Use and uncertainties of mutual information for computed tomography/magnetic resonance (CT/MR) registration post permanent implant of the prostate
dc.contributor.author | Roberson, Peter L. | |
dc.contributor.author | McLaughlin, P. William | |
dc.contributor.author | Narayana, Vrinda | |
dc.contributor.author | Troyer, Sara | |
dc.contributor.author | Hixson, George V. | |
dc.contributor.author | Kessler, Marc L. | |
dc.date.accessioned | 2017-01-06T20:46:34Z | |
dc.date.available | 2017-01-06T20:46:34Z | |
dc.date.issued | 2005-02 | |
dc.identifier.citation | Roberson, Peter L.; McLaughlin, P. William; Narayana, Vrinda; Troyer, Sara; Hixson, George V.; Kessler, Marc L. (2005). "Use and uncertainties of mutual information for computed tomography/magnetic resonance (CT/MR) registration post permanent implant of the prostate." Medical Physics 32(2): 473-482. | |
dc.identifier.issn | 0094-2405 | |
dc.identifier.issn | 2473-4209 | |
dc.identifier.uri | https://hdl.handle.net/2027.42/134844 | |
dc.publisher | American Association of Physicists in Medicine | |
dc.publisher | Wiley Periodicals, Inc. | |
dc.subject.other | biological organs | |
dc.subject.other | Computed radiography | |
dc.subject.other | Magnetic resonance imaging | |
dc.subject.other | Therapeutic applications, including brachytherapy | |
dc.subject.other | Image analysis | |
dc.subject.other | General statistical methods | |
dc.subject.other | computerised tomography | |
dc.subject.other | biomedical MRI | |
dc.subject.other | medical image processing | |
dc.subject.other | image reconstruction | |
dc.subject.other | image registration | |
dc.subject.other | prosthetics | |
dc.subject.other | dosimetry | |
dc.subject.other | brachytherapy | |
dc.subject.other | radioactive sources | |
dc.subject.other | least squares approximations | |
dc.subject.other | mutual information | |
dc.subject.other | prostate brachytherapy | |
dc.subject.other | registration, MR, CT | |
dc.subject.other | Computed tomography | |
dc.subject.other | Medical imaging | |
dc.subject.other | Data sets | |
dc.subject.other | Magnetic resonance | |
dc.subject.other | Medical magnetic resonance imaging | |
dc.subject.other | Anatomy | |
dc.subject.other | Tissues | |
dc.subject.other | Dosimetry | |
dc.subject.other | Brachytherapy | |
dc.subject.other | Probability density functions | |
dc.title | Use and uncertainties of mutual information for computed tomography/magnetic resonance (CT/MR) registration post permanent implant of the prostate | |
dc.type | Article | en_US |
dc.rights.robots | IndexNoFollow | |
dc.subject.hlbsecondlevel | Medicine (General) | |
dc.subject.hlbtoplevel | Health Sciences | |
dc.description.peerreviewed | Peer Reviewed | |
dc.contributor.affiliationum | University of Michigan, Department of Radiation Oncology, Ann Arbor, Michigan 48109 and Providence Cancer Center, Department of Radiation Oncology, Southfield, Michigan 48075 | |
dc.contributor.affiliationum | University of Michigan, Department of Radiation Oncology, Ann Arbor, Michigan 48109 | |
dc.contributor.affiliationum | University of Michigan, Department of Radiation Oncology, Ann Arbor, Michigan 48109 | |
dc.contributor.affiliationum | University of Michigan, Department of Radiation Oncology, Ann Arbor, Michigan 48109 | |
dc.contributor.affiliationother | Providence Cancer Center, Department of Radiation Oncology, Southfield, Michigan 48075 | |
dc.description.bitstreamurl | http://deepblue.lib.umich.edu/bitstream/2027.42/134844/1/mp1920.pdf | |
dc.identifier.doi | 10.1118/1.1851920 | |
dc.identifier.source | Medical Physics | |
dc.identifier.citedreference | R. C. Zellars, P. L. Roberson, M. Strawderman, D. Zhang, H. Sandler, R. K. Ten Haken, D. Osher, and P. W. McLaughlin, “ Prostate position late in the course of external beam therapy: Patterns and predictors,” Int. J. Radiat. Oncol., Biol., Phys. IOBPD3 --> 0360‐3016 --> 47, 655 – 660 ( 2000 ). | |
dc.identifier.citedreference | D. F. Dubois, W. S. Bice, and B. R. Prestidge, “ CT and MRI derived source localization error in a custom prostate phantom using automated image coregistration,” Med. Phys. MPHYA6 --> 0094‐2405 --> 28, 2280 – 2284 ( 2001 ). | |
dc.identifier.citedreference | J. J. Prete, B. R. Prestidge, W. S. Bice, D. F. Dubois, and L. A. Hotchkiss, “ Comparison of MRI‐ and CT‐based post‐implant dosimetric analysis of transperineal interstitial permanent prostate brachytherapy,” Radiat. Oncol. Invest. ROINEU --> 1065‐7541 --> 6, 90 – 96 ( 1998 ). | |
dc.identifier.citedreference | P. Bourel, D. Gibon, E. Coste, V. Daanen, and J. Rousseau, “ Automatic quality assessment protocol for MRI equipment,” Med. Phys. MPHYA6 --> 0094‐2405 --> 26, 2693 – 2700 ( 1999 ). | |
dc.identifier.citedreference | S. Nag, W. Bice, K. deWyngaert, B. Prestidge, R. Stock, and Y. Yu, “ The American Brachytherapy Society recommendations for permanent prostate brachytherapy postimplant dosimetric analysis,” Int. J. Radiat. Oncol., Biol., Phys. IOBPD3 --> 0360‐3016 --> 46, 221 – 230 ( 2000 ). | |
dc.identifier.citedreference | M. Roach, P. Faillace‐Akazawa, C. Malfatti, J. Holland, and H. Hricak, “ Prostate volumes defined by magnetic resonance imaging and computerized tomographic scans for three‐dimensional conformal radiotherapy,” Int. J. Radiat. Oncol., Biol., Phys. IOBPD3 --> 0360‐3016 --> 35, 1011 – 1018 ( 1996 ). | |
dc.identifier.citedreference | P. W. McLaughlin, V. Narayana, D. G. Drake, B. M. Miller, L. Marsh, J. Chan, R. Gonda, Jr., R. J. Winfield, and P. L. Roberson, “ Comparison of MRI pulse sequences in defining prostate volume after permanent implantation,” Int. J. Radiat. Oncol., Biol., Phys. IOBPD3 --> 0360‐3016 --> 54, 703 – 711 ( 2002 ). | |
dc.identifier.citedreference | D. L. McShan, R. K. Ten Haken, and B. A. Fraass, “ 3D Treatment planning: IV integrated brachytherapy planning,” in The Use of Computers in Radiation Therapy, edited by I. A. D. Bruinvis et al. ( Elsevier Science Publishers B.V., North‐Holland, 1987 ). | |
dc.identifier.citedreference | R. J. Amdur, D. Gladstone, K. A. Leopold, and R. D. Harris, “ Prostate seed implant quality assessment using MR and CT image fusion,” Int. J. Radiat. Oncol., Biol., Phys. IOBPD3 --> 0360‐3016 --> 43, 67 – 72 ( 1999 ). | |
dc.identifier.citedreference | D. F. Dubois, B. R. Prestidge, L. A. Hotchkiss, J. J. Prete, and W. S. Bice, Jr., “ Intraobserver and interobserver variability of MR imaging and CT‐derived prostate volumes after transperineal interstitial permanent prostate brachytherapy,” Radiology RADLAX --> 0033‐8419 --> 207, 785 – 789 ( 1998 ). | |
dc.identifier.citedreference | D. F. Dubois, B. R. Prestidge, L. A. Hotchkiss, W. S. Bice, Jr., and J. J. Prete, “ Source localization following permanent transperineal prostate interstitial brachytherapy using magnetic resonance imaging,” Int. J. Radiat. Oncol., Biol., Phys. IOBPD3 --> 0360‐3016 --> 39, 1037 – 41 ( 1997 ). | |
dc.identifier.citedreference | M. Milosevic, S. Voruganti, R. Blend, H. Alasti, P. Warde, M. Mclean, P. Catton, C. Catton, and M. Gospodarowicz, “ Magnetic resonance imaging (MRI) for localization of the prostate apex: comparison to computed tomography (CT) and urethrography,” Radiother. Oncol. RAONDT --> 0167‐8140 --> 47, 277 – 284 ( 1998 ). | |
dc.identifier.citedreference | F. Maes, A. Collignon, D. Vandermeulen, G. Marchal, and P. Suetens, “ Multimodality image registration by maximization of mutual information,” IEEE Trans. Med. Imaging ITMID4 --> 0278‐0062 --> 16, 187 – 198 ( 1997 ). | |
dc.identifier.citedreference | W. M. Wells, P. Viola, H. Atsume, S. Nakajima, and R. Kikinis, “ Multimedia volume registration by maximization of mutual information,” Med. Image Anal. MITEET --> 0288‐450X --> 1, 35 – 51 ( 1996 ). | |
dc.owningcollname | Interdisciplinary and Peer-Reviewed |
Files in this item
Remediation of Harmful Language
The University of Michigan Library aims to describe library materials in a way that respects the people and communities who create, use, and are represented in our collections. Report harmful or offensive language in catalog records, finding aids, or elsewhere in our collections anonymously through our metadata feedback form. More information at Remediation of Harmful Language.
Accessibility
If you are unable to use this file in its current format, please select the Contact Us link and we can modify it to make it more accessible to you.