Technical note: A physical phantom for assessment of accuracy of deformable alignment algorithms
dc.contributor.author | Kashani, Rojano | |
dc.contributor.author | Hub, Martina | |
dc.contributor.author | Kessler, Marc L. | |
dc.contributor.author | Balter, James M. | |
dc.date.accessioned | 2017-01-06T20:49:32Z | |
dc.date.available | 2017-01-06T20:49:32Z | |
dc.date.issued | 2007-07 | |
dc.identifier.citation | Kashani, Rojano; Hub, Martina; Kessler, Marc L.; Balter, James M. (2007). "Technical note: A physical phantom for assessment of accuracy of deformable alignment algorithms." Medical Physics 34(7): 2785-2788. | |
dc.identifier.issn | 0094-2405 | |
dc.identifier.issn | 2473-4209 | |
dc.identifier.uri | https://hdl.handle.net/2027.42/135023 | |
dc.publisher | Wiley Periodicals, Inc. | |
dc.publisher | American Association of Physicists in Medicine | |
dc.subject.other | Radiation treatment | |
dc.subject.other | Radiography | |
dc.subject.other | Image analysis | |
dc.subject.other | Hemodynamics | |
dc.subject.other | Pneumodyamics, respiration | |
dc.subject.other | Image processing | |
dc.subject.other | image registration | |
dc.subject.other | diagnostic radiography | |
dc.subject.other | phantoms | |
dc.subject.other | medical image processing | |
dc.subject.other | quality assurance | |
dc.subject.other | lung | |
dc.subject.other | pneumodynamics | |
dc.subject.other | deformable alignment | |
dc.subject.other | IGRT | |
dc.subject.other | image registration | |
dc.subject.other | Image registration | |
dc.subject.other | Medical imaging | |
dc.subject.other | Foams | |
dc.subject.other | Plasticity | |
dc.subject.other | Medical image artifacts | |
dc.subject.other | Error analysis | |
dc.subject.other | Bifurcations | |
dc.subject.other | Testing procedures | |
dc.subject.other | Radiation therapy | |
dc.title | Technical note: A physical phantom for assessment of accuracy of deformable alignment algorithms | |
dc.type | Article | en_US |
dc.rights.robots | IndexNoFollow | |
dc.subject.hlbsecondlevel | Medicine (General) | |
dc.subject.hlbtoplevel | Health Sciences | |
dc.description.peerreviewed | Peer Reviewed | |
dc.contributor.affiliationum | Department of Radiation Oncology, University of Michigan, Ann Arbor, Michigan 48109 | |
dc.description.bitstreamurl | http://deepblue.lib.umich.edu/bitstream/2027.42/135023/1/mp9812.pdf | |
dc.identifier.doi | 10.1118/1.2739812 | |
dc.identifier.source | Medical Physics | |
dc.identifier.citedreference | D. W. Litzenberg, S. W. Hadley, N. Tyagi, J. M. Balter, R. K. Ten Haken, and I. J. Chetty, “ Synchronized dynamic dose reconstruction,” Med. Phys. MPHYA6 --> 0094‐2405 --> 10.1118/1.2388157 34, 91 – 102 ( 2007 ). | |
dc.identifier.citedreference | R. Kashani, K. Lam, D. W. Litzenberg, and J. M. Balter, “ Technical note: A deformable phantom for dynamic modeling in radiation therapy,” Med. Phys. MPHYA6 --> 0094‐2405 --> 10.1118/1.2400612 34, 199 – 201 ( 2007 ). | |
dc.identifier.citedreference | V. Walimbe and R. Shekhar, “ Automatic elastic image registration by interpolation of 3D rotations and translations from discrete rigid‐body transformations,” Med. Image Anal 1361‐8415 --> 10, 899 – 914 ( 2006 ). | |
dc.identifier.citedreference | J. M. Fitzpatrick, D. L. G. Hill, Y. Shyr, J. West, C. Studholme, and C. R. Maurer, “ Visual assessment of the accuracy of retrospective registration of MR and CT images of the brain,” IEEE Trans. Med. Imaging ITMID4 --> 0278‐0062 --> 10.1109/42.730402 17, 571 – 585 ( 1998 ). | |
dc.identifier.citedreference | J. R. McClelland, J. M. Blackall, S. Tarte, A. C. Chandler, S. Hughes, S. Ahmad, D. Landau, and D. Hawkes, “ A continuous 4D motion model from multiple respiratory cycles for use in lung radiotherapy,” Med. Phys. MPHYA6 --> 0094‐2405 --> 10.1118/1.2222079 33, 3348 – 3358 ( 2006 ). | |
dc.identifier.citedreference | K. K. Brock, M. B. Sharp, L. A. Dawson, S. M. Kim, and D. A. Jaffray, “ Accuracy of finite element model‐based multi‐organ deformable image registration,” Med. Phys. MPHYA6 --> 0094‐2405 --> 10.1118/1.1915012 32, 1647 – 1659 ( 2005 ). | |
dc.identifier.citedreference | M. M. Coselmon, J. M. Balter, D. L. McShan, and M. L. Kessler, “ Mutual information based CT registration of the lung at exhale and inhale breathing states using thin‐plate splines,” Med. Phys. MPHYA6 --> 0094‐2405 --> 10.1118/1.1803671 31, 2942 – 2948 ( 2004 ). | |
dc.identifier.citedreference | E. Rietzel and G. T. Y. Chen, “ Deformable registration of 4D computed tomography data,” Med. Phys. MPHYA6 --> 0094‐2405 --> 10.1118/1.2361077 33, 4423 – 4430 ( 2006 ). | |
dc.identifier.citedreference | J. P. Voroney, K. K. Brock, C. Eccles, M. Haider, and L. A. Dawson, “ Prospective comparison of computed tomography and magnetic resonance imaging for liver cancer delineation using deformable image registration,” Int. J. Radiat. Oncol., Biol., Phys. IOBPD3 --> 0360‐3016 --> 66, 780 – 791 ( 2006 ). | |
dc.identifier.citedreference | J. A. Schnabel, C. Tanner, A. D. Castellano‐Smith, A. Degenhard, M. O. Leach, D. R. Hose, and D. L. G. Hill, “ Validation of nonrigid image registration using finite‐element methods: Application to breast MR images.” IEEE Trans. Med. Imaging ITMID4 --> 0278‐0062 --> 10.1109/TMI.2002.808367 22, 238 – 247 ( 2003 ). | |
dc.identifier.citedreference | Y. Y. Chou and O. Skrinjar, “ Ground truth data for validation of nonrigid image registration algorithms,” IEEE Int. Symp. Biomed. Imag. Macro to Nano 1, 716 – 719 ( 2004 ). | |
dc.identifier.citedreference | T. Guerrero, G. Zhang, T. Huang, and K. Lin, “ Intrathoracic tumor motion estimation from CT imaging using the 3D optical flow method,” Phys. Med. Biol. PHMBA7 --> 0031‐9155 --> 10.1088/0031‐9155/49/17/022 49, 4147 – 4161 ( 2004 ). | |
dc.identifier.citedreference | H. Wang, L. Dong, J. O’Daniel, R. Mohan, A. S. Garden, K. K. Ang, D. A. Kuban, M. Bonnen, J. Y. Chang, and R. Cheung, “ Validation of an accelerated `demons’ algorithm for deformable image registration in radiation therapy,” Phys. Med. Biol. PHMBA7 --> 0031‐9155 --> 10.1088/0031‐9155/50/12/011 50, 2887 – 2905 ( 2005 ). | |
dc.identifier.citedreference | H. Wang, L. Dong, M. F. Lii, R. de Crevoisier, R. Mohan, J. D. Cox, D. A. Kuban, and R. Cheung, “ Implementation and validation of a three‐dimensional deformable registration algorithm for targeted prostate cancer radiotherapy,” Int. J. Radiat. Oncol., Biol., Phys. IOBPD3 --> 0360‐3016 --> 10.1016/j.ijrobp.2004.07.677 61, 725 – 735 ( 2005 ). | |
dc.identifier.citedreference | M. L. Kessler, “ Image registration and data fusion in radiation therapy,” Br. J. Radiol. BJRAAP --> 0007‐1285 --> 79, S99 – S108 ( 2006 ). | |
dc.identifier.citedreference | W. Y. Song, E. Wong, G. S. Bauman, J. J. Battista, and J. Van Dyke, “ Dosimetric evaluation of daily rigid and nonrigid geometric correction strategies during on‐line image‐guided radiation therapy (IGRT) of prostate cancer,” Med. Phys. MPHYA6 --> 0094‐2405 --> 10.1118/1.2405325 34, 352 – 365 ( 2007 ). | |
dc.identifier.citedreference | E. K. Hansen, M. K. Bucci, J. M. Quivey, V. Weinberg, and P. Xia, “ Repeat CT imaging and replanning during the course of IMRT for head‐and‐neck cancer,” Int. J. Radiat. Oncol., Biol., Phys. IOBPD3 --> 0360‐3016 --> 10.1016/j.ijrobp.2005.07.957 64, 355 – 362 ( 2006 ). | |
dc.identifier.citedreference | R. Mohan, X. Zhang, H. Wang, Y. Kang, X. Wang, H. Liu, K. K. Ang, D. Kuban, and L. Dong, “ Use of deformed intensity distributions for on‐line modification of image‐guided IMRT to account for interfractional anatomic changes,” Int. J. Radiat. Oncol., Biol., Phys. IOBPD3 --> 0360‐3016 --> 10.1016/j.ijrobp.2004.11.033 61, 1258 – 1266 ( 2005 ). | |
dc.identifier.citedreference | U. Malsch, C. Thieke, P. E. Huber, and R. Bendl, “ An enhanced block matching algorithm for fast elastic registration in adaptive radiotherapy,” Phys. Med. Biol. PHMBA7 --> 0031‐9155 --> 10.1088/0031‐9155/51/19/005 51, 4789 – 4806 ( 2006 ). | |
dc.owningcollname | Interdisciplinary and Peer-Reviewed |
Files in this item
Remediation of Harmful Language
The University of Michigan Library aims to describe library materials in a way that respects the people and communities who create, use, and are represented in our collections. Report harmful or offensive language in catalog records, finding aids, or elsewhere in our collections anonymously through our metadata feedback form. More information at Remediation of Harmful Language.
Accessibility
If you are unable to use this file in its current format, please select the Contact Us link and we can modify it to make it more accessible to you.