Show simple item record

On-line monitoring and PET imaging of the positron-emitting activity created in tissue by proton radiotherapy beams.

dc.contributor.authorLitzenberg, Dale William
dc.contributor.advisorJr., Frederick Becchetti,
dc.date.accessioned2016-08-30T17:28:58Z
dc.date.available2016-08-30T17:28:58Z
dc.date.issued1997
dc.identifier.urihttp://gateway.proquest.com/openurl?url_ver=Z39.88-2004&rft_val_fmt=info:ofi/fmt:kev:mtx:dissertation&res_dat=xri:pqm&rft_dat=xri:pqdiss:9732128
dc.identifier.urihttps://hdl.handle.net/2027.42/130527
dc.description.abstractProton radiotherapy is a powerful tool in the local control of cancer. The advantages of proton radiotherapy over gamma-ray therapy arise from the phenomenon known as the Bragg peak. This phenomenon enables large doses to be delivered to well-defined volumes while sparing surrounding healthy tissue. To fully realize the potential of this technique the location of the high dose volume must be controlled very accurately. An imaging system was designed and tested to monitor the positron-emitting activity created by the beam as a means of verifying the beams range and determining tissue composition. Design studies of the detection system are presented, the data acquisition system used is described and the results of on-line experiments with proton beams are presented. The depth-distribution of positron-emitting activity created by proton radiotherapy beams was imaged on-line using this system. Decay data was acquired and imaged between beam pulses and after the irradiation. Over 80% of the initial positron-emitting activity is from $\sp{15}$O which has a half-life of 122 seconds. The residual range of the treatment beam below the energy threshold for producing $\sp{15}$O is 0.3 cm. Consequently, the end of the activity distribution and the location of the Bragg peak are well correlated in homogenous tissue. The results show that the range of a 150 MeV proton radiotherapy beam may be verified after a single beam pulse to within a detectors width of the imaging system. The integrated total dose delivered to the patient may also be monitored by observing the increase in the number of coincidence events detected between successive beam pulses. It is also shown that in some situations the width of the plateau region of a Spread-Out Bragg Peak (SOBP) may be inferred from the fall of activity at the distal end of the distribution. Radioisotopic imaging may be performed along the beam path if decay data is collected after the treatment is completed. It is shown that using this technique, variations in elemental composition in inhomogenous treatment volumes may be identified and used to locate anatomical landmarks. Radioisotopic imaging also reveals that $\sp{14}$O is created well beyond the Bragg peak, apparently by secondary neutrons.
dc.format.extent199 p.
dc.languageEnglish
dc.language.isoEN
dc.subjectActivity
dc.subjectBeams
dc.subjectCreated
dc.subjectEmitting
dc.subjectImaging
dc.subjectLine
dc.subjectMonitoring
dc.subjectOn
dc.subjectPet
dc.subjectPositron
dc.subjectProton
dc.subjectRadiotherapy
dc.subjectTissue
dc.titleOn-line monitoring and PET imaging of the positron-emitting activity created in tissue by proton radiotherapy beams.
dc.typeThesis
dc.description.thesisdegreenamePhDen_US
dc.description.thesisdegreedisciplineApplied Sciences
dc.description.thesisdegreedisciplineBiomedical engineering
dc.description.thesisdegreedisciplineHealth and Environmental Sciences
dc.description.thesisdegreedisciplineMedical imaging
dc.description.thesisdegreedisciplineNuclear physics
dc.description.thesisdegreedisciplinePure Sciences
dc.description.thesisdegreegrantorUniversity of Michigan, Horace H. Rackham School of Graduate Studies
dc.description.bitstreamurlhttp://deepblue.lib.umich.edu/bitstream/2027.42/130527/2/9732128.pdf
dc.owningcollnameDissertations and Theses (Ph.D. and Master's)


Files in this item

Show simple item record

Remediation of Harmful Language

The University of Michigan Library aims to describe library materials in a way that respects the people and communities who create, use, and are represented in our collections. Report harmful or offensive language in catalog records, finding aids, or elsewhere in our collections anonymously through our metadata feedback form. More information at Remediation of Harmful Language.

Accessibility

If you are unable to use this file in its current format, please select the Contact Us link and we can modify it to make it more accessible to you.