Show simple item record

Distance‐preserving rigidity penalty on deformable image registration of multiple skeletal components in the neck

dc.contributor.authorKim, Jihun
dc.contributor.authorMatuszak, Martha M.
dc.contributor.authorSaitou, Kazuhiro
dc.contributor.authorBalter, James M.
dc.date.accessioned2017-01-06T20:48:58Z
dc.date.available2017-01-06T20:48:58Z
dc.date.issued2013-12
dc.identifier.citationKim, Jihun; Matuszak, Martha M.; Saitou, Kazuhiro; Balter, James M. (2013). "Distance‐preserving rigidity penalty on deformable image registration of multiple skeletal components in the neck." Medical Physics 40(12): n/a-n/a.
dc.identifier.issn0094-2405
dc.identifier.issn2473-4209
dc.identifier.urihttps://hdl.handle.net/2027.42/134988
dc.publisherAmerican Association of Physicists in Medicine
dc.publisherWiley Periodicals, Inc.
dc.subject.othercervical vertebra
dc.subject.otherComputed tomography
dc.subject.otherRegistration
dc.subject.otherInterpolation; curve fitting
dc.subject.otherbone
dc.subject.othercomputerised tomography
dc.subject.otherimage registration
dc.subject.othermedical image processing
dc.subject.otherradiation therapy
dc.subject.othersplines (mathematics)
dc.subject.otherstatistical analysis
dc.subject.otherrigidity penalty
dc.subject.otherdeformable image registration
dc.subject.otherhead and neck
dc.subject.otherComputerised tomographs
dc.subject.otherBiological material, e.g. blood, urine; Haemocytometers
dc.subject.otherDigital computing or data processing equipment or methods, specially adapted for specific applications
dc.subject.otherImage data processing or generation, in general
dc.subject.otherMedical imaging
dc.subject.otherImage registration
dc.subject.otherComputed tomography
dc.subject.otherCone beam computed tomography
dc.subject.otherDosimetry
dc.subject.otherTensor methods
dc.subject.otherCancer
dc.subject.otherSurface measurements
dc.subject.otherTissues
dc.subject.otherRadiation therapy
dc.titleDistance‐preserving rigidity penalty on deformable image registration of multiple skeletal components in the neck
dc.typeArticleen_US
dc.rights.robotsIndexNoFollow
dc.subject.hlbsecondlevelMedicine (General)
dc.subject.hlbtoplevelHealth Sciences
dc.description.peerreviewedPeer Reviewed
dc.contributor.affiliationumDepartment of Mechanical Engineering, University of Michigan, Ann Arbor, Michigan 48109
dc.contributor.affiliationumDepartment of Radiation Oncology, University of Michigan, Ann Arbor, Michigan 48109
dc.contributor.affiliationumDepartment of Mechanical Engineering, University of Michigan, Ann Arbor, Michigan 48109
dc.contributor.affiliationumDepartment of Radiation Oncology, University of Michigan, Ann Arbor, Michigan 48109
dc.description.bitstreamurlhttp://deepblue.lib.umich.edu/bitstream/2027.42/134988/1/mp8783.pdf
dc.identifier.doi10.1118/1.4828783
dc.identifier.sourceMedical Physics
dc.identifier.citedreferenceP. H. Schönemann, “ A generalized solution of the orthogonal Procrustes problem,” Psychometrika 31, 1 – 10 ( 1966 ). 10.1007/BF02289451
dc.identifier.citedreferenceD. Mattes, D. R. Haynor, H. Vesselle, T. Lewellen, and W. Eubank, “ Nonrigid multimodality image registration,” Proc. SPIE 4322, 1609 – 1620 ( 2001 ). 10.1117/12.431046
dc.identifier.citedreferenceD. Mattes, D. R. Haynor, H. Vesselle, T. Lewellen, and W. Eubank, “ PET‐CT image registration in the chest using free‐form deformations,” IEEE Trans. Med. Imaging 22, 120 – 128 ( 2003 ). 10.1109/TMI.2003.809072
dc.identifier.citedreferenceM. Unser, A. Aldroubi, and M. Eden, “ B‐spline signal processing: Part I‐Theory,” IEEE Trans. Signal Process. 41, 821 – 833 ( 1993 ). 10.1109/78.193220
dc.identifier.citedreferenceS. Klein, M. Staring, K. Murphy, M. A. Viergever, and J. P. W. Pluim, “ Elastix: A toolbox for intensity based medical image registration,” IEEE Trans. Med. Imaging 29, 196 – 205 ( 2010 ). 10.1109/TMI.2009.2035616
dc.identifier.citedreferenceJ. C. Spall, “ Implementation of the simultaneous perturbation algorithm of stochastic optimization,” IEEE Trans. Aerosp. Electron. Syst. 34, 817 – 823 ( 1998 ). 10.1109/7.705889
dc.identifier.citedreferenceP. H. Ahn, A. I. Ahn, C. J. Lee, J. Shen, E. Miller, A. Lukaj, E. Milan, R. Yaparpalvi, S. Kalnicki, and M. K. Garg, “ Random positional variation among the skull, mandible, and cervical spine with treatment progression during head‐and‐neck radiotherapy,” Int. J. Radiat. Oncol., Biol., Phys. 73, 626 – 633 ( 2009 ). 10.1016/j.ijrobp.2008.10.007
dc.identifier.citedreferenceG. A. Holzapfel, Nonlinear Solid Mechanics: A Continuum Approach for Engineering ( Wiley, New York, 2000 ).
dc.identifier.citedreferenceL. Xing, Q. Wu, Y. Yang, and A. Boyer, “ Physics of IMRT,” in Intensity Modulated Radiation Therapy: A Clinical Perspective, edited by A. J. Mundt and J. C. Roeske ( B. C. Decker, Inc., Hamilton, 2005 ), pp. 20 – 52.
dc.identifier.citedreferenceH. Wang, A. S. Garden, L. Zhang, X. Wei, A. Ahamad, D. A. Kuban, R. Komaki, J. O’Daniel, Y. Zhang, R. Mohan, and L. Dong, “ Performance evaluation of automatic anatomy segmentation algorithm on repeat or four‐dimensional computed tomography images using deformable image registration method,” Int. J. Radiat. Oncol., Biol., Phys. 72, 210 – 219 ( 2008 ). 10.1016/j.ijrobp.2008.05.008
dc.identifier.citedreferenceT. Zhang, Y. Chi, E. Meldolesi, and D. Yan, “ Automatic delineation of on‐line head‐and‐neck computed tomography images: Toward on‐line adaptive radiotherapy,” Int. J. Radiat. Oncol., Biol., Phys. 68, 522 – 530 ( 2007 ). 10.1016/j.ijrobp.2007.01.038
dc.identifier.citedreferenceC. Lee, K. M. Langen, W. Lu, J. Haimerl, E. Schnarr, K. J. Ruchala, G. H. Olivera, S. L. Meeks, P. A. Kupelian, T. D. Shellenberger, and R. R. Manñ on, “ Evaluation of geometric changes of parotid glands during head and neck cancer radiotherapy using daily MVCT and automatic deformable registration,” Radiother. Oncol. 89, 81 – 88 ( 2008 ). 10.1016/j.radonc.2008.07.006
dc.identifier.citedreferenceC. Lee, K. M. Langen, W. Lu, J. Haimerl, E. Schnarr, K. J. Ruchala, G. H. Olivera, S. L. Meeks, P. A. Kupelian, T. D. Shellenberger, and R. R. Mañon, “ Assessment of parotid gland dose changes during head and neck cancer radiotherapy using daily megavoltage computed tomography and deformable image registration,” Int. J. Radiat. Oncol., Biol., Phys. 71, 1563 – 1571 ( 2008 ). 10.1016/j.ijrobp.2008.04.013
dc.identifier.citedreferenceQ. Wu, Y. Chi, P. Y. Chen, D. J. Krauss, D. Yan, and A. Martinez, “ Adaptive replanning strategies accounting for shrinkage in head and neck IMRT,” Int. J. Radiat. Oncol., Biol., Phys. 75, 924 – 932 ( 2009 ). 10.1016/j.ijrobp.2009.04.047
dc.identifier.citedreferenceM. Peroni, D. Ciardo, M. F. Spadea, M. Riboldi, S. Comi, D. Alterio, G. Baroni, and R. Orecchia, “ Automatic segmentation and online virtual CT in head‐and‐neck adaptive radiation therapy,” Int. J. Radiat. Oncol., Biol., Phys. 84, e427 – e433 ( 2012 ). 10.1016/j.ijrobp.2012.04.003
dc.identifier.citedreferenceT. Rohlfing, “ Image similarity and tissue overlaps as surrogates for image registration accuracy: Widely used but unreliable,” IEEE Trans. Med. Imaging 31, 153 – 163 ( 2012 ). 10.1109/TMI.2011.2163944
dc.identifier.citedreferenceN. Kirby, C. Chuang, and J. Pouliot, “ A two‐dimensional deformable phantom for quantitatively verifying deformation algorithms,” Med. Phys. 38, 4583 – 4586 ( 2011 ). 10.1118/1.3597881
dc.identifier.citedreferenceS. Nithiananthan, S. Schafer, A. Uneri, D. J. Mirota, J. W. Stayman, W. Zbijewski, K. K. Brock, M. J. Daly, H. Chan, J. C. Irish, and J. H. Siewerdsen, “ Demons deformable registration of CT and cone‐beam CT using an iterative intensity matching approach,” Med. Phys. 38, 1785 – 1798 ( 2011 ). 10.1118/1.3555037
dc.identifier.citedreferenceX. Han, M. S. Hoogeman, P. C. Levendag, L. S. Hibbard, D. N. Teguh, P. Voet, A. C. Cowen, and T. K. Wolf, “ Atlas‐based auto‐segmentation of head and neck CT images,” in MICCAI, Lecture Notes in Computer Science Vol. 5242 ( Springer‐Verlag, Berlin, 2008 ), pp. 434 – 441.
dc.identifier.citedreferenceC. O. S. Sorzano, P. Thévenaz, and M. Unser, “ Elastic registration of biological images using vector‐spline regularization,” IEEE Trans. Biomed. Eng. 52, 652 – 663 ( 2005 ). 10.1109/TBME.2005.844030
dc.identifier.citedreferenceM. Sdika, “ A fast nonrigid image registration with constraints on the Jacobian using large scale constrained optimization,” IEEE Trans. Med. Imaging 27, 271 – 281 ( 2008 ). 10.1109/TMI.2007.905820
dc.identifier.citedreferenceT. Rohlfing, C. R. Maurer, D. A. Bluemke, and M. A. Jacobs, “ Volume‐preserving nonrigid registration of MR breast images using free‐form deformation with an incompressibility constraint,” IEEE Trans. Med. Imaging 22, 730 – 741 ( 2003 ). 10.1109/TMI.2003.814791
dc.identifier.citedreferenceD. Loeckx, F. Maes, D. Vandermeulen, and P. Suetens, “ Nonrigid image registration using free‐form deformations with a local rigidity constraint,” in MICCAI, Lecture Notes in Computer Science Vol. 3216 ( Springer‐Verlag, Berlin, 2004 ), pp. 639 – 646.
dc.identifier.citedreferenceD. Ruan, J. A. Fessler, M. Roberson, J. Balter, and M. Kessler, “ Nonrigid registration using regularization that accommodates local tissue rigidity,” Proc. SPIE 6144, 346 – 354 ( 2006 ). 10.1117/12.653870
dc.identifier.citedreferenceM. Staring, S. Klein, and J. P. W. Pluim, “ A rigidity penalty term for nonrigid registration,” Med. Phys. 34, 4098 – 4108 ( 2007 ). 10.1118/1.2776236
dc.owningcollnameInterdisciplinary and Peer-Reviewed


Files in this item

Show simple item record

Remediation of Harmful Language

The University of Michigan Library aims to describe library materials in a way that respects the people and communities who create, use, and are represented in our collections. Report harmful or offensive language in catalog records, finding aids, or elsewhere in our collections anonymously through our metadata feedback form. More information at Remediation of Harmful Language.

Accessibility

If you are unable to use this file in its current format, please select the Contact Us link and we can modify it to make it more accessible to you.