015-01-05T13:54:43Zen_US
dc.date.issued2013-12en_US
dc.identifier.citationJing, X.; Wey, E.; Michael, C. W. (2013). "Diagnostic value of fine needle aspirates processed by ThinPrep® for the assessment of axillary lymph node status in patients with invasive carcinoma of the breast." Cytopathology 24(6).en_US
dc.identifier.issn0956-5507en_US
dc.identifier.issn1365-2303en_US
dc.identifier.urihttps://hdl.handle.net/2027.42/101854
dc.publisherWiley Periodicals, Inc.en_US
dc.publisherBlackwell Publishing Ltden_US
dc.subject.otherLiquid‐Based Cytologyen_US
dc.subject.otherInvasive Breast Carcinomaen_US
dc.subject.otherNodal Metastasisen_US
dc.subject.otherFine Needle Aspirationen_US
dc.subject.otherThinPrepen_US
dc.titleDiagnostic value of fine needle aspirates processed by ThinPrep® for the assessment of axillary lymph node status in patients with invasive carcinoma of the breasten_US
dc.typeArticleen_US
dc.rights.robotsIndexNoFollowen_US
dc.subject.hlbsecondlevelOncology and Hematologyen_US
dc.subject.hlbtoplevelHealth Sciencesen_US
dc.description.peerreviewedPeer Revieweden_US
dc.contributor.affiliationumDepartment of Pathology, University of Michigan, Ann Arbor, MI, USAen_US
dc.contributor.affiliationotherDepartment of Pathology, Beaumont Hospital, Troy, MI, USAen_US
dc.contributor.affiliationotherDepartment of Pathology, Case Western University/University Hospitals Case Medical Center, Cleveland, OH, USAen_US
dc.description.bitstreamurlhttp://deepblue.lib.umich.edu/bitstream/2027.42/101854/1/cyt12022.pdf
dc.identifier.doi10.1111/cyt.12022en_US
dc.identifier.sourceCytopathologyen_US
dc.identifier.citedreferenceSahoo S, Sanders MA, Roland L, Pile N, Chagpar AB. A strategic approach to the evaluation of axillary lymph nodes in breast cancer patients: analysis of 168 patients at a single institution. Am J Surg 2007; 194: 524 – 6.en_US
dc.identifier.citedreferenceDeurloo EE, Tanis PJ, Gilhuijs KG et al. Reduction in the number of sentinel lymph node procedures by preoperative ultrasonography of the axilla in breast cancer. Eur J Cancer 2003; 39: 1068 – 73.en_US
dc.identifier.citedreferenceJain A, Haisfield‐Wolfe ME, Lange J et al. The role of ultrasound‐guided fine‐needle aspiration of axillary nodes in the staging of breast cancer. Ann Surg Oncol 2008; 15: 462 – 71.en_US
dc.identifier.citedreferenceKoelliker SL, Chung MA, Mainiero MB, Steinhoff MM, Cady B. Axillary lymph nodes: US‐guided fine‐needle aspiration for initial staging of breast cancer‐‐correlation with primary tumor size. Radiology 2008; 246: 81 – 9.en_US
dc.identifier.citedreferenceAlkuwari E, Auger M. Accuracy of fine‐needle aspiration cytology of axillary lymph nodes in breast cancer patients: a study of 115 cases with cytologic‐histologic correlation. Cancer 2008; 114: 89 – 93.en_US
dc.identifier.citedreferenceSwinson C, Ravichandran D, Nayagam M, Allen S. Ultrasound and fine needle aspiration cytology of the axilla in the pre‐operative identification of axillary nodal involvement in breast cancer. Eur J Surg Oncol 2009; 35: 1152 – 7.en_US
dc.identifier.citedreferencePark SH, Kim MJ, Park BW et al. Impact of preoperative ultrasonography and fine‐needle aspiration of axillary lymph nodes on surgical management of primary breast cancer. Ann Surg Oncol 2011; 18: 738 – 44.en_US
dc.identifier.citedreferenceSapino A, Cassoni P, Zanon E et al. Ultrasonographically‐guided fine‐needle aspiration of axillary lymph nodes: role in breast cancer management. Br J Cancer 2003; 88: 702 – 6.en_US
dc.identifier.citedreferenceCiatto S, Brancato B, Risso G et al. Accuracy of fine needle aspiration cytology (FNAC) of axillary lymph nodes as a triage test in breast cancer staging. Breast Cancer Res Treat 2007; 103: 85 – 91.en_US
dc.identifier.citedreferencekrishnamurthy S, Hynek I, Hunt KK, Yang WT. Utility of ultrasound‐guided fine needle aspiration of indeterminate and suspicious axillary lymph nodes in the management of patients with early breast cancer: a study of 278 patients. Cancer Cytopathol 2008; 114: 2.en_US
dc.identifier.citedreferenceMichael CW, Hunter B. Interpretation of fine‐needle aspirates processed by the ThinPrep technique: cytologic artifacts and diagnostic pitfalls. Diagn Cytopathol 2000; 23: 6 – 13.en_US
dc.identifier.citedreferenceGilissen F, Oostenbroek R, Storm R, Westenend P, Plaisier P. Prevention of futile sentinel node procedures in breast cancer: ultrasonography of the axilla and fine‐needle aspiration cytology are obligatory. Eur J Surg Oncol 2008; 34: 497 – 500.en_US
dc.identifier.citedreferenceAltomare V, Guerriero G, Carino R et al. Axillary lymph node echo‐guided fine‐needle aspiration cytology enables breast cancer patients to avoid a sentinel lymph node biopsy. Preliminary experience and a review of the literature. Surg Today 2007; 37: 735 – 9.en_US
dc.owningcollnameInterdisciplinary and Peer-Reviewed


Files in this item

Show simple item record

Remediation of Harmful Language

The University of Michigan Library aims to describe library materials in a way that respects the people and communities who create, use, and are represented in our collections. Report harmful or offensive language in catalog records, finding aids, or elsewhere in our collections anonymously through our metadata feedback form. More information at Remediation of Harmful Language.

Accessibility

If you are unable to use this file in its current format, please select the Contact Us link and we can modify it to make it more accessible to you.