Inclusion of organ deformation in dose calculations
dc.contributor.author | Brock, K. K. | |
dc.contributor.author | McShan, D. L. | |
dc.contributor.author | Ten Haken, R. K. | |
dc.contributor.author | Hollister, S. J. | |
dc.contributor.author | Dawson, L. A. | |
dc.contributor.author | Balter, J. M. | |
dc.date.accessioned | 2017-01-06T20:50:32Z | |
dc.date.available | 2017-01-06T20:50:32Z | |
dc.date.issued | 2003-03 | |
dc.identifier.citation | Brock, K. K.; McShan, D. L.; Ten Haken, R. K.; Hollister, S. J.; Dawson, L. A.; Balter, J. M. (2003). "Inclusion of organ deformation in dose calculations." Medical Physics 30(3): 290-295. | |
dc.identifier.issn | 0094-2405 | |
dc.identifier.issn | 2473-4209 | |
dc.identifier.uri | https://hdl.handle.net/2027.42/135079 | |
dc.publisher | Wiley Periodicals, Inc. | |
dc.publisher | American Association of Physicists in Medicine | |
dc.subject.other | computerised tomography | |
dc.subject.other | Tissues | |
dc.subject.other | organ motion | |
dc.subject.other | organ deformation | |
dc.subject.other | dose calculations | |
dc.subject.other | mechanical modeling | |
dc.subject.other | Movement | |
dc.subject.other | Locomotion | |
dc.subject.other | Dosimetry/exposure assessment | |
dc.subject.other | Computed radiography | |
dc.subject.other | Hemodynamics | |
dc.subject.other | Pneumodyamics, respiration | |
dc.subject.other | Mechanical and electrical properties of tissues and organs | |
dc.subject.other | General theory and mathematical aspects | |
dc.subject.other | Simulation | |
dc.subject.other | Finite‐element and Galerkin methods | |
dc.subject.other | biomechanics | |
dc.subject.other | tumours | |
dc.subject.other | pneumodynamics | |
dc.subject.other | radiation therapy | |
dc.subject.other | dosimetry | |
dc.subject.other | physiological models | |
dc.subject.other | Physicists | |
dc.subject.other | finite element analysis | |
dc.subject.other | Dosimetry | |
dc.subject.other | Cancer | |
dc.subject.other | Liver | |
dc.subject.other | Anatomy | |
dc.subject.other | Rigid body dynamics | |
dc.subject.other | Finite element methods | |
dc.subject.other | Radiation therapy | |
dc.title | Inclusion of organ deformation in dose calculations | |
dc.type | Article | en_US |
dc.rights.robots | IndexNoFollow | |
dc.subject.hlbsecondlevel | Medicine (General) | |
dc.subject.hlbtoplevel | Health Sciences | |
dc.description.peerreviewed | Peer Reviewed | |
dc.contributor.affiliationum | Department of Radiation Oncology, University of Michigan, Ann Arbor, Michigan 48109 | |
dc.contributor.affiliationum | Department of Biomedical Engineering, University of Michigan, Ann Arbor, Michigan 48109 | |
dc.contributor.affiliationum | Department of Radiation Oncology, University of Michigan, Ann Arbor, Michigan 48109 | |
dc.description.bitstreamurl | http://deepblue.lib.umich.edu/bitstream/2027.42/135079/1/mp9039.pdf | |
dc.identifier.doi | 10.1118/1.1539039 | |
dc.identifier.source | Medical Physics | |
dc.identifier.citedreference | L. A. Dawson, D. Normelle, J. M. Balter, C. J. McGinn, T. S. Lawrence, and R. K. Ten Haken, “ Analysis of radiation induced liver disease using the Lyman NTCP model,” Int. J. Radiat. Oncol., Biol., Phys. IOBPD3 --> 53, 810 – 821 ( 2002 ). IOBPD3 --> 0360‐3016 | |
dc.identifier.citedreference | E. C. Ford, G. S. Mageras, E. Yorke, K. E. Rosenzweig, R. Wagman, and C. C. Ling, “ Evaluation of respiratory movement during gated radiotherapy using film and electronic portal imaging,” Int. J. Radiat. Oncol., Biol., Phys. IOBPD3 --> 52, 522 – 531 ( 2002 ). IOBPD3 --> 0360‐3016 | |
dc.identifier.citedreference | H. Shirato, S. Shimizu, K. Kitamura, T. Nishioka, K. Kagei, S. Hashimoto, H. Aoyama, T. Kunieda, N. Shinohara, H. Dosaka‐Akita, and K. Miyasaka, “ Four‐dimensional treatment planning and fluoroscopic real‐time tumor tracking radiotherapy for moving tumor,” Int. J. Radiat. Oncol., Biol., Phys. IOBPD3 --> 48, 435 – 442 ( 2000 ). IOBPD3 --> 0360‐3016 | |
dc.identifier.citedreference | L. A. Dawson, K. K. Brock, S. Kazanjian, D. Fitch, C. J. McGinn, T. S. Lawrence, R. K. Ten Haken, and J. Balter, “ The reproducibility of organ position using active breathing control (ABC) during liver radiotherapy,” Int. J. Radiat. Oncol., Biol., Phys. IOBPD3 --> 51, 1410 – 1421 ( 2001 ). IOBPD3 --> 0360‐3016 | |
dc.identifier.citedreference | S. A. Kruse, J. A. Smith, A. J. Lawrence, M. A. Dresner, A. Manduca, J. F. Greenleaf, and R. L. Ehman, “ Tissue characterization using magnetic resonance elastography: preliminary results,” Phys. Med. Biol. PHMBA7 --> 45, 1579 – 1590 ( 2000 ). PHMBA7 --> 0031‐9155 | |
dc.identifier.citedreference | K. K. Brock, S. J. Hollister, L. A. Dawson, and J. M. Balter, “ Technical Note: Creating a 4‐Dimensional model of the liver using finite element analysis,” Med. Phys. MPHYA6 --> 29, 1403 – 1405 ( 2002 ). MPHYA6 --> 0094‐2405 | |
dc.identifier.citedreference | C. R. Meyer, J. L. Boes, B. Kim, P. H. Bland, K. R. Zasadny, P. V. Kison, K. Koral, K. A. Frey, and R. L. Wahl, “ Demonstration of accuracy and clinical versatility of mutual information for automatic multimodality image fusion using affine and thin‐plate spline warped geometric deformations,” Med. Image Anal 3, 195 – 206 ( 1997 ). 1361‐8415 | |
dc.identifier.citedreference | G. J. Kutcher and C. Burman, “ Calculation of complication probability factor for nonuniform normal tissue irradiation: The effective volume method,” Int. J. Radiat. Oncol., Biol., Phys. IOBPD3 --> 16, 1623 – 1630 ( 1989 ). IOBPD3 --> 0360‐3016 | |
dc.identifier.citedreference | R. K. Ten Haken, M. K. Martel, M. L. Kessler, M. B. Hazuka, T. S. Lawrence, J. M. Robertson, A. T. Turrisi, and A. S. Lichter, “ Use of Veff and iso‐NTCP in the implementation of dose escalation protocols,” Int. J. Radiat. Oncol., Biol., Phys. IOBPD3 --> 27, 689 – 695 ( 1993 ). IOBPD3 --> 0360‐3016 | |
dc.identifier.citedreference | J. T. Lyman, “ Complication probability as assessed from dose‐volume histograms,” Radiat. Res. RAREAE --> 104, s13 – s19 ( 1985 ). RAREAE --> 0033‐7587 | |
dc.identifier.citedreference | H. D. Kubo and B. C. Hill, “ Respiration gated radiotherapy treatment: A technical study,” Phys. Med. Biol. PHMBA7 --> 41, 83 – 91 ( 1996 ). PHMBA7 --> 0031‐9155 | |
dc.identifier.citedreference | K. Kitamura et al., “ Registration accuracy and possible migration of internal fiducial gold marker implanted in prostate and liver treated with real‐time tumor‐tracking radiation therapy (RTRT),” Radiother. Oncol. RAONDT --> 62, 275 – 281 ( 2002 ). RAONDT --> 0167‐8140 | |
dc.identifier.citedreference | J. W. Wong, M. B. Sharpe, D. A. Jaffray, V. R. Kini, J. M. Robertson, J. S. Stromberg, and A. A. Martinez, “ The use of active breathing control (ABC) to reduce margin for breathing motion,” Int. J. Radiat. Oncol., Biol., Phys. IOBPD3 --> 44, 911 – 919 ( 1999 ). IOBPD3 --> 0360‐3016 | |
dc.identifier.citedreference | J. H. Killoran, H. K. Kooy, D. J. Gladstone, F. J. Welte, and C. J. Beard, “ A numerical simulation of organ motion and daily setup uncertainties: implications for radiation therapy,” Int. J. Radiat. Oncol., Biol., Phys. IOBPD3 --> 37, 213 – 221 ( 1997 ). IOBPD3 --> 0360‐3016 | |
dc.identifier.citedreference | G. S. Mageras, G. H. Kutcher, S. A. Leibel, M. J. Zelefsky, E. Melian, R. Mohan, and Z. Fuks, “ A method of incorporating organ motion uncertainties into three‐dimensional conformal treatment plans,” Int. J. Radiat. Oncol., Biol., Phys. IOBPD3 --> 35, 333 – 342 ( 1996 ). IOBPD3 --> 0360‐3016 | |
dc.identifier.citedreference | J. M. Balter, L. A. Dawson, S. Kazanjian, C. McGinn, K. K. Brock, T. S. Lawrence, and R. K. Ten Haken, “ Determination of ventilatory liver movement via radiographic evaluation of diaphragm position,” Int. J. Radiat. Oncol., Biol., Phys. IOBPD3 --> 51, 267 – 270 ( 2001 ). IOBPD3 --> 0360‐3016 | |
dc.identifier.citedreference | R. K. Ten Haken, J. M. Balter, L. H. Marsh, J. M. Robertson, and T. S. Lawrence, “ Potential benefits of eliminating planning target volume expansions for patient breathing in the treatment of liver tumors,” Int. J. Radiat. Oncol., Biol., Phys. IOBPD3 --> 38, 613 – 617 ( 1997 ). IOBPD3 --> 0360‐3016 | |
dc.identifier.citedreference | J. M. Balter, K. L. Lam, C. J. McGinn, T. S. Lawrence, and R. K. Ten Haken, “ Improvement of CT‐based treatment‐planning models of ab‐dominal targets using static exhale imaging,” Int. J. Radiat. Oncol., Biol., Phys. IOBPD3 --> 41, 939 – 943 ( 1998 ). IOBPD3 --> 0360‐3016 | |
dc.identifier.citedreference | A. E. Lujan, E. W. Larsen, J. M. Balter, and R. K. Ten Haken, “ A method for incorporating organ motion due to breathing into 3D dose calculations,” Med. Phys. MPHYA6 --> 26, 715 – 720 ( 1999 ). MPHYA6 --> 0094‐2405 | |
dc.identifier.citedreference | K. Miller, “ Constitutive modeling of abdominal organs,” J. Biomech. JBMCB5 --> 33, 367 – 373 ( 2000 ). JBMCB5 --> 0021‐9290 | |
dc.identifier.citedreference | J. W. Melvin, R. L. Stalnaker, and V. L. Roberts, “ Impact injury mechanisms in abdominal organs,” SAE Trans. SAETA5 --> 730968, 115 – 126 ( 1973 ). SAETA5 --> 0096‐736X | |
dc.identifier.citedreference | D. Yan and D. Lockman, “ Organ/patient geometric variation in external beam radiotherapy and its effects,” Med. Phys. MPHYA6 --> 28, 593 – 602 ( 2001 ). MPHYA6 --> 0094‐2405 | |
dc.owningcollname | Interdisciplinary and Peer-Reviewed |
Files in this item
Remediation of Harmful Language
The University of Michigan Library aims to describe library materials in a way that respects the people and communities who create, use, and are represented in our collections. Report harmful or offensive language in catalog records, finding aids, or elsewhere in our collections anonymously through our metadata feedback form. More information at Remediation of Harmful Language.
Accessibility
If you are unable to use this file in its current format, please select the Contact Us link and we can modify it to make it more accessible to you.