Segmented crystalline scintillators: An initial investigation of high quantum efficiency detectors for megavoltage xâ ray imaging
dc.contributor.author | Sawant, Amit | |
dc.contributor.author | Antonuk, Larry E. | |
dc.contributor.author | El‐mohri, Youcef | |
dc.contributor.author | Zhao, Qihua | |
dc.contributor.author | Li, Yixin | |
dc.contributor.author | Su, Zhong | |
dc.contributor.author | Wang, Yi | |
dc.contributor.author | Yamamoto, Jin | |
dc.contributor.author | Du, Hong | |
dc.contributor.author | Cunningham, Ian | |
dc.contributor.author | Klugerman, Misha | |
dc.contributor.author | Shah, Kanai | |
dc.date.accessioned | 2017-01-06T20:48:09Z | |
dc.date.available | 2017-01-06T20:48:09Z | |
dc.date.issued | 2005-10 | |
dc.identifier.citation | Sawant, Amit; Antonuk, Larry E.; El‐mohri, Youcef ; Zhao, Qihua; Li, Yixin; Su, Zhong; Wang, Yi; Yamamoto, Jin; Du, Hong; Cunningham, Ian; Klugerman, Misha; Shah, Kanai (2005). "Segmented crystalline scintillators: An initial investigation of high quantum efficiency detectors for megavoltage xâ ray imaging." Medical Physics 32(10): 3067-3083. | |
dc.identifier.issn | 0094-2405 | |
dc.identifier.issn | 2473-4209 | |
dc.identifier.uri | https://hdl.handle.net/2027.42/134936 | |
dc.publisher | American Association of Physicists in Medicine | |
dc.publisher | Wiley Periodicals, Inc. | |
dc.subject.other | portal imaging | |
dc.subject.other | flat panel imager | |
dc.subject.other | DQE | |
dc.subject.other | Scintillation detectors | |
dc.subject.other | Medical imaging | |
dc.subject.other | Image sensors | |
dc.subject.other | Xâ ray detectors | |
dc.subject.other | Photons | |
dc.subject.other | Image detection systems | |
dc.subject.other | Medical Xâ ray imaging | |
dc.subject.other | Tungsten | |
dc.subject.other | Modulation transfer functions | |
dc.subject.other | Xâ ray optics | |
dc.subject.other | Monte Carlo methods | |
dc.subject.other | Radiography | |
dc.subject.other | Monte Carlo methods | |
dc.subject.other | Simulation | |
dc.subject.other | Verification | |
dc.subject.other | Scintillation detectors | |
dc.subject.other | radiation therapy | |
dc.subject.other | optical transfer function | |
dc.subject.other | flat panel displays | |
dc.subject.other | diagnostic radiography | |
dc.subject.other | solid scintillation detectors | |
dc.subject.other | segmented crystal detectors | |
dc.subject.other | quantum efficiency | |
dc.title | Segmented crystalline scintillators: An initial investigation of high quantum efficiency detectors for megavoltage xâ ray imaging | |
dc.type | Article | en_US |
dc.rights.robots | IndexNoFollow | |
dc.subject.hlbsecondlevel | Medicine (General) | |
dc.subject.hlbtoplevel | Health Sciences | |
dc.description.peerreviewed | Peer Reviewed | |
dc.contributor.affiliationum | Department of Radiation Oncology, University of Michigan, Ann Arbor, Michigan 48105 | |
dc.contributor.affiliationother | Radiation Monitoring Devices, Watertown, Massachusetts 02472 | |
dc.contributor.affiliationother | Imaging Research Laboratories, Robarts Research Institute, London, Ontario N6A 5C1, Canada | |
dc.description.bitstreamurl | http://deepblue.lib.umich.edu/bitstream/2027.42/134936/1/mp8407.pdf | |
dc.identifier.doi | 10.1118/1.2008407 | |
dc.identifier.source | Medical Physics | |
dc.identifier.citedreference | M. A. H. Chowdhury, S. J. Watts, D. C. Imrie, A. K. McKemey, and A. G. Holmesâ Siedle, â Studies of radiation tolerance and optical absorption bands of CsI(Tl) crystals,â Nucl. Instrum. Methods Phys. Res. A NIMAER --> 0168‐9002 --> 432, 147 â 156 ( 1999 ). | |
dc.identifier.citedreference | M. A. Moslehâ Shirazi, W. Swindell, and P. M. Evans, â Optimization of the scintillation detector in a combined 3D megavoltage CT scanner and portal imager,â Med. Phys. MPHYA6 --> 0094‐2405 --> 10.1118/1.598377 25, 1880 â 1890 ( 1998 ). | |
dc.identifier.citedreference | A. Badano and R. Leimbach, â Depthâ dependent phosphor blur in indirect xâ ray imaging sensors,â Proc. SPIE PSISDG --> 0277‐786X --> 4682, 94 â 106 ( 2002 ). | |
dc.identifier.citedreference | A. Badano et al., â Lubberts effect in columnar phosphors,â Med. Phys. MPHYA6 --> 0094‐2405 --> 10.1118/1.1796151 31, 3122 â 3131 ( 2004 ). | |
dc.identifier.citedreference | M. Albert and A. D. Maidment, â Linear response theory for detectors consisting of discrete arrays,â Med. Phys. MPHYA6 --> 0094‐2405 --> 10.1118/1.1286592 27, 2417 â 2434 ( 2000 ). | |
dc.identifier.citedreference | I. Cunningham, â Applied linearâ systems theory,â in Handbook of Medical Imaging, edited by J. Beutel, H. L. Kundel, and R. L. Van Metter ( SPIE Press, Bellingham, Washington, 2000 ), pp. 79 â 159. | |
dc.identifier.citedreference | M. L. Giger and K. Doi, â Investigation of basic imaging properties in digital radiography. I: Modulation transfer function,â Med. Phys. MPHYA6 --> 0094‐2405 --> 10.1118/1.595629 11, 287 â 295 ( 1984 ). | |
dc.identifier.citedreference | A. Papoulis, Probability, Randomâ Variables, and Stochasticâ Processes, 3rd ed. ( McGraw Hill, New York, 1991 ). | |
dc.identifier.citedreference | W. A. Gardner and L. E. Franks, â Characterization of cyclostationary random signal processes,â IEEE Trans. Inf. Theory IETTAW --> 0018‐9448 --> 10.1109/TIT.1975.1055338 IT21, 4 â 14 ( 1975 ). | |
dc.identifier.citedreference | I. A. Cunningham, M. Sattarivand, G. Hajdok, and J. Yao, â Can a Fourierâ based cascadedâ systems analysis describe noise in complex shiftâ variant spatially sampled detectors? â Proc. SPIE PSISDG --> 0277‐786X --> 5368, 79 â 88 ( 2004 ). | |
dc.identifier.citedreference | J. T. Dobbins, â Image quality metrics for digital systems,â in Handbook of Medical Imaging, edited by J. Beutel, H. L. Kundel, and R. L. Van Metter ( SPIE Press, Bellingham, Washington, 2000 ), pp. 163 â 222. | |
dc.identifier.citedreference | J. C. Dainty and R. Shaw, Image Scienceâ Principles, Analysis and Evaluation of Photographicâ Type Imaging Processes ( Academic Press, New York, 1974 ). | |
dc.identifier.citedreference | M. Rabbani, R. Shaw, and R. Van Metter, â Detective quantum efficiency of imaging systems with amplifying and scattering mechanisms,â J. Opt. Soc. Am. A JOAOD6 --> 0740‐3232 --> 4, 895 â 901 ( 1987 ). | |
dc.identifier.citedreference | I. A. Cunningham, M. S. Westmore, and A. Fenster, â A spatialâ frequency dependent quantum accounting diagram and detective quantum efficiency model of signal and noise propagation in cascaded imaging systems,â Med. Phys. MPHYA6 --> 0094‐2405 --> 10.1118/1.597401 21, 417 â 427 ( 1994 ). | |
dc.identifier.citedreference | A. R. Sawant et al., â Exploring new frontiers in xâ ray quantum limited portal imaging using active matrix flatâ panel imagers (AMFPIs) â , Proceedings of SPIE Conference on the Physics of Medical Imaging, Vol. 5030, pp. 478â 489 (2003). | |
dc.identifier.citedreference | R. Y. Zhu, D. A. Ma, and H. Newman, â Scintillating crystals in a radiation environment,â Nucl. Phys. B NUPBBO --> 0550‐3213 --> 547 â 556 ( 1995 ). | |
dc.identifier.citedreference | R. Y. Zhu, â Radiation damage in scintillating crystals,â Nucl. Instrum. Methods Phys. Res. A NIMAER --> 0168‐9002 --> 10.1016/S0168â 9002(98)00498â 7 413, 297 â 311 ( 1998 ). | |
dc.identifier.citedreference | S. K. Sahu et al., â Radiation hardness of undoped BGO crystals,â Nucl. Instrum. Methods Phys. Res. A NIMAER --> 0168‐9002 --> 388, 144 â 148 ( 1997 ). | |
dc.identifier.citedreference | R. Georgii et al., â Influence of radiation damage on BGO scintillation properties,â Nucl. Instrum. Methods Phys. Res. A NIMAER --> 0168‐9002 --> 413, 50 â 58 ( 1998 ). | |
dc.identifier.citedreference | K. C. Peng et al., â Lowâ dose radiation damage and recovery of undoped BGO crystals,â Nucl. Instrum. Methods Phys. Res. A NIMAER --> 0168‐9002 --> 452, 252 â 255 ( 2000 ). | |
dc.identifier.citedreference | P. Kozma and P. Kozma, â Radiation resistivity of BGO crystals due to lowâ energy gammaâ rays,â Nucl. Instrum. Methods Phys. Res. A NIMAER --> 0168‐9002 --> 501, 499 â 504 ( 2003 ). | |
dc.identifier.citedreference | M. A. H. Chowdhury, A. Holmesâ Siedle, A. K. McKemey, S. J. Watts, and D. C. Imrie, â Radiation effects in CsI(Tl) crystals from a controlled growth process,â Nucl. Instrum. Methods Phys. Res. A NIMAER --> 0168‐9002 --> 413, 471 â 474 ( 1998 ). | |
dc.identifier.citedreference | M. M. Hamada, F. E. Costa, S. Shimizu, and S. Kubota, â Radiation damage of CsI(Tl) scintillators: Blocking of energy transfer process of Vâ k centers to Tl + activators,â Nucl. Instrum. Methods Phys. Res. A NIMAER --> 0168‐9002 --> 486, 330 â 335 ( 2002 ). | |
dc.identifier.citedreference | K. Kazui et al., â Study of the radiation hardness of CsI(Tl) crystals for the BELLE detector,â Nucl. Instrum. Methods Phys. Res. A NIMAER --> 0168‐9002 --> 394, 46 â 56 ( 1997 ). | |
dc.identifier.citedreference | C. L. Woody, J. A. Kierstead, P. W. Levy, and S. Stoll, â Radiationâ damage in undoped CsI and CsI(Tl),â IEEE Trans. Nucl. Sci. IETNAE --> 0018‐9499 --> 10.1109/23.159659 39, 524 â 531 ( 1992 ). | |
dc.identifier.citedreference | I. Kawrakow and D. W. O. Rogers, â The EGSnrc code system: Monte Carlo simulation of electron and photon transport,â Technical Report PIRSâ 701, National Research Council of Canada, Ottawa, Canada 2000. | |
dc.identifier.citedreference | J. A. Treurniet, B. R. B. Walters, and D. W. O. Rogers, â BEAMnrc, DOSXYZnrc and BEAMDP GUI user’s manual,â NRC Report PIRS 0623(rev B) ( 2001 ). | |
dc.identifier.citedreference | D. Sheikhâ Bagheri, â Monte Carlo study of photon beams from medical linear accelerators: Optimization, benchmark and spectra,â Ph.D. thesis, Dept. of Physics, Carleton University, 1999. | |
dc.identifier.citedreference | H. Fujita et al., â A simple method for determining the modulation transferâ function in digital radiography,â IEEE Trans. Med. Imaging ITMID4 --> 0278‐0062 --> 10.1109/42.126908 11, 34 â 39 ( 1992 ). | |
dc.identifier.citedreference | J. H. Siewerdsen et al., â Signal, noise power spectrum, and detective quantum efficiency of indirectâ detection flatâ panel imagers for diagnostic radiology,â Med. Phys. MPHYA6 --> 0094‐2405 --> 10.1118/1.598243 25, 614 â 628 ( 1998 ). | |
dc.identifier.citedreference | L. E. Antonuk et al., â Empirical investigation of the signal performance of a highâ resolution, indirect detection, active matrix flatâ panel imager (AMFPI) for fluoroscopic and radiographic operation,â Med. Phys. MPHYA6 --> 0094‐2405 --> 10.1118/1.597918 24, 51 â 70 ( 1997 ). | |
dc.identifier.citedreference | M. Moszynski, M. Kapusta, M. Mayhugh, D. Wolski, and S. O. Flyckt, â Absolute light output of scintillators,â IEEE Trans. Nucl. Sci. IETNAE --> 0018‐9499 --> 10.1109/23.603803 44, 1052 â 1061 ( 1997 ). | |
dc.identifier.citedreference | D. A. Jaffray, J. J. Battista, A. Fenster, and P. Munro, â Monteâ Carlo studies of xâ rayâ energy absorption and quantumâ noise in megavoltage transmission radiography,â Med. Phys. MPHYA6 --> 0094‐2405 --> 10.1118/1.597593 22, 1077 â 1088 ( 1995 ). | |
dc.identifier.citedreference | R. K. Swank, â Absorption and noise in xâ ray phosphors,â J. Appl. Phys. JAPIAU --> 0021‐8979 --> 10.1063/1.1662918 44, 4199 â 4203 ( 1973 ). | |
dc.identifier.citedreference | J. A. Rowlands and J. Yorkston, â Flat panel detectors for digital radiography,â in Handbook of Medical Imaging, edited by J. Beutel, H. L. Kundel, and R. L. Van Metter ( SPIE Press, Bellingham, Washington, 2000 ), pp. 223 â 328. | |
dc.identifier.citedreference | C. Kirkby and R. Sloboda, â Comprehensive Monte Carlo calculation of the point spread function for a commercial aâ Si EPID,â Med. Phys. MPHYA6 --> 0094‐2405 --> 10.1118/1.1869072 32, 1115 â 1127 ( 2005 ). | |
dc.identifier.citedreference | T. R. Mackie et al., â Image guidance for precise conformal radiotherapy,â Int. J. Radiat. Oncol., Biol., Phys. IOBPD3 --> 0360‐3016 --> 10.1016/S0360â 3016(03)00090â 7 56, 89 â 105 ( 2003 ). | |
dc.identifier.citedreference | J. L. Barker et al., â Quantification of volumetric and geometric changes occuring during fractionated radiotherapy for headâ andâ neck cancer using an integrated CT/linear accelerator system,â Int. J. Radiat. Oncol., Biol., Phys. IOBPD3 --> 0360‐3016 --> 59, 960 â 970 ( 2004 ). | |
dc.identifier.citedreference | K. Kuriyama et al., â A new irradiation unit constructed of selfâ moving gantryâ CT and linac,â Int. J. Radiat. Oncol., Biol., Phys. IOBPD3 --> 0360‐3016 --> 10.1016/S0360â 3016(02)03987â 1 55, 428 â 435 ( 2003 ). | |
dc.identifier.citedreference | J. M. Balter et al., â Daily targeting of intrahepatic tumors for radiotherapy,â Int. J. Radiat. Oncol., Biol., Phys. IOBPD3 --> 0360‐3016 --> 10.1016/S0360â 3016(01)01815â 6 52, 266 â 271 ( 2002 ). | |
dc.identifier.citedreference | D. A. Jaffray, K. Chawla, C. Yu, and J. W. Wong, â Dualâ beam imaging for online verification of radiotherapy field placement,â Int. J. Radiat. Oncol., Biol., Phys. IOBPD3 --> 0360‐3016 --> 10.1016/0360â 3016(95)00271â 5 33, 1273 â 1280 ( 1995 ). | |
dc.identifier.citedreference | D. A. Jaffray, D. G. Drake, M. Moreau, A. A. Martinez, and J. W. Wong, â A radiographic and tomographic imaging system integrated into a medical linear accelerator for localization of bone and softâ tissue targets,â Int. J. Radiat. Oncol., Biol., Phys. IOBPD3 --> 0360‐3016 --> 10.1016/S0360â 3016(99)00118â 2 45, 773 â 789 ( 1999 ). | |
dc.identifier.citedreference | D. A. Jaffray, J. H. Siewerdsen, J. W. Wong, and A. A. Martinez, â Flatâ panel coneâ beam computed tomography for imageâ guided radiation therapy,â Int. J. Radiat. Oncol., Biol., Phys. IOBPD3 --> 0360‐3016 --> 10.1016/S0360â 3016(02)02884â 5 53, 1337 â 1349 ( 2002 ). | |
dc.identifier.citedreference | J. Lattanzi, S. McNeeley, A. Hanlon, T. E. Schultheiss, and G. E. Hanks, â Ultrasoundâ based stereotactic guidance of precision conformal external beam radiation therapy in clinically localized prostate cancer,â Urology URGYAZ --> 0090‐4295 --> 10.1016/S0090â 4295(99)00389â 1 55, 73 â 78 ( 2000 ). | |
dc.identifier.citedreference | K. M. Langen et al., â Evaluation of ultrasoundâ based prostate localization for imageâ guided radiotherapy,â Int. J. Radiat. Oncol., Biol., Phys. IOBPD3 --> 0360‐3016 --> 10.1016/S0360â 3016(03)00633â 3 57, 635 â 644 ( 2003 ). | |
dc.identifier.citedreference | S. L. Meeks et al., â Ultrasoundâ guided extracranial radiosurgery: Technique and application,â Int. J. Radiat. Oncol., Biol., Phys. IOBPD3 --> 0360‐3016 --> 55, 1092 â 1101 ( 2003 ). | |
dc.identifier.citedreference | R. G. Simpson, C. T. Chen, E. A. Grubbs, and W. Swindell, â A 4 - MV CT scanner for radiation therapy: The prototype system,â Med. Phys. MPHYA6 --> 0094‐2405 --> 10.1118/1.595102 9, 574 â 579 ( 1982 ). | |
dc.identifier.citedreference | W. Swindell, R. G. Simpson, J. R. Oleson, C. Chen, and E. A. Grubbs, â Computed tomography with a linear accelerator with radiotherapy applications,â Med. Phys. MPHYA6 --> 0094‐2405 --> 10.1118/1.595391 10, 416 â 420 ( 1983 ). | |
dc.identifier.citedreference | A. Brahme, â Design principles and clinical possibilities with a new generation of radiation therapy equipment,â Acta Oncol. ACTOEL --> 0284‐186X --> 26, 403 â 412 ( 1987 ). | |
dc.identifier.citedreference | D. J. Krus, W. P. Novak, and L. Perna, â Precision linear and twoâ dimensional scintillation crystal arrays for xâ ray and gammaâ ray imaging applications,â Proc. SPIE on Hard Xâ Ray, Gammaâ Ray, and Neutron Detector Physics, Vol. 3768 ( 1999 ), pp. 183 â 194. | |
dc.identifier.citedreference | A. Lempicki et al., â A new lutetiaâ based ceramic scintillator for xâ ray imaging,â Nucl. Instrum. Methods Phys. Res. A NIMAER --> 0168‐9002 --> 10.1016/S0168â 9002(02)00556â 9 488, 579 â 590 ( 2002 ). | |
dc.identifier.citedreference | V. V. Nagarkar et al., â A new Xâ ray scintillator for digital radiography,â IEEE Trans. Nucl. Sci. IETNAE --> 0018‐9499 --> 50, 297 â 300 ( 2003 ). | |
dc.identifier.citedreference | L. E. Antonuk, â Electronic portal imaging devices: A review and historical perspective of contemporary technologies and research,â Phys. Med. Biol. PHMBA7 --> 0031‐9155 --> 47, R31 â R65 ( 2002 ). | |
dc.identifier.citedreference | L. E. Antonuk et al., â Initial performance evaluation of an indirectâ detection, active matrix flatâ panel imager (AMFPI) prototype for megavoltage imaging,â Int. J. Radiat. Oncol., Biol., Phys. IOBPD3 --> 0360‐3016 --> 10.1016/S0360â 3016(98)00210â 7 42, 437 â 454 ( 1998 ). | |
dc.identifier.citedreference | J. J. Kruse et al., â Electronic and film portal images: A comparison of landmark visibility and review accuracy,â Int. J. Radiat. Oncol., Biol., Phys. IOBPD3 --> 0360‐3016 --> 10.1016/S0360â 3016(02)02955â 3 54, 584 â 591 ( 2002 ). | |
dc.identifier.citedreference | P. Munro and D. C. Bouius, â Xâ ray quantum limited portal imaging using amorphous silicon flatâ panel arrays,â Med. Phys. MPHYA6 --> 0094‐2405 --> 10.1118/1.598252 25, 689 â 702 ( 1998 ). | |
dc.identifier.citedreference | Y. Elâ Mohri, K.â W. Jee, L. E. Antonuk, M. Maolinbay, and Q. Zhao, â Determination of the detective quantum efficiency of a prototype, megavoltage indirect detection, active matrix flatâ panel imager,â Med. Phys. MPHYA6 --> 0094‐2405 --> 10.1118/1.1413516 28, 2538 â 2550 ( 2001 ). | |
dc.identifier.citedreference | J.â P. Bissonnette, I. A. Cunningham, and P. Munro, â Optimal phosphor thickness for portal imaging,â Med. Phys. MPHYA6 --> 0094‐2405 --> 10.1118/1.598002 24, 803 â 814 ( 1997 ). | |
dc.identifier.citedreference | F. Cremers et al., â Performance of electronic portal imaging devices (EPIDs) used in radiotherapy: Image quality and dose measurements,â Med. Phys. MPHYA6 --> 0094‐2405 --> 10.1118/1.1688212 31, 985 â 996 ( 2004 ). | |
dc.identifier.citedreference | E. Samei and M. J. Flynn, â An experimental comparison of detector performance for direct and indirect digital radiography systems,â Med. Phys. MPHYA6 --> 0094‐2405 --> 10.1118/1.1561285 30, 608 â 622 ( 2003 ). | |
dc.identifier.citedreference | E. Samei, M. J. Flynn, H. G. Chotas, and J. T. Dobbins, â DQE of direct and indirect digital radiographic systems,â Proc. SPIE PSISDG --> 0277‐786X --> 4320, 189 â 197 ( 2001 ). | |
dc.identifier.citedreference | P. R. Granfors and R. Aufrichtig, â Performance of a 41X41â cm2 amorphous silicon flat panel xâ ray detector for radiographic imaging applications,â Med. Phys. MPHYA6 --> 0094‐2405 --> 10.1118/1.599010 27, 1324 â 1331 ( 2000 ). | |
dc.identifier.citedreference | D. L. Lee et al., â Filtered gain calibration and its effect on frequencyâ dependent DQE and image quality in SEâ based general radiography and fullâ field mammographic digital imaging,â Proc. SPIE PSISDG --> 0277‐786X --> 4320, 121 â 126 ( 2001 ). | |
dc.identifier.citedreference | G. Pang and J. A. Rowlands, â Development of high quantum efficiency flat panel detectors for portal imaging: Intrinsic spatial resolution,â Med. Phys. MPHYA6 --> 0094‐2405 --> 10.1118/1.1507779 29, 2274 â 2285 ( 2002 ). | |
dc.identifier.citedreference | E. J. Seppi et al., â Megavoltage coneâ beam computed tomography using a highâ efficiency image receptor,â Int. J. Radiat. Oncol., Biol., Phys. IOBPD3 --> 0360‐3016 --> 10.1016/S0360â 3016(02)04155â X 55, 793 â 803 ( 2003 ). | |
dc.identifier.citedreference | G. Pang and J. A. Rowlands, â Development of high quantum efficiency, flat panel, thick detectors for megavoltage xâ ray imaging: A novel directâ conversion design and its feasibility,â Med. Phys. MPHYA6 --> 0094‐2405 --> 10.1118/1.1803771 31, 3004 â 3016 ( 2004 ). | |
dc.identifier.citedreference | F. DiBianca, S. Samant, J. Laughter, J. Rasmussen, and C. Rodriguez, â Use of a kinestatic charge detector for megavoltage portal imaging,â Proceedings of SPIE Conference on Physics of Medical Imaging, Vol. 3032 ( 1997 ), pp. 195 â 201. | |
dc.identifier.citedreference | C. Iacobaeus et al., â A novel portal imaging device for advanced radiation therapy,â IEEE Trans. Nucl. Sci. IETNAE --> 0018‐9499 --> 10.1109/23.958386 48, 1496 â 1502 ( 2001 ). | |
dc.identifier.citedreference | T. T. Monajemi, S. Steciw, B. G. Fallone, and S. Rathee, â Modeling scintillatorâ photodiodes as detectors for megavoltage CT,â Med. Phys. MPHYA6 --> 0094‐2405 --> 10.1118/1.1710733 31, 1225 â 1234 ( 2004 ). | |
dc.identifier.citedreference | M. A. Moslehâ Shirazi et al., â Rapid portal imaging with a highâ efficiency, large fieldâ ofâ view detector,â Med. Phys. MPHYA6 --> 0094‐2405 --> 10.1118/1.598443 25, 2333 â 2346 ( 1998 ). | |
dc.identifier.citedreference | J. Ostling et al., â Novel detector for portal imaging in radiation therapy,â Proceedings of SPIE Conference on Physics of Medical Imaging, Vol. 3977 ( 2000 ), pp. 84 â 95. | |
dc.identifier.citedreference | A. Sawant et al., â Theoretical analysis and experimental evaluation of a CsI(Tl) based electronic portal imaging system,â Med. Phys. MPHYA6 --> 0094‐2405 --> 10.1118/1.1477231 29, 1042 â 1053 ( 2002 ). | |
dc.identifier.citedreference | B. Wowk and S. Shalev, â Thick phosphor screens for onâ line portal imaging,â Med. Phys. MPHYA6 --> 0094‐2405 --> 10.1118/1.597209 21, 1269 â 1276 ( 1994 ). | |
dc.identifier.citedreference | B. Wowk, S. Shalev, and T. Radcliffe, â Grooved phosphor screens for online portal imaging,â Med. Phys. MPHYA6 --> 0094‐2405 --> 10.1118/1.597160 20, 1641 â 1651 ( 1993 ). | |
dc.identifier.citedreference | B. A. Groh, J. H. Siewerdsen, D. G. Drake, J. W. Wong, and D. A. Jaffray, â A performance comparison of flatâ panel imagerâ based MV and kV coneâ beam CT,â Med. Phys. MPHYA6 --> 0094‐2405 --> 10.1118/1.1477234 29, 967 â 975 ( 2002 ). | |
dc.identifier.citedreference | F. A. Ghelmansarai et al., â Soft tissue visualization using a highly efficient megavoltage cone beam CT imaging system,â Proc. SPIE PSISDG --> 0277‐786X --> 5745, 159 â 170 ( 2005 ). | |
dc.identifier.citedreference | H. Keller et al., â Monte Carlo study of a highly efficient gas ionization detector for megavoltage imaging and imageâ guided radiotherapy,â Med. Phys. MPHYA6 --> 0094‐2405 --> 10.1118/1.1445414 29, 165 â 175 ( 2002 ). | |
dc.identifier.citedreference | K. M. Langen and D. T. Jones, â Organ motion and its management,â Int. J. Radiat. Oncol., Biol., Phys. IOBPD3 --> 0360‐3016 --> 10.1016/S0360â 3016(01)01453â 5 50, 265 â 278 ( 2001 ). | |
dc.identifier.citedreference | A. Sawant et al., â Segmented phosphors: MEMSâ based high quantum efficiency detectors for megavoltage xâ ray imaging,â Med. Phys. MPHYA6 --> 0094‐2405 --> 10.1118/1.1854774 32, 553 â 565 ( 2005 ). | |
dc.owningcollname | Interdisciplinary and Peer-Reviewed |
Files in this item
Remediation of Harmful Language
The University of Michigan Library aims to describe library materials in a way that respects the people and communities who create, use, and are represented in our collections. Report harmful or offensive language in catalog records, finding aids, or elsewhere in our collections anonymously through our metadata feedback form. More information at Remediation of Harmful Language.
Accessibility
If you are unable to use this file in its current format, please select the Contact Us link and we can modify it to make it more accessible to you.