Show simple item record

Evaluation of ion‐implanted‐silicon detectors for use in intraoperative positron‐sensitive probes

dc.contributor.authorRaylman, Raymond R.
dc.contributor.authorWahl, Richard L.
dc.date.accessioned2017-01-06T20:48:25Z
dc.date.available2017-01-06T20:48:25Z
dc.date.issued1996-11
dc.identifier.citationRaylman, Raymond R.; Wahl, Richard L. (1996). "Evaluation of ion‐implanted‐silicon detectors for use in intraoperative positron‐sensitive probes." Medical Physics 23(11): 1889-1895.
dc.identifier.issn0094-2405
dc.identifier.issn2473-4209
dc.identifier.urihttps://hdl.handle.net/2027.42/134953
dc.publisherAmerican Association of Physicists in Medicine
dc.publisherWiley Periodicals, Inc.
dc.subject.otherRADIATION DETECTORS
dc.subject.otherSENSITIVITY
dc.subject.other87.53.06
dc.subject.otherScintillation detectors
dc.subject.otherPhotons
dc.subject.otherPositrons
dc.subject.otherCancer
dc.subject.otherSpatial resolution
dc.subject.otherPhysicists
dc.subject.otherRadiopharmaceuticals
dc.subject.other87.55.07
dc.subject.otherSpectroscopic and microscopic techniques in biophysics and medical physics
dc.subject.otherSolid‐state detectors
dc.subject.otherNUCLEAR MEDICINE
dc.subject.otherRADIOPHARMACEUTICALS
dc.subject.otherNEOPLASMS
dc.subject.otherION IMPLANTATION
dc.subject.otherSURGERY
dc.subject.otherSPATIAL RESOLUTION
dc.subject.otherSILICON
dc.titleEvaluation of ion‐implanted‐silicon detectors for use in intraoperative positron‐sensitive probes
dc.typeArticleen_US
dc.rights.robotsIndexNoFollow
dc.subject.hlbsecondlevelMedicine (General)
dc.subject.hlbtoplevelHealth Sciences
dc.description.peerreviewedPeer Reviewed
dc.contributor.affiliationumDepartment of Internal Medicine, Division of Nuclear Medicine, University of Michigan Medical Center, Ann Arbor, Michigan
dc.contributor.affiliationumDepartment of Internal Medicine, Division of Nuclear Medicine, and Department of Radiology, University of Michigan Medical Center, Ann Arbor, Michigan
dc.description.bitstreamurlhttp://deepblue.lib.umich.edu/bitstream/2027.42/134953/1/mp7751.pdf
dc.identifier.doi10.1118/1.597751
dc.identifier.sourceMedical Physics
dc.owningcollnameInterdisciplinary and Peer-Reviewed


Files in this item

Show simple item record

Remediation of Harmful Language

The University of Michigan Library aims to describe library materials in a way that respects the people and communities who create, use, and are represented in our collections. Report harmful or offensive language in catalog records, finding aids, or elsewhere in our collections anonymously through our metadata feedback form. More information at Remediation of Harmful Language.

Accessibility

If you are unable to use this file in its current format, please select the Contact Us link and we can modify it to make it more accessible to you.