Show simple item record

Comparison of similarity measures for the task of template matching of masses on serial mammograms

dc.contributor.authorFilev, Peter
dc.contributor.authorHadjiiski, Lubomir
dc.contributor.authorSahiner, Berkman
dc.contributor.authorChan, Heang‐ping
dc.contributor.authorHelvie, Mark A.
dc.date.accessioned2017-01-06T20:47:14Z
dc.date.available2017-01-06T20:47:14Z
dc.date.issued2005-02
dc.identifier.citationFilev, Peter; Hadjiiski, Lubomir; Sahiner, Berkman; Chan, Heang‐ping ; Helvie, Mark A. (2005). "Comparison of similarity measures for the task of template matching of masses on serial mammograms." Medical Physics 32(2): 515-529.
dc.identifier.issn0094-2405
dc.identifier.issn2473-4209
dc.identifier.urihttps://hdl.handle.net/2027.42/134879
dc.publisherAmerican Association of Physicists in Medicine
dc.publisherWiley Periodicals, Inc.
dc.subject.otherComputer aided diagnosis
dc.subject.otherimage registration
dc.subject.othermedical image processing
dc.subject.otherimage matching
dc.subject.othermammography
dc.subject.otherImage analysis
dc.subject.otherMammography
dc.subject.otherBrightness
dc.subject.otherVector currents
dc.subject.otherCalibration
dc.subject.otherTime measurement
dc.subject.otherFilm mammography
dc.subject.otherRadiologists
dc.subject.otherMedical imaging
dc.subject.otherElectric measurements
dc.subject.otherMammography
dc.subject.othertumours
dc.subject.othercancer
dc.titleComparison of similarity measures for the task of template matching of masses on serial mammograms
dc.typeArticleen_US
dc.rights.robotsIndexNoFollow
dc.subject.hlbsecondlevelMedicine (General)
dc.subject.hlbtoplevelHealth Sciences
dc.description.peerreviewedPeer Reviewed
dc.contributor.affiliationumDepartment of Radiology, The University of Michigan, Ann Arbor, Michigan 48109â 0904
dc.description.bitstreamurlhttp://deepblue.lib.umich.edu/bitstream/2027.42/134879/1/mp1892.pdf
dc.identifier.doi10.1118/1.1851892
dc.identifier.sourceMedical Physics
dc.identifier.citedreferenceS. Sanjayâ Gopal, H. P. Chan, T. Wilson, M. Helvie, N. Petrick, and B. Sahiner, â A regional registration technique for automated interval change analysis of breast lesions on mammograms,â Med. Phys. MPHYA6 --> 0094‐2405 --> 26, 2669 â 2679 ( 1999 ).
dc.identifier.citedreferenceN. Vujovic and D. Brzakovic, â Establishing the correspondence between control points in pairs of mammographic images,â IEEE Trans. Image Process. IIPRE4 --> 1057‐7149 --> 6, 1388 â 1399 ( 1997 ).
dc.identifier.citedreferenceM. Sallam and K. Bowyer, â Detecting abnormal densities in mammograms by comparison with previous screenings,â in Digital Mammography â 96, edited by K. Doi, M. L. Giger, R. M. Nishikawa, and R. A. Schmidt ( Elsevier, Amsterdam, 1996 ).
dc.identifier.citedreferenceL. Hamers, Y. Hemeryck, G. Herweyers, M. Janssen, H. Keters, R. Rousseau, and A. Vanhoutte, â Similarity measures in scientometric research: The Jaccard index versus Salton’s cosine formula,â Inf. Process. Management zzzzzz --> 25, 315 â 318 ( 1989 ).
dc.identifier.citedreferenceA. Agresti, â The effect of category choice on some ordinal measures of association,â J. Am. Stat. Assoc. 0162‐1459 --> 71, 49 â 55 ( 1976 ).
dc.identifier.citedreferenceL. A. Goodman and W. H. Kruskal, â Measures of association for crossâ classification,â J. Am. Stat. Assoc. 0162‐1459 --> 49, 732 â 764 ( 1954 ).
dc.identifier.citedreferenceB. M. Sarwar, G. Karypis, J. A. Konstan, and J. Riedl, â Itemâ based collaborative filtering recommendation algorithms,â Proc. of the 10th International World Wide Web Conference, Hong Kong, May 2001, pp. 285 â 295 ( 2001 ).
dc.identifier.citedreferenceJ. Banks and M. Bennamoun, â Reliability analysis of the rank transform for stereo matching,â IEEE Trans. Syst. Man Cybern. ISYMAW --> 0018‐9472 --> 31, 870 â 880 ( 2001 ).
dc.identifier.citedreferenceD. N. Bhat and S. K. Nayar, â Ordinal measures for image correspondence,â IEEE Trans. Pattern Anal. Mach. Intell. ITPIDJ --> 0162‐8828 --> 20, 415 â 423 ( 1998 ).
dc.identifier.citedreferenceG. P. Penney, J. Weese, J. A. Little, P. Desmedt, D. L. Hill, and D. J. Hawkes, â A comparison of similarity measures for use in 2â Dâ 3â D medical image registration,â IEEE Trans. Med. Imaging ITMID4 --> 0278‐0062 --> 17, 586 â 595 ( 1998 ).
dc.identifier.citedreferenceS. Kaneko, I. Murase, and S. Igarashi, â Robust image registration by increment sign correlation,â Pattern Recogn. PTNRA8 --> 0031‐3203 --> 35, 2223 â 2234 ( 2001 ).
dc.identifier.citedreferenceJ. P. W. Pluim, J. B. Antoine Maintz, and M. A. Viergever, â Mutualâ informationâ based registration of medical images: A survey,â IEEE Trans. Med. Imaging ITMID4 --> 0278‐0062 --> 22, 986 â 1004 ( 2003 ).
dc.identifier.citedreferenceF. Maes, A. Collignon, D. Vandermeulen, G. Marchal, and P. Suetens, â Multimodality image registration by maximization of mutual information,â IEEE Trans. Med. Imaging ITMID4 --> 0278‐0062 --> 16, 187 â 198 ( 1997 ).
dc.identifier.citedreferenceC. R. Meyer, J. L. Boes, B. Kim, P. Bland, K. R. Zasadny, P. C. Kison, K. Koral, K. A. Frey, and R. L. Wahl, â Demonstration of accuracy and clinical versatility of mutual information for automatic multimodality image fusion using affine and thin plate spline warped geometric deformations,â Med. Image Anal 1361‐8415 --> 3, 195 â 206 ( 1997 ).
dc.identifier.citedreferenceL. M. Hadjiiski, H. P. Chan, B. Sahiner, C. Zhou, M. A. Helvie, and M. A. Roubidoux, â Computerized Regional Registration of Corresponding Masses and Microcalcification Clusters on Temporal Pairs of Mammograms for Interval Change Analysis,â Presented at the 89th Scientific Assembly and Annual Meeting of the Radiological Society of North America, Chicago, IL, November 30â December 5, 2003, 389.
dc.identifier.citedreferenceS. Van Engeland, P. Snoeren, J. Hendriks, and N. Karssemeijer, â A comparison of methods for mammogram registration,â IEEE Trans. Med. Imaging ITMID4 --> 0278‐0062 --> 22, 1436 â 1444 ( 2003 ).
dc.identifier.citedreferenceB. Zheng, W. F. Good, D. R. Armfield, C. Cohen, T. Hertzberg, J. H. Sumkin, and D. Gur, â Performance change of mammographic CAD schemes optimized with mostâ recent and prior image databases,â Acad. Radiol. 1076‐6332 --> 10, 283 â 288 ( 2003 ).
dc.identifier.citedreferenceL. M. Hadjiiski, H. P. Chan, B. Sahiner, N. Petrick, and M. A. Helvie, â Automated registration of breast lesions in temporal pairs of mammograms for interval change analysisâ local affine transformation for improved localization,â Med. Phys. MPHYA6 --> 0094‐2405 --> 28, 1070 â 1079 ( 2001 ).
dc.identifier.citedreferenceW. F. Good, B. Zheng, Y. H. Chang, Z. H. Wang, and G. S. Maitz, â Generalized procrustean image deformation for substraction of mammograms,â Proc. SPIE PSISDG --> 0277‐786X --> 3661, 1562 â 1573 ( 1999 ).
dc.identifier.citedreferenceL. M. Hadjiiski, H. P. Chan, B. Sahiner, N. Petrick, M. A. Helvie, and S. Sanjayâ Gopal, â Automated identification of breast lesions in temporal pairs of mammograms for interval change analysis,â Radiology RADLAX --> 0033‐8419 --> 213 (P), 229 â 230 ( 1999 ).
dc.owningcollnameInterdisciplinary and Peer-Reviewed


Files in this item

Show simple item record

Remediation of Harmful Language

The University of Michigan Library aims to describe library materials in a way that respects the people and communities who create, use, and are represented in our collections. Report harmful or offensive language in catalog records, finding aids, or elsewhere in our collections anonymously through our metadata feedback form. More information at Remediation of Harmful Language.

Accessibility

If you are unable to use this file in its current format, please select the Contact Us link and we can modify it to make it more accessible to you.