Highâ DQE EPIDs based on thick, segmented BGO and CsI:Tl scintillators: Performance evaluation at extremely low dose
dc.contributor.author | Wang, Yi | |
dc.contributor.author | Antonuk, Larry E. | |
dc.contributor.author | Zhao, Qihua | |
dc.contributor.author | El‐mohri, Youcef | |
dc.contributor.author | Perna, Louis | |
dc.date.accessioned | 2017-01-06T20:50:12Z | |
dc.date.available | 2017-01-06T20:50:12Z | |
dc.date.issued | 2009-12 | |
dc.identifier.citation | Wang, Yi; Antonuk, Larry E.; Zhao, Qihua; El‐mohri, Youcef ; Perna, Louis (2009). "Highâ DQE EPIDs based on thick, segmented BGO and CsI:Tl scintillators: Performance evaluation at extremely low dose." Medical Physics 36(12): 5707-5718. | |
dc.identifier.issn | 0094-2405 | |
dc.identifier.issn | 2473-4209 | |
dc.identifier.uri | https://hdl.handle.net/2027.42/135060 | |
dc.publisher | Wiley Periodicals, Inc. | |
dc.publisher | American Association of Physicists in Medicine | |
dc.subject.other | segmented scintillators | |
dc.subject.other | DQE | |
dc.subject.other | Medical imaging | |
dc.subject.other | Image guided radiation therapy | |
dc.subject.other | Modulation transfer functions | |
dc.subject.other | Medical Xâ ray imaging | |
dc.subject.other | Photons | |
dc.subject.other | Mirrors | |
dc.subject.other | Dosimetry | |
dc.subject.other | Xâ ray optics | |
dc.subject.other | Linear accelerators | |
dc.subject.other | Cone beam computed tomography | |
dc.subject.other | dosimetry | |
dc.subject.other | Dosimetry/exposure assessment | |
dc.subject.other | Therapeutic applications, including brachytherapy | |
dc.subject.other | Computed tomography | |
dc.subject.other | Scintillation detectors | |
dc.subject.other | computerised tomography | |
dc.subject.other | phantoms | |
dc.subject.other | radiation therapy | |
dc.subject.other | solid scintillation detectors | |
dc.subject.other | megavoltage xâ ray imaging | |
dc.subject.other | flatâ panel imager | |
dc.subject.other | EPID | |
dc.title | Highâ DQE EPIDs based on thick, segmented BGO and CsI:Tl scintillators: Performance evaluation at extremely low dose | |
dc.type | Article | en_US |
dc.rights.robots | IndexNoFollow | |
dc.subject.hlbsecondlevel | Medicine (General) | |
dc.subject.hlbtoplevel | Health Sciences | |
dc.description.peerreviewed | Peer Reviewed | |
dc.contributor.affiliationum | Department of Radiation Oncology, University of Michigan, Ann Arbor, Michigan 48109 | |
dc.contributor.affiliationother | Saintâ Gobain Crystals, 17900 Great Lakes Parkway, Hiram, Ohio 44234 | |
dc.description.bitstreamurl | http://deepblue.lib.umich.edu/bitstream/2027.42/135060/1/mp9721.pdf | |
dc.identifier.doi | 10.1118/1.3259721 | |
dc.identifier.source | Medical Physics | |
dc.identifier.citedreference | Y. Wang, L. E. Antonuk, Y. Elâ Mohri, and Q. Zhao, â A Monte Carlo investigation of Swank noise for thick, segmented, crystalline scintillating detectors for radiotherapy imaging,â Med. Phys. MPHYA6 --> 0094‐2405 --> 36, 3227 â 3238 ( 2009 ). 10.1118/1.3125821 | |
dc.identifier.citedreference | H. Keller, M. Glass, R. Hinderer, K. Ruchala, R. Jeraj, G. Olivera, and T. R. Mackie, â Monte Carlo study of a highly efficient gas ionization detector for megavoltage imaging and imageâ guided radiotherapy,â Med. Phys. MPHYA6 --> 0094‐2405 --> 29, 165 â 175 ( 2002 ). 10.1118/1.1445414 | |
dc.identifier.citedreference | G. Pang and J. A. Rowlands, â Development of high quantum efficiency, flat panel, thick detectors for megavoltage xâ ray imaging: A novel directâ conversion design and its feasibility,â Med. Phys. MPHYA6 --> 0094‐2405 --> 31, 3004 â 3016 ( 2004 ). 10.1118/1.1803771 | |
dc.identifier.citedreference | Q. Zhao, L. E. Antonuk, Y. Elâ Mohri, H. Du, Y. Li, A. Sawant, Z. Su, Y. Wang, and J. Yamamoto, â High DQE megavoltage imaging using active matrix flatâ panel imagers incorporating polycrystalline mercuric iodide,â Med. Phys. MPHYA6 --> 0094‐2405 --> 32, 2131 ( 2005 ). 10.1118/1.1998538 | |
dc.identifier.citedreference | X. Mei, J. A. Rowlands, and G. Pang, â Electronic portal imaging based on Cerenkov radiation: A new approach and its feasibility,â Med. Phys. MPHYA6 --> 0094‐2405 --> 33, 4258 â 4270 ( 2006 ). 10.1118/1.2362875 | |
dc.identifier.citedreference | A. Sawant, L. E. Antonuk, Y. Elâ Mohri, Y. Li, Z. Su, Y. Wang, J. Yamamoto, Q. Zhao, H. Du, J. Daniel, and R. A. Street, â Segmented phosphorsâ MEMSâ based high quantum efficiency detectors for megavoltage xâ ray imaging,â Med. Phys. MPHYA6 --> 0094‐2405 --> 32, 553 â 565 ( 2005 ). 10.1118/1.1854774 | |
dc.identifier.citedreference | E. J. Morton, W. Swindell, D. G. Lewis, and P. M. Evans, â A linear array, scintillation crystalâ photodiode detector for megavoltage imaging,â Med. Phys. MPHYA6 --> 0094‐2405 --> 18, 681 â 691 ( 1991 ). 10.1118/1.596661 | |
dc.identifier.citedreference | D. G. Lewis, W. Swindell, E. J. Morton, P. M. Evans, and Z. R. Xiao, â A megavoltage CT scanner for radiotherapy verification,â Phys. Med. Biol. PHMBA7 --> 0031‐9155 --> 37, 1985 â 1999 ( 1992 ). 10.1088/0031â 9155/37/10/013 | |
dc.identifier.citedreference | M. A. Moslehâ Shirazi, P. M. Evans, W. Swindell, J. R. Symondsâ Tayler, S. Webb, and M. Partridge, â Rapid portal imaging with a highâ efficiency, large fieldâ ofâ view detector,â Med. Phys. MPHYA6 --> 0094‐2405 --> 25, 2333 â 2346 ( 1998 ). 10.1118/1.598443 | |
dc.identifier.citedreference | M. A. Moslehâ Shirazi, P. M. Evans, W. Swindell, S. Webb, and M. Partridge, â A coneâ beam megavoltage CT scanner for treatment verification in conformal radiotherapy,â Radiother. Oncol. RAONDT --> 0167‐8140 --> 48, 319 â 328 ( 1998 ). 10.1016/S0167â 8140(98)00042â 5 | |
dc.identifier.citedreference | M. A. Moslehâ Shirazi, W. Swindell, and P. M. Evans, â Optimization of the scintillation detector in a combined 3D megavoltage CT scanner and portal imager,â Med. Phys. MPHYA6 --> 0094‐2405 --> 25, 1880 â 1890 ( 1998 ). 10.1118/1.598377 | |
dc.identifier.citedreference | S. Rathee, D. Tu, T. T. Monajemi, D. W. Rickey, and B. G. Fallone, â A benchâ top megavoltage fanâ beam CT using CdWO4â photodiode detectors. I. System description and detector characterization,â Med. Phys. MPHYA6 --> 0094‐2405 --> 33, 1078 â 1089 ( 2006 ). 10.1118/1.2181290 | |
dc.identifier.citedreference | T. T. Monajemi, D. Tu, B. G. Fallone, and S. Rathee, â A benchâ top megavoltage fanâ beam CT using CdWO4â photodiode detectors. II. Image performance evaluation,â Med. Phys. MPHYA6 --> 0094‐2405 --> 33, 1090 â 1100 ( 2006 ). 10.1118/1.2181291 | |
dc.identifier.citedreference | T. T. Monajemi, B. G. Fallone, and S. Rathee, â Thick, segmented CdWO4â photodiode detector for cone beam megavoltage CT: A Monte Carlo study of system design parameters,â Med. Phys. MPHYA6 --> 0094‐2405 --> 33, 4567 â 4577 ( 2006 ). 10.1118/1.2370503 | |
dc.identifier.citedreference | S. S. Samant and A. Gopal, â Study of a prototype high quantum efficiency thick scintillation crystal videoâ electronic portal imaging device,â Med. Phys. MPHYA6 --> 0094‐2405 --> 33, 2783 â 2791 ( 2006 ). 10.1118/1.2216877 | |
dc.identifier.citedreference | E. J. Seppi, P. Munro, S. W. Johnsen, E. G. Shapiro, C. Tognina, D. Jones, J. M. Pavkovich, C. Webb, I. Mollov, L. D. Partain, and R. E. Colbeth, â Megavoltage coneâ beam computed tomography using a highâ efficiency image receptor,â Int. J. Radiat. Oncol., Biol., Phys. IOBPD3 --> 0360‐3016 --> 55, 793 â 803 ( 2003 ). 10.1016/S0360â 3016(02)04155â X | |
dc.identifier.citedreference | A. Sawant, L. E. Antonuk, Y. Elâ Mohri, Q. Zhao, Y. Li, Z. Su, Y. Wang, J. Yamamoto, H. Du, I. Cunningham, M. Klugerman, and K. Shah, â Segmented crystalline scintillators: An initial investigation of high quantum efficiency detectors for megavoltage xâ ray imaging,â Med. Phys. MPHYA6 --> 0094‐2405 --> 32, 3067 â 3083 ( 2005 ). 10.1118/1.2008407 | |
dc.identifier.citedreference | A. Sawant, L. E. Antonuk, Y. Elâ Mohri, Q. Zhao, Y. Wang, Y. Li, H. Du, and L. Perna, â Segmented crystalline scintillators: Empirical and theoretical investigation of a high quantum efficiency EPID based on an initial engineering prototype CsI(Tl) detector,â Med. Phys. MPHYA6 --> 0094‐2405 --> 33, 1053 â 1066 ( 2006 ). 10.1118/1.2178452 | |
dc.identifier.citedreference | Y. Wang, L. E. Antonuk, Y. Elâ Mohri, Q. Zhao, A. Sawant, and H. Du, â Monte Carlo investigations of megavoltage coneâ beam CT using thick, segmented scintillating detectors for soft tissue visualization,â Med. Phys. MPHYA6 --> 0094‐2405 --> 35, 145 â 158 ( 2008 ). 10.1118/1.2818957 | |
dc.identifier.citedreference | Y. Wang, L. E. Antonuk, Y. Elâ Mohri, A. Sawant, Q. Zhao, H. Du, and Y. Li, â Theoretical investigation of very high quantum efficiency, segmented, crystalline detectors for lowâ contrast visualization in megavoltage coneâ beam CT,â Proc. SPIE PSISDG --> 0277‐786X --> 6142, 61421P ( 2006 ). 10.1117/12.654873 | |
dc.identifier.citedreference | J. C. Dainty and R. Shaw, Image Science: Principles, Analysis and Evaluation of Photographic Type Imaging Processes ( Academic, London, 1974 ). | |
dc.identifier.citedreference | M. L. Giger, K. Doi, and C. E. Metz, â Investigation of basic imaging properties in digital radiography. 2. Noise Wiener spectrum,â Med. Phys. MPHYA6 --> 0094‐2405 --> 11, 797 â 805 ( 1984 ). 10.1118/1.595583 | |
dc.identifier.citedreference | A. D. Maidment and M. J. Yaffe, â Analysis of the spatialâ frequencyâ dependent DQE of optically coupled digital mammography detectors,â Med. Phys. MPHYA6 --> 0094‐2405 --> 21, 721 â 729 ( 1994 ). 10.1118/1.597331 | |
dc.identifier.citedreference | L. E. Antonuk, Y. Elâ Mohri, J. H. Siewerdsen, J. Yorkston, W. Huang, V. E. Scarpine, and R. A. Street, â Empirical investigation of the signal performance of a highâ resolution, indirect detection, active matrix flatâ panel imager (AMFPI) for fluoroscopic and radiographic operation,â Med. Phys. MPHYA6 --> 0094‐2405 --> 24, 51 â 70 ( 1997 ). 10.1118/1.597918 | |
dc.identifier.citedreference | H. Fujita, D. Y. Tsai, T. Itoh, K. Doi, J. Morishita, K. Ueda, and A. Ohtsuka, â A simple method for determining the modulation transferâ function in digital radiography,â IEEE Trans. Med. Imaging ITMID4 --> 0278‐0062 --> 11, 34 â 39 ( 1992 ). 10.1109/42.126908 | |
dc.identifier.citedreference | A. Sawant, L. E. Antonuk, and Y. Elâ Mohri, â Slit design for efficient and accurate MTF measurement at megavoltage xâ ray energies,â Med. Phys. MPHYA6 --> 0094‐2405 --> 34, 1535 â 1545 ( 2007 ). 10.1118/1.2717405 | |
dc.identifier.citedreference | L. E. Antonuk, Y. Elâ Mohri, W. Huang, K. â W. Jee, J. H. Siewerdsen, M. Maolinbay, V. E. Scarpine, H. Sandler, and J. Yorkston, â Initial performance evaluation of an indirectâ detection, active matrix flatâ panel imager (AMFPI) prototype for megavoltage imaging,â Int. J. Radiat. Oncol., Biol., Phys. IOBPD3 --> 0360‐3016 --> 42, 437 â 454 ( 1998 ). 10.1016/S0360â 3016(98)00210â 7 | |
dc.identifier.citedreference | I. Kawrakow and D. W. O. Rogers, The EGSnrc code system: Monte Carlo simulation of electron and photon transport, Ottawa, Canada ( 2000 ). | |
dc.identifier.citedreference | J. A. Treurniet, B. R. B. Walters, and D. W. O. Rogers, BEAMnrc, DOSXYZnrc and BEAMDP GUI User’s Manual, Ottawa, Canada ( 2001 ). | |
dc.identifier.citedreference | D. Sheikhâ Bagheri, Ph.D. thesis, Carleton University, 1999. | |
dc.identifier.citedreference | I. A. Cunningham, in Handbook of Medical Imaging, edited by J. Beutel, H. L. Kundel, and R. L. van Metter ( SPIE, Bellingham, WA, 2000 ), Vol. 1, pp. 79 â 160. | |
dc.identifier.citedreference | Z. Y. Wei, R. Y. Zhu, H. Newman, and Z. W. Yin, â Radiation resistance and fluorescence of europium doped BGO crystals,â Nucl. Instrum. Methods Phys. Res. A NIMAER --> 0168‐9002 --> 297, 163 â 168 ( 1990 ). 10.1016/0168â 9002(90)91362â F | |
dc.identifier.citedreference | R. Y. Zhu, H. Stone, H. Newman, T. Q. Zhou, H. R. Tan, and C. F. He, â A study on radiation damage in doped BGO crystals,â Nucl. Instrum. Methods Phys. Res. A NIMAER --> 0168‐9002 --> 302, 69 â 75 ( 1991 ). 10.1016/0168â 9002(91)90493â A | |
dc.identifier.citedreference | R. Y. Zhu, D. A. Ma, and H. Newman, â Scintillating crystals in a radiation environment,â Nucl. Phys. B NUPBBO --> 0550‐3213 --> 44, 547 â 556 ( 1995 ). | |
dc.identifier.citedreference | R. Y. Zhu, â Radiation damage in scintillating crystals,â Nucl. Instrum. Methods Phys. Res. A NIMAER --> 0168‐9002 --> 413, 297 â 311 ( 1998 ). 10.1016/S0168â 9002(98)00498â 7 | |
dc.identifier.citedreference | J. H. Kim, N. E. Yu, and B. M. Jin, â Eu doping effect on the radiation resistance in Bi4Ge3O12 (BGO) scintillator,â J. Korean Phys. Soc. KPSJAS --> 0374‐4884 --> 32, S1123 â S1126 ( 1998 ). | |
dc.identifier.citedreference | R. Georgii, R. Meiï¬ l, W. Hajdas, H. Henschel, H. D. Graf, G. G. Lichti, P. v. Neumannâ Cosel, A. Richter, and V. Schönfelder, â Influence of radiation damage on BGO scintillation properties,â Nucl. Instrum. Methods Phys. Res. A NIMAER --> 0168‐9002 --> 413, 50 â 58 ( 1998 ). 10.1016/S0168â 9002(98)00539â 7 | |
dc.identifier.citedreference | V. A. Gusev, I. N. Kupriyanov, V. D. Antsygin, Y. V. Vasiliev, V. N. Shlegel, G. N. Kuznetsov, N. V. Ivannikova, A. I. Korchagin, A. V. Lavrukhin, S. E. Petrov, and S. N. Fadeev, â Features of radiation damage of BGO crystals grown by the lowâ thermalâ gradient Czochralski technique,â Nucl. Instrum. Methods Phys. Res. A NIMAER --> 0168‐9002 --> 460, 457 â 464 ( 2001 ). 10.1016/S0168â 9002(00)01078â 0 | |
dc.identifier.citedreference | P. Kozma and P. Kozma, â Radiation resistivity of BGO crystals due to lowâ energy gammaâ rays,â Nucl. Instrum. Methods Phys. Res. A NIMAER --> 0168‐9002 --> 501, 499 â 504 ( 2003 ). 10.1016/S0168â 9002(03)00617â X | |
dc.identifier.citedreference | P. Lecoq, P. J. Li, and B. Rostaing, â BGO radiation damage effects: Optical absorption, thermoluminescence and thermoconductivity,â Nucl. Instrum. Methods Phys. Res. A NIMAER --> 0168‐9002 --> 300, 240 â 258 ( 1991 ). 10.1016/0168â 9002(91)90433â Q | |
dc.identifier.citedreference | K. C. Peng, R. S. Lu, K. Ueno, C. H. Wang, M. Z. Wang, F. I. Chou, Y. Y. Wei, and W. S. Hou, â Lowâ dose radiation damage and recovery of undoped BGO crystals,â Nucl. Instrum. Methods Phys. Res. A NIMAER --> 0168‐9002 --> 452, 252 â 255 ( 2000 ). 10.1016/S0168â 9002(00)00436â 8 | |
dc.identifier.citedreference | S. K. Sahu, K. C. Peng, H. C. Huang, C. H. Wang, Y. H. Chang, W. S. Hou, K. Ueno, F. I. Chou, and Y. Y. Wei, â Radiation hardness of undoped BGO crystals,â Nucl. Instrum. Methods Phys. Res. A NIMAER --> 0168‐9002 --> 388, 144 â 148 ( 1997 ). 10.1016/S0168â 9002(97)00333â 1 | |
dc.identifier.citedreference | L. E. Antonuk, â Electronic portal imaging devices: A review and historical perspective of contemporary technologies and research,â Phys. Med. Biol. PHMBA7 --> 0031‐9155 --> 47, R31 â R65 ( 2002 ). 10.1088/0031â 9155/47/2/401 | |
dc.identifier.citedreference | Y. Elâ Mohri, K. â W. Jee, L. E. Antonuk, M. Maolinbay, and Q. Zhao, â Determination of the detective quantum efficiency of a prototype, megavoltage indirect detection, active matrix flatâ panel imager,â Med. Phys. MPHYA6 --> 0094‐2405 --> 28, 2538 â 2550 ( 2001 ). 10.1118/1.1413516 | |
dc.identifier.citedreference | L. E. Antonuk, K. â W. Jee, Y. Elâ Mohri, M. Maolinbay, S. Nassif, X. Rong, Q. Zhao, J. H. Siewerdsen, R. A. Street, and K. S. Shah, â Strategies to improve the signal and noise performance of active matrix, flatâ panel imagers for diagnostic xâ ray applications,â Med. Phys. MPHYA6 --> 0094‐2405 --> 27, 289 â 306 ( 2000 ). 10.1118/1.598831 | |
dc.identifier.citedreference | Y. Elâ Mohri, L. E. Antonuk, Q. Zhao, Y. Wang, Y. Li, H. Du, and A. Sawant, â Performance of a high fill factor, indirect detection prototype flatâ panel imager for mammography,â Med. Phys. MPHYA6 --> 0094‐2405 --> 34, 315 â 327 ( 2007 ). 10.1118/1.2403967 | |
dc.identifier.citedreference | P. R. Granfors, R. Aufrichtig, G. E. Possin, B. W. Giambattista, Z. S. Huang, J. Liu, and B. Ma, â Performance of a 41 Ã 41 cm 2 amorphous silicon flat panel xâ ray detector designed for angiographic and R&F imaging applications,â Med. Phys. MPHYA6 --> 0094‐2405 --> 30, 2715 â 2726 ( 2003 ). 10.1118/1.1609151 | |
dc.identifier.citedreference | J. Pouliot, A. Baniâ Hashemi, J. Chen, M. Svatos, F. Ghelmansarai, M. Mitschke, M. Aubin, P. Xia, O. Morin, K. Bucci, M. Roach III, P. Hernandez, Z. Zheng, D. Hristov, and L. Verhey, â Lowâ dose megavoltage coneâ beam CT for radiation therapy,â Int. J. Radiat. Oncol., Biol., Phys. IOBPD3 --> 0360‐3016 --> 61, 552 â 560 ( 2005 ). 10.1016/j.ijrobp.2004.10.011 | |
dc.identifier.citedreference | O. Morin, J. Chen, M. Aubin, S. Bose, A. Gillis, M. Bucci, and J. Pouliot, â Dose calculation using megavoltage cone beam CT imaging,â Int. J. Radiat. Oncol., Biol., Phys. IOBPD3 --> 0360‐3016 --> 63, S62 â S63 ( 2005 ). 10.1016/j.ijrobp.2005.07.109 | |
dc.identifier.citedreference | O. Morin, A. Gillis, J. Chen, M. Aubin, M. K. Bucci, M. Roach III, and J. Pouliot, â Megavoltage coneâ beam CT: System description and clinical applications,â Med. Dosim. 0739‐0211 --> 31, 51 â 61 ( 2006 ). 10.1016/j.meddos.2005.12.009 | |
dc.identifier.citedreference | O. Morin, A. Gillis, M. Descovich, J. Chen, M. Aubin, J. Aubry, H. Chen, A. Gottschalk, P. Xia, and J. Pouliot, â Patient dose considerations for routine megavoltage coneâ beam CT imaging,â Med. Phys. MPHYA6 --> 0094‐2405 --> 34, 1819 â 1827 ( 2007 ). 10.1118/1.2722470 | |
dc.identifier.citedreference | K. M. Langen, S. L. Meeks, D. O. Poole, T. H. Wagner, T. R. Willoughby, P. A. Kupelian, K. J. Ruchala, J. Haimerl, and G. H. Olivera, â The use of megavoltage CT (MVCT) images for dose recomputations,â Phys. Med. Biol. PHMBA7 --> 0031‐9155 --> 50, 4259 â 4276 ( 2005 ). 10.1088/0031â 9155/50/18/002 | |
dc.identifier.citedreference | E. C. Ford, J. Chang, K. Mueller, K. Sidhu, D. Todor, G. Mageras, E. Yorke, C. C. Ling, and H. Amols, â Coneâ beam CT with megavoltage beams and an amorphous silicon electronic portal imaging device: Potential for verification of radiotherapy of lung cancer,â Med. Phys. MPHYA6 --> 0094‐2405 --> 29, 2913 â 2924 ( 2002 ). 10.1118/1.1517614 | |
dc.identifier.citedreference | J. Sillanpaa, J. Chang, G. Mageras, H. Riem, E. Ford, D. Todor, C. C. Ling, and H. Amols, â Developments in megavoltage cone beam CT with an amorphous silicon EPID: Reduction of exposure and synchronization with respiratory gating,â Med. Phys. MPHYA6 --> 0094‐2405 --> 32, 819 â 829 ( 2005 ). 10.1118/1.1861522 | |
dc.identifier.citedreference | J. Sillanpaa, J. Chang, G. Mageras, E. Yorke, F. De Arruda, K. E. Rosenzweig, P. Munro, E. J. Seppi, J. M. Pavkovich, and H. Amols, â Lowâ dose megavoltage coneâ beam computed tomography for lung tumors using a highâ efficiency image receptor,â Med. Phys. MPHYA6 --> 0094‐2405 --> 33, 3489 â 3497 ( 2006 ). 10.1118/1.2222075 | |
dc.identifier.citedreference | M. Descovich, O. Morin, J. F. Aubry, M. Aubin, J. Chen, A. Baniâ Hashemi, and J. Pouliot, â Characteristics of megavoltage coneâ beam digital tomosynthesis,â Med. Phys. MPHYA6 --> 0094‐2405 --> 35, 1310 â 1316 ( 2008 ). 10.1118/1.2868763 | |
dc.identifier.citedreference | G. Pang, A. Baniâ Hashemi, P. Au, P. F. O’Brien, J. A. Rowlands, G. Morton, T. Lim, P. Cheung, and A. Loblaw, â Megavoltage cone beam digital tomosynthesis (MVâ CBDT) for imageâ guided radiotherapy: A clinical investigational system,â Phys. Med. Biol. PHMBA7 --> 0031‐9155 --> 53, 999 â 1013 ( 2008 ). 10.1088/0031â 9155/53/4/012 | |
dc.identifier.citedreference | J. A. Purdy, â 3â D radiation treatment planning: A new era,â Front. Radiat. Ther. Oncol. FRTOA7 --> 0071‐9676 --> 29, 1 â 16 ( 1996 ). | |
dc.identifier.citedreference | T. Bortfeld, â IMRT: A review and preview,â Phys. Med. Biol. PHMBA7 --> 0031‐9155 --> 51, R363 â R379 ( 2006 ). 10.1088/0031â 9155/51/13/R21 | |
dc.identifier.citedreference | T. R. Mackie, J. Kapatoes, K. Ruchala, W. Lu, C. Wu, G. Olivera, L. Forrest, W. Tome, J. Welsh, R. Jeraj, P. Harari, P. Reckwerdt, B. Paliwal, M. Ritter, H. Keller, J. Fowler, and M. Mehta, â Image guidance for precise conformal radiotherapy,â Int. J. Radiat. Oncol., Biol., Phys. IOBPD3 --> 0360‐3016 --> 56, 89 â 105 ( 2003 ). 10.1016/S0360â 3016(03)00090â 7 | |
dc.identifier.citedreference | B. A. Groh, J. H. Siewerdsen, D. G. Drake, J. W. Wong, and D. A. Jaffray, â A performance comparison of flatâ panel imagerâ based MV and kV coneâ beam CT,â Med. Phys. MPHYA6 --> 0094‐2405 --> 29, 967 â 975 ( 2002 ). 10.1118/1.1477234 | |
dc.identifier.citedreference | R. K. Swank, â Absorption and noise in xâ ray phosphors,â J. Appl. Phys. JAPIAU --> 0021‐8979 --> 44, 4199 â 4203 ( 1973 ). 10.1063/1.1662918 | |
dc.owningcollname | Interdisciplinary and Peer-Reviewed |
Files in this item
Remediation of Harmful Language
The University of Michigan Library aims to describe its collections in a way that respects the people and communities who create, use, and are represented in them. We encourage you to Contact Us anonymously if you encounter harmful or problematic language in catalog records or finding aids. More information about our policies and practices is available at Remediation of Harmful Language.
Accessibility
If you are unable to use this file in its current format, please select the Contact Us link and we can modify it to make it more accessible to you.