Show simple item record

Signal, noise, and detective quantum efficiency of amorphous-silicon:hydrogen flat-panel imagers.

dc.contributor.authorSiewerdsen, Jeffrey Harold
dc.contributor.advisorAntonuk, Larry E.
dc.contributor.advisorLongo, Michael J.
dc.date.accessioned2016-08-30T17:44:01Z
dc.date.available2016-08-30T17:44:01Z
dc.date.issued1998
dc.identifier.urihttp://gateway.proquest.com/openurl?url_ver=Z39.88-2004&rft_val_fmt=info:ofi/fmt:kev:mtx:dissertation&res_dat=xri:pqm&rft_dat=xri:pqdiss:9840647
dc.identifier.urihttps://hdl.handle.net/2027.42/131326
dc.description.abstractFlat-panel imagers based upon the technology of thin-film amorphous silicon transistors and photodiodes are under investigation for a wide variety of medical imaging applications. This thesis presents quantitative empirical and theoretical investigations of the imaging performance of such imaging systems. Performance was evaluated in terms of imager signal size, spatial resolution, noise characteristics, and signal-to-noise ratio for a wide variety of imaging system configurations and exposure conditions relevant to medical imaging. A theoretical model based upon cascaded systems analysis allowed prediction of imager signal, noise, and detective quantum efficiency (DQE), and theoretical results were found to agree well with empirical measurements. The empirical and theoretical analyses yielded quantification of the performance of existing imager designs, allowed investigation of the potential performance of future flat-panel imaging systems, and provided a methodology for identifying optimal imager configurations for various applications and imaging tasks. There is every indication that flat-panel imagers could provide performance superior to that of existing clinical imaging technologies. For example, in general x-ray radiography, mammography, and radiotherapy portal imaging, such systems could provide DQE exceeding 60%, 80%, and 1.5%, respectively, approximately twice that of film-based systems. However, for applications involving very low exposures per image, e.g., real-time fluoroscopy, such systems may suffer from reduced signal-to-noise ratio. The analyses developed in this thesis provide an effective means of identifying strategies for improved imager performance and will facilitate the realization of optimized flat-panel imagers that physically achieve their maximum theoretical performance.
dc.format.extent254 p.
dc.languageEnglish
dc.language.isoEN
dc.subjectAmorphous Silicon
dc.subjectDetective
dc.subjectEffici
dc.subjectFlat Panel Imagers
dc.subjectHydrogen
dc.subjectNoise
dc.subjectQuantum Efficiency
dc.subjectSi
dc.subjectSignal
dc.titleSignal, noise, and detective quantum efficiency of amorphous-silicon:hydrogen flat-panel imagers.
dc.typeThesis
dc.description.thesisdegreenamePhDen_US
dc.description.thesisdegreedisciplineApplied Sciences
dc.description.thesisdegreedisciplineBiomedical engineering
dc.description.thesisdegreedisciplineCondensed matter physics
dc.description.thesisdegreedisciplineElectrical engineering
dc.description.thesisdegreedisciplinePure Sciences
dc.description.thesisdegreegrantorUniversity of Michigan, Horace H. Rackham School of Graduate Studies
dc.description.bitstreamurlhttp://deepblue.lib.umich.edu/bitstream/2027.42/131326/2/9840647.pdf
dc.owningcollnameDissertations and Theses (Ph.D. and Master's)


Files in this item

Show simple item record

Remediation of Harmful Language

The University of Michigan Library aims to describe its collections in a way that respects the people and communities who create, use, and are represented in them. We encourage you to Contact Us anonymously if you encounter harmful or problematic language in catalog records or finding aids. More information about our policies and practices is available at Remediation of Harmful Language.

Accessibility

If you are unable to use this file in its current format, please select the Contact Us link and we can modify it to make it more accessible to you.