Show simple item record

A threeâ dimensional deformable model for segmentation of human prostate from ultrasound images

dc.contributor.authorGhanei, Amir
dc.contributor.authorSoltanian‐zadeh, Hamid
dc.contributor.authorRatkewicz, Alexander
dc.contributor.authorYin, Fang‐fang
dc.date.accessioned2017-01-06T20:48:56Z
dc.date.available2017-01-06T20:48:56Z
dc.date.issued2001-10
dc.identifier.citationGhanei, Amir; Soltanian‐zadeh, Hamid ; Ratkewicz, Alexander; Yin, Fang‐fang (2001). "A threeâ dimensional deformable model for segmentation of human prostate from ultrasound images." Medical Physics 28(10): 2147-2153.
dc.identifier.issn0094-2405
dc.identifier.issn2473-4209
dc.identifier.urihttps://hdl.handle.net/2027.42/134985
dc.publisherAmerican Association of Physicists in Medicine
dc.publisherWiley Periodicals, Inc.
dc.subject.otherMedical image contrast
dc.subject.othersegmentation
dc.subject.otherdeformable model
dc.subject.otherprostate
dc.subject.otherultrasound
dc.subject.otherradiation therapy
dc.subject.otherUltrasonography
dc.subject.otherMedical diagnosis with acoustics
dc.subject.otherGeneral theory and mathematical aspects
dc.subject.otherImage analysis
dc.subject.otherimage segmentation
dc.subject.otherbiological organs
dc.subject.otherbiomedical ultrasonics
dc.subject.othermedical image processing
dc.subject.othermodelling
dc.subject.otherUltrasonography
dc.subject.otherMedical imaging
dc.subject.otherMedical image segmentation
dc.subject.otherDosimetry
dc.subject.otherMultiscale methods
dc.subject.otherImage guided radiation therapy
dc.subject.otherPhysicists
dc.subject.otherMedical image noise
dc.subject.otherRadiation therapy
dc.titleA threeâ dimensional deformable model for segmentation of human prostate from ultrasound images
dc.typeArticleen_US
dc.rights.robotsIndexNoFollow
dc.subject.hlbsecondlevelMedicine (General)
dc.subject.hlbtoplevelHealth Sciences
dc.description.peerreviewedPeer Reviewed
dc.contributor.affiliationumUniversity of Michigan, Ann Arbor, Michigan 48105
dc.contributor.affiliationotherUniversity of Tehran, Tehran, 14399, Iran
dc.contributor.affiliationotherDepartment of Radiation Oncology, Henry Ford Health System, Detroit, Michigan 48202
dc.contributor.affiliationotherDepartment of Radiology, Henry Ford Health System, Detroit, Michigan 48202
dc.contributor.affiliationotherDepartment of Radiology, Henry Ford Health System, Detroit, Michigan 48202
dc.description.bitstreamurlhttp://deepblue.lib.umich.edu/bitstream/2027.42/134985/1/mp8221.pdf
dc.identifier.doi10.1118/1.1388221
dc.identifier.sourceMedical Physics
dc.identifier.citedreferenceR. Rao and J. Benâ Arie, â Optimal edge detection using expansion matching and restoration,â IEEE Trans. Pattern Anal. Mach. Intell. ITPIDJ --> 16, 1169 â 1182 ( 1994 ). ITPIDJ --> 0162â 8828
dc.identifier.citedreferenceP. H. Todd and R. J. Y. McLeod, â Numerical estimation of the curvature of the surfaces,â Comput. Aided Design CAIDA5 --> 18, 33 â 37 ( 1985 ). CAIDA5 --> 0010â 4485
dc.identifier.citedreferenceA. Ghanei, H. Soltanianâ Zadeh, and J. P. Windham, â A 3D deformable surface model for segmentation of objects from volumetric data in medical images,â Comput. Biol. Med. CBMDAW --> 28, 239 â 253 ( 1998 ). CBMDAW --> 0010â 4825
dc.identifier.citedreferenceS. D. Pathak, V. Chalana, D. R. Haynor, and Y. Kim, â Edge guided delineation of the prostate in transrectal ultrasound images,â Proceedings of the First Joint BMES/EMBS IEEE Conference, 1999, Vol. 2, 1056 pp.
dc.identifier.citedreferenceH. M. Ladak, D. B. Downey, D. A. Steinman, and A. Fenster, â Semiâ automatic technique for segmentation of the prostate from 2D ultrasound images,â Proceedings of the First Joint BMES/EMBS Conference 1999 IEEE, Engineering in Medicine and Biology 21st Annual Conference, Vol. 2, 1144 pp.
dc.identifier.citedreferenceC. Knoll, V. Grau, M. Alcaniz, S. Albalat, C. Montserrat, H. U. Lemke, K. Inamura, and M. W. Vannier, â A new conformal radiotherapy planning system for prostate carcinoma,â Proceedings of Computer Assisted Radiology and Surgery, CAR 97, 25â 28 June 1997, Berlin, Germany, 1997, pp. 375â 380.
dc.identifier.citedreferenceC. Knoll, M. Alcaniz, V. Grau, C. Montserrat, and M. C. Juan, â Outlining of the prostate using snakes with shape restrictions based on the wavelet transform,â Pattern Recogn. PTNRA8 --> 32, 1767 â 1781 ( 1999 ). PTNRA8 --> 0031â 3203
dc.identifier.citedreferenceC. Knoll, M. Alcaniz, C. Monserrat, V. Grau, and M. C. Juan, â Multiresolution segmentation of medical images using shapeâ restricted snakes,â Proc. SPIE PSISDG --> 32, 1767 â 1781 ( 1999 ). PSISDG --> 0277â 786X
dc.identifier.citedreferenceC. H. Chen, J. Y. Lee, W. H. Yang, C. M. Chang, and Y. N. Sun, â Segmentation and reconstruction of prostate from transrectal ultrasound images,â Biomed. Eng. Appl. Basisâ Commun. YIGOEO --> 8, 287 â 292 ( 1996 ). YIGOEO --> 1016â 2356
dc.identifier.citedreferenceC. H. Chen, J. D. Lee, and H. B. Hsieh, â 3D reconstruction of the prostate from transrectal ultrasound images,â Biomed. Eng. Appl. Basis Commun. YIGOEO --> 11, 1 â 10 ( 1999 ). YIGOEO --> 1016â 2356
dc.identifier.citedreferenceW. D. Richard and C. G. Keen, â Automated textureâ based segmentation of ultrasound images of the prostate,â Comput. Medical Imag. Graphics CMIGEY --> 20, 131 â 140 ( 1996 ). CMIGEY --> 0895â 6111
dc.identifier.citedreferenceJ. S. Prater and W. D. Richard, â Segmenting ultrasound images of the prostrate using neural networks,â Ultrason. Imaging ULIMD4 --> 14, 159 â 185 ( 1992 ). ULIMD4 --> 0161â 7346
dc.identifier.citedreferenceK. H. Englmeier, R. Hecker, and S. J. Poppl, â A computer assisted estimate of the volume of the prostate gland obtained from transrectal ultrasonic tomograms,â Proceedings of the fifth DAGM Symposium on Pattern Recognition, October 1983, Karlsruhe, Germany, 1983, Vol. 35, pp. 361â 366.
dc.identifier.citedreferenceA. Ghanei, H. Soltanianâ Zadeh, and J. P. Windham, â Segmentation of hippocampus from brain MRI using deformable contours,â Comput. Med. Imaging Graphics CMIGEY --> 22, 203 â 216 ( 1998 ). CMIGEY --> 0895â 6111
dc.identifier.citedreferenceN. R. Czerwinski, L. D. Jones, and D. W. O’Brien, â Edge detection in ultrasound speckle noise,â IEEE Int. Conf. Image Process. 3, 304 â 308 ( 1994 ).
dc.owningcollnameInterdisciplinary and Peer-Reviewed


Files in this item

Show simple item record

Remediation of Harmful Language

The University of Michigan Library aims to describe library materials in a way that respects the people and communities who create, use, and are represented in our collections. Report harmful or offensive language in catalog records, finding aids, or elsewhere in our collections anonymously through our metadata feedback form. More information at Remediation of Harmful Language.