Show simple item record

Computerâ aided detection of breast masses on mammograms: Dual system approach with twoâ view analysis

dc.contributor.authorWei, Jun
dc.contributor.authorChan, Heang‐ping
dc.contributor.authorSahiner, Berkman
dc.contributor.authorZhou, Chuan
dc.contributor.authorHadjiiski, Lubomir M.
dc.contributor.authorRoubidoux, Marilyn A.
dc.contributor.authorHelvie, Mark A.
dc.date.accessioned2017-01-06T20:47:41Z
dc.date.available2017-01-06T20:47:41Z
dc.date.issued2009-10
dc.identifier.citationWei, Jun; Chan, Heang‐ping ; Sahiner, Berkman; Zhou, Chuan; Hadjiiski, Lubomir M.; Roubidoux, Marilyn A.; Helvie, Mark A. (2009). "Computerâ aided detection of breast masses on mammograms: Dual system approach with twoâ view analysis." Medical Physics 36(10): 4451-4460.
dc.identifier.issn0094-2405
dc.identifier.issn2473-4209
dc.identifier.urihttps://hdl.handle.net/2027.42/134905
dc.publisherWiley Periodicals, Inc.
dc.publisherAmerican Association of Physicists in Medicine
dc.subject.otherMammography
dc.subject.otherfeature extraction
dc.subject.otherRegistration
dc.subject.otherComputerâ aided diagnosis
dc.subject.otherCancer
dc.subject.otherImage analysis
dc.subject.otherTesting procedures
dc.subject.otherRadiologists
dc.subject.otherInformation integration
dc.subject.otherLaser Doppler velocimetry
dc.subject.otherFilm mammography
dc.subject.otherImage detection systems
dc.subject.otherMedical imaging
dc.subject.otherMammography
dc.subject.otherfalse positive reduction
dc.subject.otherbreast mass
dc.subject.othercomputerâ aided detection
dc.subject.othermedical image processing
dc.subject.othermammography
dc.subject.otherimage registration
dc.subject.otherimage fusion
dc.subject.otherimage classification
dc.titleComputerâ aided detection of breast masses on mammograms: Dual system approach with twoâ view analysis
dc.typeArticleen_US
dc.rights.robotsIndexNoFollow
dc.subject.hlbsecondlevelMedicine (General)
dc.subject.hlbtoplevelHealth Sciences
dc.description.peerreviewedPeer Reviewed
dc.contributor.affiliationumDepartment of Radiology, University of Michigan, 1500 E. Medical Center Drive, Med Inn Building C478, Ann Arbor, Michigan 48109â 5842
dc.description.bitstreamurlhttp://deepblue.lib.umich.edu/bitstream/2027.42/134905/1/mp0669.pdf
dc.identifier.doi10.1118/1.3220669
dc.identifier.sourceMedical Physics
dc.identifier.citedreferenceS. Paquerault, B. Sahiner, N. Petrick, L. M. Hadjiiski, M. N. Gurcan, C. Zhou, and M. A. Helvie, â Prediction of object location in different views using geometrical models,â presented at the IWDMâ 2000, Toronto, Canada, June 11â 14, 2000; in Digital Mammography IWDM 2000: 5th International Workshop on Digital Mammography, edited by M. J. Yaffe ( Medical Physics, Madison, WI, 2000 ), pp. 748 â 755.
dc.identifier.citedreferenceS. Paquerault, N. Petrick, H. P. Chan, B. Sahiner, and M. A. Helvie, â Improvement of computerized mass detection on mammograms: Fusion of twoâ view information,â Med. Phys. MPHYA6 --> 0094‐2405 --> 29, 238 â 247 ( 2002 ). 10.1118/1.1446098
dc.identifier.citedreferenceY. Kita, R. P. Highnam, and J. M. Brady, â Correspondence between different view breast x rays using curved epipolar lines,â Comput. Vis. Image Underst. CVIUF4 --> 1077‐3142 --> 83, 38 â 56 ( 2001 ). 10.1006/cviu.2001.0908
dc.identifier.citedreferenceR. Warren, S. Duffy, and S. Bashir, â The value of the second view in screening mammography,â Br. J. Radiol. BJRAAP --> 0007‐1285 --> 69, 105 â 108 ( 1996 ). 10.1259/0007â 1285â 69â 818â 105
dc.identifier.citedreferenceE. Thurfjell, A. Taube, and L. Tabar, â Oneâ view versus 2â view mammography screeningâ A prospective populationâ based study,â Acta Radiol. ACRAE3 --> 0284‐1851 --> 35, 340 â 344 ( 1994 ).
dc.identifier.citedreferenceT. V. Perneger, â What’s wrong with Bonferroni adjustments,â Br. Med. J. BMJOAE --> 0007‐1447 --> 316, 1236 â 1238 ( 1998 ).
dc.identifier.citedreferenceJ. P. Shaffer, â Multiple hypothesis testing,â Annu. Rev. Psychol. ARPSAC --> 0066‐4308 --> 46, 561 â 584 ( 1995 ). 10.1146/annurev.ps.46.020195.003021
dc.identifier.citedreferenceD. P. Chakraborty, â Validation and statistical power comparison of methods for analyzing freeâ response observer performance studies,â Acad. Radiol. 1076‐6332 --> 15, 1554 â 1566 ( 2008 ). 10.1016/j.acra.2008.07.018
dc.identifier.citedreferenceM. J. Norusis, SPSS for Windows Release 6 Professional Statistics ( SPSS, Chicago, IL, 1993 ).
dc.identifier.citedreferenceL. M. Hadjiiski, B. Sahiner, H. P. Chan, N. Petrick, M. A. Helvie, and M. N. Gurcan, â Analysis of temporal change of mammographic features: Computerâ aided classification of malignant and benign breast masses,â Med. Phys. MPHYA6 --> 0094‐2405 --> 28, 2309 â 2317 ( 2001 ). 10.1118/1.1412242
dc.identifier.citedreferenceH. P. Chan, D. Wei, M. A. Helvie, B. Sahiner, D. D. Adler, M. M. Goodsitt, and N. Petrick, â Computerâ aided classification of mammographic masses and normal tissue: Linear discriminant analysis in texture feature space,â Phys. Med. Biol. PHMBA7 --> 0031‐9155 --> 40, 857 â 876 ( 1995 ). 10.1088/0031â 9155/40/5/010
dc.identifier.citedreferenceB. Sahiner, H. P. Chan, N. Petrick, M. A. Helvie, and M. M. Goodsitt, â Computerized characterization of masses on mammograms: The rubber band straightening transform and texture analysis,â Med. Phys. MPHYA6 --> 0094‐2405 --> 25, 516 â 526 ( 1998 ). 10.1118/1.598228
dc.identifier.citedreferenceB. Sahiner, H. P. Chan, N. Petrick, M. A. Helvie, and L. M. Hadjiiski, â Improvement of mammographic mass characterization using spiculation measures and morphological features,â Med. Phys. MPHYA6 --> 0094‐2405 --> 28, 1455 â 1465 ( 2001 ). 10.1118/1.1381548
dc.identifier.citedreferenceP. Filev, L. M. Hadjiiski, B. Sahiner, H. P. Chan, and M. A. Helvie, â Comparison of similarity measures for the task of template matching of masses on serial mammograms,â Med. Phys. MPHYA6 --> 0094‐2405 --> 32, 515 â 529 ( 2005 ). 10.1118/1.1851892
dc.identifier.citedreferenceC. Zhou, H.â P. Chan, C. Paramagul, M. A. Roubidoux, B. Sahiner, L. M. Hadjiiski, and N. Petrick, â Computerized nipple identification for multiple image analysis in computerâ aided diagnosis,â Med. Phys. MPHYA6 --> 0094‐2405 --> 31, 2871 â 2882 ( 2004 ). 10.1118/1.1800713
dc.identifier.citedreferenceJ. Wei, B. Sahiner, L. M. Hadjiiski, H.â P. Chan, M. A. Helvie, M. A. Roubidoux, C. Zhou, J. Ge, and Y. Zhang, â Twoâ view information fusion for improvement of computerâ aided detection (CAD) of breast masses on mammograms,â Proc. SPIE PSISDG --> 0277‐786X --> 6144, 241 â 247 ( 2006 ).
dc.identifier.citedreferenceJ. Wei, H.â P. Chan, B. Sahiner, L. M. Hadjiiski, M. A. Helvie, M. A. Roubidoux, C. Zhou, and J. Ge, â Dual system approach to computerâ aided detection of breast masses on mammograms,â Med. Phys. MPHYA6 --> 0094‐2405 --> 33, 4157 â 4168 ( 2006 ). 10.1118/1.2357838
dc.identifier.citedreferenceJ. Wei et al., â Computer aided detection systems for breast masses: Comparison of performances on fullâ field digital mammograms and digitized screenâ film mammograms,â Acad. Radiol. 1076‐6332 --> 6, 659 â 669 ( 2007 ). 10.1016/j.acra.2007.02.017
dc.identifier.citedreferenceJ. Wei, B. Sahiner, L. M. Hadjiiski, H. P. Chan, N. Petrick, M. A. Helvie, M. A. Roubidoux, J. Ge, and C. Zhou, â Computer aided detection of breast masses on full field digital mammograms,â Med. Phys. MPHYA6 --> 0094‐2405 --> 32, 2827 â 2838 ( 2005 ). 10.1118/1.1997327
dc.identifier.citedreferenceM. Velikova, M. Samulski, P. J. F. Lucas, and N. Karssemeijer, â Improved mammographic CAD performance using multiâ view information: A Bayesian network framework,â Phys. Med. Biol. PHMBA7 --> 0031‐9155 --> 54, 1131 â 1147 ( 2009 ). 10.1088/0031â 9155/54/5/003
dc.identifier.citedreferenceW. Qian, D. S. Song, M. S. Lei, R. Sankar, and E. Eikman, â Computerâ aided mass detection based on ipsilateral multiview mammograms,â Acad. Radiol. 1076‐6332 --> 14, 530 â 538 ( 2007 ). 10.1016/j.acra.2007.01.012
dc.identifier.citedreferenceB. Zheng, J. K. Leader, G. S. Abrams, A. H. Lu, L. P. Wallace, G. S. Maitz, and D. Gur, â Multiviewâ based computerâ aided detection scheme for breast masses,â Med. Phys. MPHYA6 --> 0094‐2405 --> 33, 3135 â 3143 ( 2006 ). 10.1118/1.2237476
dc.identifier.citedreferenceB. Sahiner, H.â P. Chan, L. M. Hadjiiski, M. A. Helvie, C. Paramagul, J. Ge, J. Wei, and C. Zhou, â Joint twoâ view information for computerized detection of microcalcifications on mammograms,â Med. Phys. MPHYA6 --> 0094‐2405 --> 33, 2574 â 2585 ( 2006 ). 10.1118/1.2208919
dc.identifier.citedreferenceS. van Engeland and N. Karssemeijer, â Combining two mammographic projections in a computer aided mass detection method,â Med. Phys. MPHYA6 --> 0094‐2405 --> 34, 898 â 905 ( 2007 ). 10.1118/1.2436974
dc.owningcollnameInterdisciplinary and Peer-Reviewed


Files in this item

Show simple item record

Remediation of Harmful Language

The University of Michigan Library aims to describe library materials in a way that respects the people and communities who create, use, and are represented in our collections. Report harmful or offensive language in catalog records, finding aids, or elsewhere in our collections anonymously through our metadata feedback form. More information at Remediation of Harmful Language.

Accessibility

If you are unable to use this file in its current format, please select the Contact Us link and we can modify it to make it more accessible to you.