Show simple item record

Origin of Low Detection Limit and High Selectivity of Roche Accu‐Chek Test Strips that Enables Measurement of Tear Glucose Levels

dc.contributor.authorCha, Kyoung Haen_US
dc.contributor.authorQin, Yuen_US
dc.contributor.authorMeyerhoff, Mark E.en_US
dc.date.accessioned2015-04-02T15:12:44Z
dc.date.available2016-05-10T20:26:28Zen
dc.date.issued2015-03en_US
dc.identifier.citationCha, Kyoung Ha; Qin, Yu; Meyerhoff, Mark E. (2015). "Origin of Low Detection Limit and High Selectivity of Roche Accu‐Chek Test Strips that Enables Measurement of Tear Glucose Levels." Electroanalysis 27(3): 670-676.en_US
dc.identifier.issn1040-0397en_US
dc.identifier.issn1521-4109en_US
dc.identifier.urihttps://hdl.handle.net/2027.42/110886
dc.description.abstractTear glucose measurements have been suggested as a potential alternative to blood glucose monitoring for diabetic patients. While previous work has reported a correlation between blood and tear glucose levels in humans, this link has not been thoroughly established and additional clinical studies are needed. We recently reported that Roche’s electrochemical Accu‐Chek blood glucose test strips exhibit far superior analytical performance over other commercial brands, with the low detection limit and high selectivity required for quantitating tear glucose levels. Herein, we evaluate the origin of the high sensitivity and selectivity of the Roche test strips and show that the use of pyrroloquinoline quinone (PQQ)‐dependent glucose dehydrogenase (GDH) as an active enzyme reagent in combination with a nitrosoaniline derivative as an electron transfer mediator are primarily responsible for the low limit of quantification (LOQ) (ca. 9 µM) and enhanced selectivity achieved with these strips.en_US
dc.publisherWILEY‐VCH Verlagen_US
dc.subject.otherTear glucoseen_US
dc.subject.otherNitrosoaniline derivativeen_US
dc.subject.otherPQQ‐dependent glucose dehydrogenaseen_US
dc.subject.otherBiamperometryen_US
dc.subject.otherRoche Accu‐Chek glucometer stripsen_US
dc.titleOrigin of Low Detection Limit and High Selectivity of Roche Accu‐Chek Test Strips that Enables Measurement of Tear Glucose Levelsen_US
dc.typeArticleen_US
dc.rights.robotsIndexNoFollowen_US
dc.subject.hlbsecondlevelMaterials Science and Engineeringen_US
dc.subject.hlbsecondlevelBiological Chemistryen_US
dc.subject.hlbsecondlevelChemical Engineeringen_US
dc.subject.hlbsecondlevelChemistryen_US
dc.subject.hlbtoplevelHealth Sciencesen_US
dc.subject.hlbtoplevelScienceen_US
dc.subject.hlbtoplevelEngineeringen_US
dc.description.peerreviewedPeer Revieweden_US
dc.contributor.affiliationumDepartment of Chemistry, University of Michigan, Ann Arbor, MI, 48109‐1055, USAen_US
dc.description.bitstreamurlhttp://deepblue.lib.umich.edu/bitstream/2027.42/110886/1/670_ftp.pdf
dc.identifier.doi10.1002/elan.201400576en_US
dc.identifier.sourceElectroanalysisen_US
dc.identifier.citedreferenceJ. K. Lane, D. M. Krumholz, R. A. Sack, C. Morris, Curr. Eye Res. 2006, 31, 895 – 901.en_US
dc.identifier.citedreferenceG. Danaei, M. M. Finucane, Y. Lu, G. M. Singh, M. J. Cowan, C. J. Paciorek, J. K. Lin, F. Farzadfar, Y. H. Khang, G. A. Stevens, M. Rao, M. K. Ali, L. M. Riley, C. A. Robinson, M. Ezzati, Lancet 2011, 378, 31 – 40.en_US
dc.identifier.citedreferenceGlobal Status Report on Noncommunicable Diseases 2010, World Health Organization, Geneva, 2011.en_US
dc.identifier.citedreferenceP. Zimmet, K. G. M. M. Alberti, J. Shaw, Nature 2001, 414, 782 – 787.en_US
dc.identifier.citedreferenceM. Brownlee, Nature 2001, 414, 813 – 820.en_US
dc.identifier.citedreferenceJ. Hönes, P. Müller, N. Surridge, Diabetes Technol. Ther. 2008, 10, S 10 –S 26.en_US
dc.identifier.citedreferenceE. Minder, D. Albrecht, J. Schäfer, H. Zulewski, Diabetes Res. Clin. Pract. 2013, 101, 57 – 61.en_US
dc.identifier.citedreferenceJ. T. Baca, C. R. Taormina, E. Feingold, D. N. Finegold, J. J. Grabowski, S. A. Asher, Clin. Chem. 2007, 53, 1370 – 1372en_US
dc.identifier.citedreferenceK. H. Cha, G. C. Jensen, A. S. Balijepalli, B. E. Cohan, M. E. Meyerhoff, Anal. Chem. 2014, 86, 1902 – 1908.en_US
dc.identifier.citedreferenceD. W. Burke, M. Marquant, Test Strip with Slot Vent Opening. U. S. Patent 8, 211, 379, July 3, 2012.en_US
dc.identifier.citedreferenceX. Yuan, M. Iijima, M. Oishi, Y. Nagasaki, Langmuir, 2008, 24, 6903 – 6909.en_US
dc.identifier.citedreferenceL. D. Smith, N. Budgen, S. J. Bungard, M. J. Danson, D. W. Hough, Biochem. J. 1989, 261, 973 – 977.en_US
dc.identifier.citedreferenceD. Fapyane, S. J. Lee, S. H. Kang, D. H. Lim, K. K. Cho, T. H. Nam, J. P. Ahn, J. H. Ahn, S. W. Kim, I. S. Chang, Phys. Chem. Chem. Phys. 2013, 15, 9508 – 9512.en_US
dc.identifier.citedreferenceR. Wilson, A. P. F. Turner, Biosens. Bioelectron. 1992, 7, 165 – 185.en_US
dc.identifier.citedreferenceZ. P. Tang, R. F. Louie, J. H. Lee, D. M. Lee, E. E. Miller, G. Kost, J. Crit. Care Med. 2001, 29, 1062 – 1070.en_US
dc.identifier.citedreferenceH. Yamaoka, K. Sode, Open Biotechnol. J. 2007, 1, 26 – 30.en_US
dc.identifier.citedreferenceC. K. M. Choy, P. Cho, W. Y. Chung, I. F. F. Benzie, Optom. Vis. Sci. 2003, 80, 632 – 636.en_US
dc.identifier.citedreferenceC. K. M. Choy, I. F. F. Benzie, P. Cho, Invest. Ophthalmol. Vis. Sci. 2000, 41, 3293 – 3298.en_US
dc.identifier.citedreferenceC. R. Taormina, J. T. Baca, S. A. Asher, J. J. Grabowski, J. Am. Soc. Mass. Spec. 2007, 18, 332 – 336.en_US
dc.owningcollnameInterdisciplinary and Peer-Reviewed


Files in this item

Show simple item record

Remediation of Harmful Language

The University of Michigan Library aims to describe library materials in a way that respects the people and communities who create, use, and are represented in our collections. Report harmful or offensive language in catalog records, finding aids, or elsewhere in our collections anonymously through our metadata feedback form. More information at Remediation of Harmful Language.

Accessibility

If you are unable to use this file in its current format, please select the Contact Us link and we can modify it to make it more accessible to you.