Computerâ aided detection of breast masses on mammograms: Dual system approach with twoâ view analysis
dc.contributor.author | Wei, Jun | |
dc.contributor.author | Chan, Heang‐ping | |
dc.contributor.author | Sahiner, Berkman | |
dc.contributor.author | Zhou, Chuan | |
dc.contributor.author | Hadjiiski, Lubomir M. | |
dc.contributor.author | Roubidoux, Marilyn A. | |
dc.contributor.author | Helvie, Mark A. | |
dc.date.accessioned | 2017-01-06T20:47:41Z | |
dc.date.available | 2017-01-06T20:47:41Z | |
dc.date.issued | 2009-10 | |
dc.identifier.citation | Wei, Jun; Chan, Heang‐ping ; Sahiner, Berkman; Zhou, Chuan; Hadjiiski, Lubomir M.; Roubidoux, Marilyn A.; Helvie, Mark A. (2009). "Computerâ aided detection of breast masses on mammograms: Dual system approach with twoâ view analysis." Medical Physics 36(10): 4451-4460. | |
dc.identifier.issn | 0094-2405 | |
dc.identifier.issn | 2473-4209 | |
dc.identifier.uri | https://hdl.handle.net/2027.42/134905 | |
dc.publisher | Wiley Periodicals, Inc. | |
dc.publisher | American Association of Physicists in Medicine | |
dc.subject.other | Mammography | |
dc.subject.other | feature extraction | |
dc.subject.other | Registration | |
dc.subject.other | Computerâ aided diagnosis | |
dc.subject.other | Cancer | |
dc.subject.other | Image analysis | |
dc.subject.other | Testing procedures | |
dc.subject.other | Radiologists | |
dc.subject.other | Information integration | |
dc.subject.other | Laser Doppler velocimetry | |
dc.subject.other | Film mammography | |
dc.subject.other | Image detection systems | |
dc.subject.other | Medical imaging | |
dc.subject.other | Mammography | |
dc.subject.other | false positive reduction | |
dc.subject.other | breast mass | |
dc.subject.other | computerâ aided detection | |
dc.subject.other | medical image processing | |
dc.subject.other | mammography | |
dc.subject.other | image registration | |
dc.subject.other | image fusion | |
dc.subject.other | image classification | |
dc.title | Computerâ aided detection of breast masses on mammograms: Dual system approach with twoâ view analysis | |
dc.type | Article | en_US |
dc.rights.robots | IndexNoFollow | |
dc.subject.hlbsecondlevel | Medicine (General) | |
dc.subject.hlbtoplevel | Health Sciences | |
dc.description.peerreviewed | Peer Reviewed | |
dc.contributor.affiliationum | Department of Radiology, University of Michigan, 1500 E. Medical Center Drive, Med Inn Building C478, Ann Arbor, Michigan 48109â 5842 | |
dc.description.bitstreamurl | http://deepblue.lib.umich.edu/bitstream/2027.42/134905/1/mp0669.pdf | |
dc.identifier.doi | 10.1118/1.3220669 | |
dc.identifier.source | Medical Physics | |
dc.identifier.citedreference | S. Paquerault, B. Sahiner, N. Petrick, L. M. Hadjiiski, M. N. Gurcan, C. Zhou, and M. A. Helvie, â Prediction of object location in different views using geometrical models,â presented at the IWDMâ 2000, Toronto, Canada, June 11â 14, 2000; in Digital Mammography IWDM 2000: 5th International Workshop on Digital Mammography, edited by M. J. Yaffe ( Medical Physics, Madison, WI, 2000 ), pp. 748 â 755. | |
dc.identifier.citedreference | S. Paquerault, N. Petrick, H. P. Chan, B. Sahiner, and M. A. Helvie, â Improvement of computerized mass detection on mammograms: Fusion of twoâ view information,â Med. Phys. MPHYA6 --> 0094‐2405 --> 29, 238 â 247 ( 2002 ). 10.1118/1.1446098 | |
dc.identifier.citedreference | Y. Kita, R. P. Highnam, and J. M. Brady, â Correspondence between different view breast x rays using curved epipolar lines,â Comput. Vis. Image Underst. CVIUF4 --> 1077‐3142 --> 83, 38 â 56 ( 2001 ). 10.1006/cviu.2001.0908 | |
dc.identifier.citedreference | R. Warren, S. Duffy, and S. Bashir, â The value of the second view in screening mammography,â Br. J. Radiol. BJRAAP --> 0007‐1285 --> 69, 105 â 108 ( 1996 ). 10.1259/0007â 1285â 69â 818â 105 | |
dc.identifier.citedreference | E. Thurfjell, A. Taube, and L. Tabar, â Oneâ view versus 2â view mammography screeningâ A prospective populationâ based study,â Acta Radiol. ACRAE3 --> 0284‐1851 --> 35, 340 â 344 ( 1994 ). | |
dc.identifier.citedreference | T. V. Perneger, â What’s wrong with Bonferroni adjustments,â Br. Med. J. BMJOAE --> 0007‐1447 --> 316, 1236 â 1238 ( 1998 ). | |
dc.identifier.citedreference | J. P. Shaffer, â Multiple hypothesis testing,â Annu. Rev. Psychol. ARPSAC --> 0066‐4308 --> 46, 561 â 584 ( 1995 ). 10.1146/annurev.ps.46.020195.003021 | |
dc.identifier.citedreference | D. P. Chakraborty, â Validation and statistical power comparison of methods for analyzing freeâ response observer performance studies,â Acad. Radiol. 1076‐6332 --> 15, 1554 â 1566 ( 2008 ). 10.1016/j.acra.2008.07.018 | |
dc.identifier.citedreference | M. J. Norusis, SPSS for Windows Release 6 Professional Statistics ( SPSS, Chicago, IL, 1993 ). | |
dc.identifier.citedreference | L. M. Hadjiiski, B. Sahiner, H. P. Chan, N. Petrick, M. A. Helvie, and M. N. Gurcan, â Analysis of temporal change of mammographic features: Computerâ aided classification of malignant and benign breast masses,â Med. Phys. MPHYA6 --> 0094‐2405 --> 28, 2309 â 2317 ( 2001 ). 10.1118/1.1412242 | |
dc.identifier.citedreference | H. P. Chan, D. Wei, M. A. Helvie, B. Sahiner, D. D. Adler, M. M. Goodsitt, and N. Petrick, â Computerâ aided classification of mammographic masses and normal tissue: Linear discriminant analysis in texture feature space,â Phys. Med. Biol. PHMBA7 --> 0031‐9155 --> 40, 857 â 876 ( 1995 ). 10.1088/0031â 9155/40/5/010 | |
dc.identifier.citedreference | B. Sahiner, H. P. Chan, N. Petrick, M. A. Helvie, and M. M. Goodsitt, â Computerized characterization of masses on mammograms: The rubber band straightening transform and texture analysis,â Med. Phys. MPHYA6 --> 0094‐2405 --> 25, 516 â 526 ( 1998 ). 10.1118/1.598228 | |
dc.identifier.citedreference | B. Sahiner, H. P. Chan, N. Petrick, M. A. Helvie, and L. M. Hadjiiski, â Improvement of mammographic mass characterization using spiculation measures and morphological features,â Med. Phys. MPHYA6 --> 0094‐2405 --> 28, 1455 â 1465 ( 2001 ). 10.1118/1.1381548 | |
dc.identifier.citedreference | P. Filev, L. M. Hadjiiski, B. Sahiner, H. P. Chan, and M. A. Helvie, â Comparison of similarity measures for the task of template matching of masses on serial mammograms,â Med. Phys. MPHYA6 --> 0094‐2405 --> 32, 515 â 529 ( 2005 ). 10.1118/1.1851892 | |
dc.identifier.citedreference | C. Zhou, H.â P. Chan, C. Paramagul, M. A. Roubidoux, B. Sahiner, L. M. Hadjiiski, and N. Petrick, â Computerized nipple identification for multiple image analysis in computerâ aided diagnosis,â Med. Phys. MPHYA6 --> 0094‐2405 --> 31, 2871 â 2882 ( 2004 ). 10.1118/1.1800713 | |
dc.identifier.citedreference | J. Wei, B. Sahiner, L. M. Hadjiiski, H.â P. Chan, M. A. Helvie, M. A. Roubidoux, C. Zhou, J. Ge, and Y. Zhang, â Twoâ view information fusion for improvement of computerâ aided detection (CAD) of breast masses on mammograms,â Proc. SPIE PSISDG --> 0277‐786X --> 6144, 241 â 247 ( 2006 ). | |
dc.identifier.citedreference | J. Wei, H.â P. Chan, B. Sahiner, L. M. Hadjiiski, M. A. Helvie, M. A. Roubidoux, C. Zhou, and J. Ge, â Dual system approach to computerâ aided detection of breast masses on mammograms,â Med. Phys. MPHYA6 --> 0094‐2405 --> 33, 4157 â 4168 ( 2006 ). 10.1118/1.2357838 | |
dc.identifier.citedreference | J. Wei et al., â Computer aided detection systems for breast masses: Comparison of performances on fullâ field digital mammograms and digitized screenâ film mammograms,â Acad. Radiol. 1076‐6332 --> 6, 659 â 669 ( 2007 ). 10.1016/j.acra.2007.02.017 | |
dc.identifier.citedreference | J. Wei, B. Sahiner, L. M. Hadjiiski, H. P. Chan, N. Petrick, M. A. Helvie, M. A. Roubidoux, J. Ge, and C. Zhou, â Computer aided detection of breast masses on full field digital mammograms,â Med. Phys. MPHYA6 --> 0094‐2405 --> 32, 2827 â 2838 ( 2005 ). 10.1118/1.1997327 | |
dc.identifier.citedreference | M. Velikova, M. Samulski, P. J. F. Lucas, and N. Karssemeijer, â Improved mammographic CAD performance using multiâ view information: A Bayesian network framework,â Phys. Med. Biol. PHMBA7 --> 0031‐9155 --> 54, 1131 â 1147 ( 2009 ). 10.1088/0031â 9155/54/5/003 | |
dc.identifier.citedreference | W. Qian, D. S. Song, M. S. Lei, R. Sankar, and E. Eikman, â Computerâ aided mass detection based on ipsilateral multiview mammograms,â Acad. Radiol. 1076‐6332 --> 14, 530 â 538 ( 2007 ). 10.1016/j.acra.2007.01.012 | |
dc.identifier.citedreference | B. Zheng, J. K. Leader, G. S. Abrams, A. H. Lu, L. P. Wallace, G. S. Maitz, and D. Gur, â Multiviewâ based computerâ aided detection scheme for breast masses,â Med. Phys. MPHYA6 --> 0094‐2405 --> 33, 3135 â 3143 ( 2006 ). 10.1118/1.2237476 | |
dc.identifier.citedreference | B. Sahiner, H.â P. Chan, L. M. Hadjiiski, M. A. Helvie, C. Paramagul, J. Ge, J. Wei, and C. Zhou, â Joint twoâ view information for computerized detection of microcalcifications on mammograms,â Med. Phys. MPHYA6 --> 0094‐2405 --> 33, 2574 â 2585 ( 2006 ). 10.1118/1.2208919 | |
dc.identifier.citedreference | S. van Engeland and N. Karssemeijer, â Combining two mammographic projections in a computer aided mass detection method,â Med. Phys. MPHYA6 --> 0094‐2405 --> 34, 898 â 905 ( 2007 ). 10.1118/1.2436974 | |
dc.owningcollname | Interdisciplinary and Peer-Reviewed |
Files in this item
Remediation of Harmful Language
The University of Michigan Library aims to describe library materials in a way that respects the people and communities who create, use, and are represented in our collections. Report harmful or offensive language in catalog records, finding aids, or elsewhere in our collections anonymously through our metadata feedback form. More information at Remediation of Harmful Language.
Accessibility
If you are unable to use this file in its current format, please select the Contact Us link and we can modify it to make it more accessible to you.