Automating linear accelerator quality assurance

dc.contributor.authorEckhause, Tobias
dc.contributor.authorAl‐hallaq, Hania
dc.contributor.authorRitter, Timothy
dc.contributor.authorDeMarco, John
dc.contributor.authorFarrey, Karl
dc.contributor.authorPawlicki, Todd
dc.contributor.authorKim, Gwe‐ya
dc.contributor.authorPopple, Richard
dc.contributor.authorSharma, Vijeshwar
dc.contributor.authorPerez, Mario
dc.contributor.authorPark, SungYong
dc.contributor.authorBooth, Jeremy T.
dc.contributor.authorThorwarth, Ryan
dc.contributor.authorMoran, Jean M.
dc.date.accessioned2017-01-06T20:49:59Z
dc.date.available2017-01-06T20:49:59Z
dc.date.issued2015-10
dc.identifier.citationEckhause, Tobias; Al‐hallaq, Hania ; Ritter, Timothy; DeMarco, John; Farrey, Karl; Pawlicki, Todd; Kim, Gwe‐ya ; Popple, Richard; Sharma, Vijeshwar; Perez, Mario; Park, SungYong; Booth, Jeremy T.; Thorwarth, Ryan; Moran, Jean M. (2015). "Automating linear accelerator quality assurance." Medical Physics 42(10): 6074-6083.
dc.identifier.issn0094-2405
dc.identifier.issn2473-4209
dc.identifier.urihttps://hdl.handle.net/2027.42/135049
dc.publisherWiley Periodicals, Inc.
dc.publisherAmerican Association of Physicists in Medicine
dc.subject.otherEPID
dc.subject.otherbiomedical imaging
dc.subject.othercollimators
dc.subject.otherlinear accelerators
dc.subject.otherquality assurance
dc.subject.otherradiation therapy
dc.subject.otherQuality assurance equipment
dc.subject.otherCollimators
dc.subject.otherAccelerators
dc.subject.otherQuality assurance in radiotherapy
dc.subject.otherOptimization
dc.subject.otherRadiation therapy
dc.subject.otherBiological material, e.g. blood, urine; Haemocytometers
dc.subject.otherUsing diaphragms, collimators
dc.subject.otherLinear accelerators
dc.subject.otherquality assurance
dc.subject.otherlinear accelerator
dc.subject.othermultileaf collimator
dc.subject.otherquality control
dc.subject.otherLinear accelerators
dc.subject.otherImage guided radiation therapy
dc.subject.otherMedical imaging
dc.subject.otherMultileaf collimators
dc.subject.otherImage analysis
dc.subject.otherCollimators
dc.subject.otherIntensity modulated radiation therapy
dc.subject.otherComputer software
dc.subject.otherQuality assurance
dc.subject.otherData analysis
dc.titleAutomating linear accelerator quality assurance
dc.typeArticleen_US
dc.rights.robotsIndexNoFollow
dc.subject.hlbsecondlevelMedicine (General)
dc.subject.hlbtoplevelHealth Sciences
dc.description.peerreviewedPeer Reviewed
dc.contributor.affiliationumDepartment of Radiation Oncology, University of Michigan, Ann Arbor, Michigan 48109â 5010
dc.contributor.affiliationumDepartment of Radiation Oncology, University of Michigan, Ann Arbor, Michigan 48109â 5010
dc.contributor.affiliationotherDepartment of Radiation Oncology and Cellular Oncology, The University of Chicago, Chicago, Illinois 60637
dc.contributor.affiliationotherAnn Arbor VA Medical Center, Ann Arbor, Michigan 48109
dc.contributor.affiliationotherDepartment of Radiation Oncology, Cedarsâ Sinai Medical Center, Los Angeles, California, 90048
dc.contributor.affiliationotherDepartment of Radiation Oncology and Cellular Oncology, The University of Chicago, Chicago, Illinois 60637
dc.contributor.affiliationotherUCSD Medical Center, La Jolla, California 92093
dc.contributor.affiliationotherDepartment of Radiation Oncology, University of Alabama Birmingham, Birmingham, Alabama 35249
dc.contributor.affiliationotherKarmanos Cancer Institute, McLarenâ Flint, Flint, Michigan 48532
dc.contributor.affiliationotherRoyal North Shore Hospital, Sydney, NSW 2065, Australia
dc.contributor.affiliationotherKarmanos Cancer Institute, McLarenâ Flint, Flint, Michigan 48532
dc.contributor.affiliationotherRoyal North Shore Hospital, Sydney, NSW 2065, Australia
dc.description.bitstreamurlhttp://deepblue.lib.umich.edu/bitstream/2027.42/135049/1/mp1415.pdf
dc.identifier.doi10.1118/1.4931415
dc.identifier.sourceMedical Physics
dc.identifier.citedreferenceVarian TrueBeam Technical Reference Guide, Vol. 1, pp. 54â 58. Resolvers provide rotational position of a motor calibrated to a hard stop.
dc.identifier.citedreferenceW. Du, S. Gao, X. Wang, and R. J. Kudchadker, â Quantifying the gantry sag on linear accelerators and introducing an MLCâ based compensation strategy,â Med. Phys. 39, 2156 â 2162 ( 2012 ). 10.1118/1.3697528
dc.identifier.citedreferenceT. Losasso, â IMRT delivery performance with a varian multileaf collimator,â Int. J. Radiat. Oncol., Biol., Phys. 71, S85 â S88 ( 2008 ). 10.1016/j.ijrobp.2007.06.082
dc.identifier.citedreferenceR. A. Popple and I. A. Brezovich, â Dynamic MLC leaf sequencing for integrated linear accelerator control systems,â Med. Phys. 38, 6039 â 6045 ( 2011 ). 10.1118/1.3651628
dc.identifier.citedreferenceJ. Li, R. D. Wiersma, C. J. Stepaniak, K. J. Farrey, and H. A. Alâ Hallaq, â Improvements in dose accuracy delivered with staticâ MLC IMRT on an integrated linear accelerator control system,â Med. Phys. 39, 2456 â 2462 ( 2012 ). 10.1118/1.3701778
dc.identifier.citedreferenceE. E. Klein, J. Hanley, J. Bayouth, F. F. Yin, W. Simon, S. Dresser, C. Serago, F. Aguirre, L. Ma, B. Arjomandy, C. Liu, C. Sandin, and T. Holmes, â Task Group 142 Report: Quality assurance of medical accelerators,â Med. Phys. 36, 4197 â 4212 ( 2009 ). 10.1118/1.3190392
dc.identifier.citedreferenceJ. Chang, C. H. Obcemea, J. Sillanpaa, J. Mechalakos, and C. Burman, â Use of EPID for leaf position accuracy QA of dynamic multiâ leaf collimator (DMLC) treatment,â Med. Phys. 31, 2091 â 2096 ( 2004 ). 10.1118/1.1760187
dc.identifier.citedreferenceJ. I. Prisciandaro, C. M. Frechette, M. G. Herman, P. D. Brown, Y. I. Garces, and R. L. Foote, â A methodology to determine margins by EPID measurements of patient setup variation and motion as applied to immobilization devices,â Med. Phys. 31, 2978 â 2988 ( 2004 ). 10.1118/1.1800712
dc.identifier.citedreferenceM. Mamaluiâ Hunter, H. Li, and D. A. Low, â MLC quality assurance using EPID: A fitting technique with subpixel precision,â Med. Phys. 35, 2347 â 2355 ( 2008 ). 10.1118/1.2919560
dc.identifier.citedreferenceP. M. McCowan, D. W. Rickey, P. Rowshanfarzad, P. B. Greer, W. Ansbacher, and B. M. McCurdy, â An investigation of gantry angle data accuracy for cineâ mode EPID images acquired during arc IMRT,â J. Appl. Clin. Med. Phys. 15, 187 â 201 ( 2014 ).
dc.identifier.citedreferenceP. Rowshanfarzad, M. Sabet, M. P. Barnes, D. J. O’Connor, and P. B. Greer, â EPIDâ based verification of the MLC performance for dynamic IMRT and VMAT,â Med. Phys. 39, 6192 â 6207 ( 2012 ). 10.1118/1.4752207
dc.identifier.citedreferenceJ. G. Li, J. F. Dempsey, L. Ding, C. Liu, and J. R. Palta, â Validation of dynamic MLCâ controller log files using a twoâ dimensional diode array,â Med. Phys. 30, 799 â 805 ( 2003 ). 10.1118/1.1567951
dc.identifier.citedreferenceD. W. Litzenberg, J. M. Moran, and B. A. Fraass, â Verification of dynamic and segmental IMRT delivery by dynamic log file analysis,â J. Appl. Clin. Med. Phys. 3, 63 â 72 ( 2002 ). 10.1120/jacmp.v3i2.2578
dc.identifier.citedreferenceD. W. Litzenberg, J. M. Moran, and B. A. Fraass, â Incorporation of realistic delivery limitations into dynamic MLC treatment delivery,â Med. Phys. 29, 810 â 820 ( 2002 ). 10.1118/1.1470499
dc.identifier.citedreferenceP. R. Poulsen, B. Cho, A. Sawant, D. Ruan, and P. J. Keall, â Dynamic MLC tracking of moving targets with a single kV imager for 3D conformal and IMRT treatments,â Acta Oncol. 49, 1092 â 1100 ( 2010 ). 10.3109/0284186X.2010.498438
dc.identifier.citedreferenceP. Dong, P. Lee, D. Ruan, T. Long, E. Romeijn, Y. Yang, D. Low, P. Kupelian, and K. Sheng, â 4pi nonâ coplanar liver SBRT: A novel delivery technique,â Int. J. Radiat. Oncol., Biol., Phys. 85, 1360 â 1366 ( 2013 ). 10.1016/j.ijrobp.2012.09.028
dc.identifier.citedreferenceW. van Elmpt, L. McDermott, S. Nijsten, M. Wendling, P. Lambin, and B. Mijnheer, â A literature review of electronic portal imaging for radiotherapy dosimetry,â Radiother. Oncol. 88, 289 â 309 ( 2008 ). 10.1016/j.radonc.2008.07.008
dc.identifier.citedreferenceC. Glideâ Hurst, M. Bellon, R. Foster, C. Altunbas, M. Speiser, M. Altman, D. Westerly, N. Wen, B. Zhao, M. Miften, I. J. Chetty, and T. Solberg, â Commissioning of the Varian TrueBeam linear accelerator: A multiâ institutional study,â Med. Phys. 40, 031719 (15pp.) ( 2013 ). 10.1118/1.4790563
dc.identifier.citedreferenceJ. M. Moran, J. Radawski, and B. A. Fraass, â A dose gradient analysis tool for IMRT QA,â J. Appl. Clin. Med. Phys. 6, 62 â 73 ( 2005 ). 10.1120/jacmp.v6i2.2006
dc.identifier.citedreferenceB. Sun, D. Rangaraj, G. Palaniswaamy, S. Sridhar, O. Wooten, D. Yang, S. Mutic, and L. Santanam, â Initial experience with TrueBeam trajectory log files for radiation therapy delivery verification,â Pract. Radiat. Oncol. 3, e199 â e208 ( 2013 ). 10.1016/j.prro.2012.11.013
dc.identifier.citedreferenceW. van Elmpt, S. Nijsten, S. Petit, B. Mijnheer, P. Lambin, and A. Dekker, â 3D in vivo dosimetry using megavoltage coneâ beam CT and EPID dosimetry,â Int. J. Radiat. Oncol., Biol., Phys. 73, 1580 â 1587 ( 2009 ). 10.1016/j.ijrobp.2008.11.051
dc.identifier.citedreferenceA. Agnew, C. E. Agnew, M. W. Grattan, A. R. Hounsell, and C. K. McGarry, â Monitoring daily MLC positional errors using trajectory log files and EPID measurements for IMRT and VMAT deliveries,â Phys. Med. Biol. 59, N49 â N63 ( 2014 ). 10.1088/0031â 9155/59/9/N49
dc.identifier.citedreferenceG. A. Ezzell, J. W. Burmeister, N. Dogan, T. J. LoSasso, J. G. Mechalakos, D. Mihailidis, A. Molineu, J. R. Palta, C. R. Ramsey, B. J. Salter, J. Shi, P. Xia, N. J. Yue, and Y. Xiao, â IMRT commissioning: Multiple institution planning and dosimetry comparisons, a Report from AAPM Task Group 119,â Med. Phys. 36, 5359 â 5373 ( 2009 ). 10.1118/1.3238104
dc.identifier.citedreferenceS. Gao, W. Du, P. Balter, P. Munro, and A. Jeung, â Evaluation of IsoCal geometric calibration system for Varian linacs equipped with onâ board imager and electronic portal imaging device imaging systems,â J. Appl. Clin. Med. Phys. 15, 164 â 181 ( 2014 ).
dc.identifier.citedreferenceP. Rowshanfarzad, M. Sabet, D. J. O’Connor, P. M. McCowan, B. M. McCurdy, and P. B. Greer, â Detection and correction for EPID and gantry sag during arc delivery using cine EPID imaging,â Med. Phys. 39, 623 â 635 ( 2012 ). 10.1118/1.3673958
dc.owningcollnameInterdisciplinary and Peer-Reviewed


Files in this item

Show simple item record

Remediation of Harmful Language

The University of Michigan Library aims to describe library materials in a way that respects the people and communities who create, use, and are represented in our collections. Report harmful or offensive language in catalog records, finding aids, or elsewhere in our collections anonymously through our metadata feedback form. More information at Remediation of Harmful Language.

Accessibility

If you are unable to use this file in its current format, please select the Contact Us link and we can modify it to make it more accessible to you.