Show simple item record

Learning to walk with an adaptive gain proportional myoelectric controller for a robotic ankle exoskeleton

dc.contributor.authorKoller, Jeffrey R
dc.contributor.authorJacobs, Daniel A
dc.contributor.authorFerris, Daniel P
dc.contributor.authorRemy, C. D
dc.date.accessioned2015-11-04T19:02:32Z
dc.date.available2015-11-04T19:02:32Z
dc.date.issued2015-11-04
dc.identifier.citationJournal of NeuroEngineering and Rehabilitation. 2015 Nov 04;12(1):97
dc.identifier.urihttps://hdl.handle.net/2027.42/115879en_US
dc.description.abstractAbstract Background Robotic ankle exoskeletons can provide assistance to users and reduce metabolic power during walking. Our research group has investigated the use of proportional myoelectric control for controlling robotic ankle exoskeletons. Previously, these controllers have relied on a constant gain to map user’s muscle activity to actuation control signals. A constant gain may act as a constraint on the user, so we designed a controller that dynamically adapts the gain to the user’s myoelectric amplitude. We hypothesized that an adaptive gain proportional myoelectric controller would reduce metabolic energy expenditure compared to walking with the ankle exoskeleton unpowered because users could choose their preferred control gain. Methods We tested eight healthy subjects walking with the adaptive gain proportional myoelectric controller with bilateral ankle exoskeletons. The adaptive gain was updated each stride such that on average the user’s peak muscle activity was mapped to maximal power output of the exoskeleton. All subjects participated in three identical training sessions where they walked on a treadmill for 50 minutes (30 minutes of which the exoskeleton was powered) at 1.2 ms-1. We calculated and analyzed metabolic energy consumption, muscle recruitment, inverse kinematics, inverse dynamics, and exoskeleton mechanics. Results Using our controller, subjects achieved a metabolic reduction similar to that seen in previous work in about a third of the training time. The resulting controller gain was lower than that seen in previous work (β=1.50±0.14 versus a constant β=2). The adapted gain allowed users more total ankle joint power than that of unassisted walking, increasing ankle power in exchange for a decrease in hip power. Conclusions Our findings indicate that humans prefer to walk with greater ankle mechanical power output than their unassisted gait when provided with an ankle exoskeleton using an adaptive controller. This suggests that robotic assistance from an exoskeleton can allow humans to adopt gait patterns different from their normal choices for locomotion. In our specific experiment, subjects increased ankle power and decreased hip power to walk with a reduction in metabolic cost. Future exoskeleton devices that rely on proportional myolectric control are likely to demonstrate improved performance by including an adaptive gain.
dc.titleLearning to walk with an adaptive gain proportional myoelectric controller for a robotic ankle exoskeleton
dc.typeArticleen_US
dc.description.bitstreamurlhttp://deepblue.lib.umich.edu/bitstream/2027.42/115879/1/12984_2015_Article_86.pdf
dc.identifier.doi10.1186/s12984-015-0086-5en_US
dc.language.rfc3066en
dc.rights.holderKoller et al.
dc.date.updated2015-11-04T19:02:32Z
dc.owningcollnameInterdisciplinary and Peer-Reviewed


Files in this item

Show simple item record

Remediation of Harmful Language

The University of Michigan Library aims to describe library materials in a way that respects the people and communities who create, use, and are represented in our collections. Report harmful or offensive language in catalog records, finding aids, or elsewhere in our collections anonymously through our metadata feedback form. More information at Remediation of Harmful Language.

Accessibility

If you are unable to use this file in its current format, please select the Contact Us link and we can modify it to make it more accessible to you.