Show simple item record

Lung nodule detection on thoracic computed tomography images: Preliminary evaluation of a computerâ aided diagnosis system

dc.contributor.authorGurcan, Metin N.
dc.contributor.authorSahiner, Berkman
dc.contributor.authorPetrick, Nicholas
dc.contributor.authorChan, Heang‐ping
dc.contributor.authorKazerooni, Ella A.
dc.contributor.authorCascade, Philip N.
dc.contributor.authorHadjiiski, Lubomir
dc.date.accessioned2017-01-06T20:49:49Z
dc.date.available2017-01-06T20:49:49Z
dc.date.issued2002-11
dc.identifier.citationGurcan, Metin N.; Sahiner, Berkman; Petrick, Nicholas; Chan, Heang‐ping ; Kazerooni, Ella A.; Cascade, Philip N.; Hadjiiski, Lubomir (2002). "Lung nodule detection on thoracic computed tomography images: Preliminary evaluation of a computerâ aided diagnosis system." Medical Physics 29(11): 2552-2558.
dc.identifier.issn0094-2405
dc.identifier.issn2473-4209
dc.identifier.urihttps://hdl.handle.net/2027.42/135039
dc.publisherAmerican Association of Physicists in Medicine
dc.publisherWiley Periodicals, Inc.
dc.subject.othercomputerâ aided diagnosis
dc.subject.othercomputed tomography
dc.subject.otherlung nodule
dc.subject.otherPhysicists
dc.subject.otherCluster analysis
dc.subject.otherMedical imaging
dc.subject.otherLaser Doppler velocimetry
dc.subject.otherComputer aided diagnosis
dc.subject.otherImage detection systems
dc.subject.otherComputed tomography
dc.subject.otherLungs
dc.subject.otherfeature extraction
dc.subject.othermedical expert systems
dc.subject.otherblood vessels
dc.subject.otherimage classification
dc.subject.otherimage segmentation
dc.subject.othermedical image processing
dc.subject.othercomputerised tomography
dc.subject.otherlung
dc.subject.otherPattern recognition
dc.subject.otherImage analysis
dc.subject.otherComputed radiography
dc.subject.otherruleâ based classification
dc.subject.otherlinear discriminant analysis
dc.titleLung nodule detection on thoracic computed tomography images: Preliminary evaluation of a computerâ aided diagnosis system
dc.typeArticleen_US
dc.rights.robotsIndexNoFollow
dc.subject.hlbsecondlevelMedicine (General)
dc.subject.hlbtoplevelHealth Sciences
dc.description.peerreviewedPeer Reviewed
dc.contributor.affiliationumDepartment of Radiology, University of Michigan, Ann Arbor, Michigan 48109â 0904
dc.description.bitstreamurlhttp://deepblue.lib.umich.edu/bitstream/2027.42/135039/1/mp5762.pdf
dc.identifier.doi10.1118/1.1515762
dc.identifier.sourceMedical Physics
dc.identifier.citedreferenceAmerican Cancer Society, â American Cancer Societyâ Cancer Facts and Figures 2001,â www.cancer.org (2001).
dc.identifier.citedreferenceJ. W. Gurney, â Missed lung cancer at CT: imaging findings in nine patients,â Radiology RADLAX --> 199, 117 â 122 ( 1996 ). RADLAX --> 0033â 8419
dc.identifier.citedreferenceC. S. White, B. M. Romney, A. C. Mason, J. H. M. Austin, B. H. Miller, and Z. Protopapas, â Primary carcinoma of the lung overlooked at CT: analysis of fings in 14 patients,â Radiology RADLAX --> 199, 109 â 115 ( 1996 ). RADLAX --> 0033â 8419
dc.identifier.citedreferenceM. Kaneko, K. Eguchi, H. Ohmatsu, R. Kakinuma, T. Naruke, K. Suemasu, and N. Moriyama, â Peripheral lung cancer: screening and detection with lowâ dose spiral CT versus radiography,â Radiology RADLAX --> 201, 798 â 802 ( 1996 ). RADLAX --> 0033â 8419
dc.identifier.citedreferenceS. Sone et al., â Mass screening for lung cancer with mobile spiral computed tomography scanner,â Lancet LANCAO --> 352, 1242 â 1245 ( 1998 ). LANCAO --> 0140â 6736
dc.identifier.citedreferenceC. I. Henschke et al., â Early lung cancer action project: overall design and findings from baseline screening,â Lancet LANCAO --> 354, 99 â 105 ( 1999 ). LANCAO --> 0140â 6736
dc.identifier.citedreferenceG. M. Strauss, R. E. Gleason, and D. J. Sugarbaker, â Screening for lung cancer: Another look; A different view,â Chest CHETBF --> 111, 754 â 768 ( 1997 ). CHETBF --> 0012â 3692
dc.identifier.citedreferenceNational Cancer Institute, â Surveillance, Epidemiology, and End Results (SEER) Program Publicâ Use CDâ ROM (1973â 1997),â DCCPS, Cancer Surveillance Research Program, Cancer Statistics Branch, 2000.
dc.identifier.citedreferenceB. S. Brown, M. F. McNittâ Gray, N. J. Mankovich, J. G. Goldin, J. Hiller, L. S. Wilson, and D. R. Aberle, â Method for segmenting chest CT image data using an anatomical model: Preliminary results,â IEEE Trans. Med. Imaging ITMID4 --> 16, 828 â 839 ( 1997 ). ITMID4 --> 0278â 0062
dc.identifier.citedreferenceP. C. Bunch, J. F. Hamilton, G. K. Sanderson, and A. H. Simmons, â A free response approach to the measurement and characterization of radiographic observer performance,â J. Appl. Photogr. Eng. JAPEDL --> 4, 166 â 171 ( 1978 ). JAPEDL --> 0098â 7298
dc.identifier.citedreferenceH. P. Chan, D. Wei, M. A. Helvie, B. Sahiner, D. D. Adler, M. M. Goodsitt, and N. Petrick, â Computerâ aided classification of mammographic masses and normal tissue: Linear discriminant analysis in texture feature space,â Phys. Med. Biol. PHMBA7 --> 40, 857 â 876 ( 1995 ). PHMBA7 --> 0031â 9155
dc.identifier.citedreferenceR. O. Duda and P. E. Hart, Pattern Classification and Scene Analysis (Wiley, New York, 1973).
dc.identifier.citedreferenceS. G. Erberich, K. S. Song, H. Arakawa, H. K. Huang, R. Webb, K. S. Hoo, and B. W. Loo, â Knowledgeâ based lung nodule detection from helical CT,â Radiology RADLAX --> 205, 617 ( 1997 ). RADLAX --> 0033â 8419
dc.identifier.citedreferenceW. K. Pratt, Digital Imaging Processing, 2nd ed. (Wiley, New York, 1991).
dc.identifier.citedreferenceB. Sahiner, H. P. Chan, N. Petrick, D. Wei, M. A. Helvie, D. D. Alder, and M. M. Goodsitt, â Image feature selection by a genetic algorithm: Application to classification of mass and normal breast tissue on mammograms,â Med. Phys. MPHYA6 --> 23, 1671 â 1684 ( 1996 ). MPHYA6 --> 0094â 2405
dc.identifier.citedreferenceM. Gurcan, N. Petrick, B. Sahiner, H. P. Chan, P. N. Cascade, E. Kazerooni, and L. M. Hadjiiski, â Computerized lung nodule detection on thoracic CT images: combined ruleâ based and statistical classifier for false positive reduction,â Proc. SPIE PSISDG --> 4322, 686 â 692 ( 2001 ). PSISDG --> 0277â 786X
dc.identifier.citedreferenceT. Hara, H. Fujita, Y. Lee, H. Yoshimura, and S. Kido, Automated lesion detection methods for 2D and 3D chest xâ ray images, 27â 29 September 1999.
dc.identifier.citedreferenceJ. P. Ko and M. Betke, â Chest CT: Automated nodule detection and assessment of change over timeâ preliminary experience,â Radiology RADLAX --> 2001, 267 â 273 ( 2001 ). RADLAX --> 0033â 8419
dc.identifier.citedreferenceS. G. Armato, M. L. Giger, and H. MacMahon, â Automated detection of lung nodules in CT scans: Preliminary results,â Med. Phys. MPHYA6 --> 28, 1552 â 1561 ( 2001 ). MPHYA6 --> 0094â 2405
dc.identifier.citedreferenceS. G. Armato, M. L. Giger, K. Doi, and H. MacMahon, â Computerized lung nodule detection: Comparison of performance for lowâ dose and standardâ dose helical CT scans,â Proc. SPIE PSISDG --> 4322, 1449 â 1454 ( 2001 ). PSISDG --> 0277â 786X
dc.identifier.citedreferenceD. Wormanns, M. Fiebich, C. Wietholt, S. Diederich, and W. Heindel, â Automatic detection of pulmonary nodules at spiral CTâ first clinical experience with a computerâ aided diagnosis system,â Proc. SPIE PSISDG --> 3979, 129 â 135 ( 2000 ). PSISDG --> 0277â 786X
dc.identifier.citedreferenceS. G. Armato, M. L. Giger, J. T. Blackburn, K. Doi, and H. MacMahon, â Threeâ dimensional approach to lung nodule detection in helical CT,â Proc. SPIE PSISDG --> 3662, 553 â 559 ( 1999 ). PSISDG --> 0277â 786X
dc.identifier.citedreferenceM. Fiebich, C. Wietholt, B. C. Renger, S. G. Armato, K. R. Hoffmann, and S. Dietrich, â Automatic detection of pulmonary nodules in lowâ dose screening thoracic CT examinations,â Proc. SPIE PSISDG --> 3661, 1434 â 1439 ( 1999 ). PSISDG --> 0277â 786X
dc.identifier.citedreferenceS. L. Lou, C. L. Chang, K. P. Lin, and T. S. Chen, â Objectâ based deformation technique for 3â D CT lung nodule detection,â Proc. SPIE PSISDG --> 3661, 1544 â 1552 ( 1999 ). PSISDG --> 0277â 786X
dc.identifier.citedreferenceH. Satoh, Y. Ukai, N. Niki, K. Eguchi, K. Mori, H. Ohmatsu, R. Kakinuma, M. Kaneko, and M. Moriyama, â Computer aided diagnosis system for lung cancer based on retrospective helical CT image,â Proc. SPIE PSISDG --> 3661, 1324 â 1335 ( 1999 ). PSISDG --> 0277â 786X
dc.identifier.citedreferenceK. Kanazawa, Y. Kawata, N. Niki, H. Satoh, H. Ohmatsu, R. Kakinuma, M. Kaneko, N. Moriyama, and K. Eguchi, â Computerâ aided diagnosis for pulmonary nodules based on helical CT images,â Comput. Med. Imag. Graph., 157â 167 (1998).
dc.identifier.citedreferenceT. W. Freer and M. J. Ulissey, â Screening mammography with computerâ aided detection: Prospective study of 12,860 patients in a community breast center,â Radiology RADLAX --> 220, 781 â 786 ( 2001 ). RADLAX --> 0033â 8419
dc.identifier.citedreferenceR. Kakinuma, H. Ohmatsu, M. Kaneko, K. Eguchi, T. Naruke, K. Nagai, Y. Nishiwaki, A. Suzuki, and N. Moriyama, â Detection failures in spiral CT screening for lung cancer: analysis of CT findings,â Radiology RADLAX --> 212, 61 â 66 ( 1999 ). RADLAX --> 0033â 8419
dc.identifier.citedreferenceS. D. Davis, â Through the â retrospectoscopeâ : a glimpse of missed lung cancer at CT,â Radiology RADLAX --> 199, 23 â 24 ( 1996 ). RADLAX --> 0033â 8419
dc.owningcollnameInterdisciplinary and Peer-Reviewed


Files in this item

Show simple item record

Remediation of Harmful Language

The University of Michigan Library aims to describe library materials in a way that respects the people and communities who create, use, and are represented in our collections. Report harmful or offensive language in catalog records, finding aids, or elsewhere in our collections anonymously through our metadata feedback form. More information at Remediation of Harmful Language.

Accessibility

If you are unable to use this file in its current format, please select the Contact Us link and we can modify it to make it more accessible to you.