Show simple item record

Improvement of computerized mass detection on mammograms: Fusion of twoâ view information

dc.contributor.authorPaquerault, Sophie
dc.contributor.authorPetrick, Nicholas
dc.contributor.authorChan, Heang‐ping
dc.contributor.authorSahiner, Berkman
dc.contributor.authorHelvie, Mark A.
dc.date.accessioned2017-01-06T20:50:33Z
dc.date.available2017-01-06T20:50:33Z
dc.date.issued2002-02
dc.identifier.citationPaquerault, Sophie; Petrick, Nicholas; Chan, Heang‐ping ; Sahiner, Berkman; Helvie, Mark A. (2002). "Improvement of computerized mass detection on mammograms: Fusion of twoâ view information." Medical Physics 29(2): 238-247.
dc.identifier.issn0094-2405
dc.identifier.issn2473-4209
dc.identifier.urihttps://hdl.handle.net/2027.42/135080
dc.publisherAmerican Association of Physicists in Medicine
dc.publisherWiley Periodicals, Inc.
dc.subject.otherMammography
dc.subject.othercomputerâ aided diagnosis
dc.subject.othermammography
dc.subject.othermass detection
dc.subject.otherclassification
dc.subject.otherfusion of information
dc.subject.otherMammography
dc.subject.otherImage quality
dc.subject.othermedical image processing
dc.subject.othermammography
dc.subject.otherdiagnostic radiography
dc.subject.otherimage classification
dc.subject.otherimage matching
dc.subject.otherFilm mammography
dc.subject.otherInformation integration
dc.subject.otherImage detection systems
dc.subject.otherComputer aided diagnosis
dc.subject.otherRadiologists
dc.subject.otherMedical imaging
dc.subject.otherData fusion
dc.subject.otherPhysicists
dc.titleImprovement of computerized mass detection on mammograms: Fusion of twoâ view information
dc.typeArticleen_US
dc.rights.robotsIndexNoFollow
dc.subject.hlbsecondlevelMedicine (General)
dc.subject.hlbtoplevelHealth Sciences
dc.description.peerreviewedPeer Reviewed
dc.contributor.affiliationumDepartment of Radiology, University of Michigan, Ann Arbor, Michigan 48109â 0030
dc.description.bitstreamurlhttp://deepblue.lib.umich.edu/bitstream/2027.42/135080/1/mp6098.pdf
dc.identifier.doi10.1118/1.1446098
dc.identifier.sourceMedical Physics
dc.identifier.citedreferenceH. P. Chan, K. Doi, C. J. Vyborny, R. A. Schmidt, C. E. Metz, K. L. Lam, T. Ogura, Y. Wu, and H. MacMahon, â Improvement in radiologists’ detection of clustered microcalcifications on mammograms. The potential of computerâ aided diagnosis,â Invest. Radiol. INVRAV --> 25, 1102 â 1110 ( 1990 ). INVRAV --> 0020â 9996
dc.identifier.citedreferenceL. J. Warren Burhenne, S. A. Wood, C. J. D’Orsi, S. A. Feig, D. B. Kopans, K. F. O’Shaughnessy, E. A. Sickles, L. Tabar, C. J. Vyborny, and R. A. Castellino, â Potential contribution of computerâ aided detection to the sensitivity of screening mammography,â Radiology RADLAX --> 215, 554 â 562 ( 2000 ). RADLAX --> 0033â 8419
dc.identifier.citedreferenceF. F. Yin, M. L. Giger, K. Doi, C. E. Metz, C. J. Vyborny, and R. A. Schmidt, â Computerized detection of masses in digital mammograms: Analysis of bilateral subtraction images,â Med. Phys. MPHYA6 --> 18, 955 â 963 ( 1991 ). MPHYA6 --> 0094â 2405
dc.identifier.citedreferenceL. M. Hadjiiski, B. Sahiner, H. P. Chan, N. Petrick, M. A. Helvie, and M. Gurcan, â Analysis of temporal change of mammographic features for computerâ aided characterization of malignant and benign masses,â Proc. SPIE PSISDG --> 4322, 661 â 666 ( 2001 ). PSISDG --> 0277â 786X
dc.identifier.citedreferenceL. M. Hadjiiski, H. P. Chan, B. Sahiner, N. Petrick, and M. A. Helvie, â Automated registration of breast lesions in temporal pairs of mammograms for interval change analysisâ local affine transformation for improved localization,â Med. Phys. MPHYA6 --> 28, 1070 â 1079 ( 2001 ). MPHYA6 --> 0094â 2405
dc.identifier.citedreferenceL. M. Hadjiiski, B. Sahiner, H. P. Chan, N. Petrick, M. A. Helvie, and M. N. Gurcan, â Analysis of temporal change of mammographic features: Computerâ aided classification of malignant and benign breast masses,â Med. Phys. MPHYA6 --> 28, 2309 â 2317 ( 2001 ). MPHYA6 --> 0094â 2405
dc.identifier.citedreferenceY. Kita, R. P. Highnam, and J. M. Brady, â Correspondence between different view breast x rays using curved epipolar lines,â Comput. Vis. Image Underst. CVIUF4 --> 83, 38 â 56 ( 2001 ). CVIUF4 --> 1077â 3142
dc.identifier.citedreferenceW. F. Good, B. Zheng, Y. H. Chang, Z. H. Wang, G. S. Maitz, and D. Gur, â Multiâ image CAD employing features derived from ipsilateral mammographic views,â Proc. SPIE PSISDG --> 3661, 474 â 485 ( 1999 ). PSISDG --> 0277â 786X
dc.identifier.citedreferenceY. H. Chang, W. F. Good, J. H. Sumkin, B. Zheng, and D. Gur, â Computerized localization of breast lesions from two viewsâ An experimental comparison of two methods,â Invest. Radiol. INVRAV --> 34, 585 â 588 ( 1999 ). INVRAV --> 0020â 9996
dc.identifier.citedreferenceS. S. Gopal, H. P. Chan, T. E. Wilson, M. A. Helvie, N. Petrick, and B. Sahiner, â A regional registration technique for automated interval change analysis of breast lesions on mammograms,â Med. Phys. MPHYA6 --> 26, 2669 â 2679 ( 1999 ). MPHYA6 --> 0094â 2405
dc.identifier.citedreferenceS. Paquerault, B. Sahiner, N. Petrick, L. M. Hadjiiski, M. N. Gurcan, C. Zhou, and M. A. Helvie, â Prediction of object location in different views using geometrical models,â Proceedings of the 5th International Workshop on Digital Mammography, Toronto, Canada, 11â 14 June 2000, Digital Mammography, Madison, WI (Medical Physics Publishing), pp. 748â 755.
dc.identifier.citedreferenceS. Paquerault, N. Petrick, H. P. Chan, B. Sahiner, and A. Y. Dolney, â Improvement of mammographic lesion detection by fusion of information from different views,â Proc. SPIE PSISDG --> 4322, 1883 â 1889 ( 2001 ). PSISDG --> 0277â 786X
dc.identifier.citedreferenceA. R. Morton, H. P. Chan, and M. M. Goodsitt, â Automated modelâ guided breast segmentation algorithm,â Med. Phys. MPHYA6 --> 23, 1107 â 1108 ( 1996 ). MPHYA6 --> 0094â 2405
dc.identifier.citedreferenceC. Zhou, H. P. Chan, N. Petrick, M. M. Goodsitt, C. Paramagul, and L. M. Hadjiiski, â Computerized image analysis: breast segmentation and nipple identification on mammograms,â Proceedings of the Chicago 2000â World Congress on Medical Physics and Biomedical Engineering, Chicago, Illinois, 23â 28 July, 2000, Paper No. THâ Aa201â 04.
dc.identifier.citedreferenceN. Petrick, H. P. Chan, D. Wei, B. Sahiner, M. A. Helvie, and D. D. Adler, â Automated detection of breast masses on mammograms using adaptive contrast enhancement and texture classification,â Med. Phys. MPHYA6 --> 23, 1685 â 1696 ( 1996 ). MPHYA6 --> 0094â 2405
dc.identifier.citedreferenceN. Petrick, H. P. Chan, B. Sahiner, and D. Wei, â An adaptive densityâ weighted contrast enhancement filter for mammographic breast mass detection,â IEEE Trans. Med. Imaging ITMID4 --> 15, 59 â 67 ( 1996 ). ITMID4 --> 0278â 0062
dc.identifier.citedreferenceN. Petrick, H. P. Chan, B. Sahiner, and M. A. Helvie, â Combined adaptive enhancement and regionâ growing segmentation of breast masses on digitized mammograms,â Med. Phys. MPHYA6 --> 26, 1642 â 1654 ( 1999 ). MPHYA6 --> 0094â 2405
dc.identifier.citedreferenceN. Petrick, B. Sahiner, H. P. Chan, M. A. Helvie, and S. Paquerault, â Preclinical evaluation of a CAD algorithm for early detection of breast cancer,â Proceedings of the 5th International Workshop on Digital Mammography, Toronto, Canada, 11â 14 June 2000, Digital Mammography, Madison, WI (Medical Physics Publishing), pp. 328â 333.
dc.identifier.citedreferenceR. M. Haralick, K. Shanmugam, and I. Dinstein, â Texture features for image classification,â IEEE Trans. Syst. Man Cybern. ISYMAW --> SMCâ 3, 610 â 621 ( 1973 ). ISYMAW -->
dc.identifier.citedreferenceR. M. Haralick, â Statistical image texture analysis,â in Handbook of Pattern Recognition and Image Processing (Academic, New York, 1986).
dc.identifier.citedreferenceP. C. Bunch, J. F. Hamilton, G. K. Sanderson, and A. H. Simmons, â A free response approach to the measurement and characterization of radiographic observer performance,â J. Appl. Photogr. Eng. JAPEDL --> 4, 166 â 171 ( 1978 ). JAPEDL --> 0098â 7298
dc.identifier.citedreferenceA. Kandel, Fuzzy Techniques in Pattern Recognition (Wiley, New York, 1982).
dc.identifier.citedreferenceB. Sahiner, H. P. Chan, N. Petrick, D. Wei, M. A. Helvie, D. D. Adler, and M. M. Goodsitt, â Classification of mass and normal breast tissue: An artificial neural network with morphological features,â Proc. World Cong. Neural Net. II, 1995, pp. 876â 879.
dc.identifier.citedreferenceG. M. te Brake, N. Karssemeijer, and J. H. C. L. Hendriks, â An automatic method to discriminate malignant masses from normal tissue in digital mammograms,â Phys. Med. Biol. PHMBA7 --> 45, 2843 â 2857 ( 2000 ). PHMBA7 --> 0031â 9155
dc.identifier.citedreferenceL. Tabar et al., â Reduction in mortality from breast cancer after mass screening with mammography,â Lancet LANCAO --> 1, 829 â 832 ( 1985 ). LANCAO --> 0140â 6736
dc.identifier.citedreferenceH. C. Zuckerman, â The role of mammography in the diagnosis of breast cancer.â in: Breast Cancer Diagnosis and Treatment, edited by I. M. Ariel and J. B. Cleary (McGrawâ Hill, New York, 1987), pp. 152â 172.
dc.identifier.citedreferenceL. W. Bassett, D. H. Bunnell, R. Jahanshahi, R. H. Gold, R. D. Arndt, and J. Linsman, â Breast cancer detection: one versus two views,â Radiology RADLAX --> 165, 95 â 97 ( 1987 ). RADLAX --> 0033â 8419
dc.identifier.citedreferenceE. Thurfjell, â Mammography screening: One versus two views and independent double reading,â Acta Radiol. ACRAE3 --> 35, 345 â 350 ( 1994 ). ACRAE3 --> 0284â 1851
dc.identifier.citedreferenceR. G. Blanks, M. G. Wallis, and R. M. Givenâ Wilson, â Observer variability in cancer detection during routine repeat (incident) mammographic screening in a study of two versus one view mammography,â J. Med. Screen 6, 152 â 158 ( 1999 ). 0969â 1413
dc.identifier.citedreferenceE. D. C. Anderson, B. B. Muir, J. S. Walsh, and A. E. Kirkpatrick, â The efficacy of double reading mammograms in breast screening,â Clin. Radiol. CLRAAG --> 49, 248 â 251 ( 1994 ). CLRAAG --> 0009â 9260
dc.identifier.citedreferenceE. L. Thurfjell, K. A. Lernevall, and A. A. S. Taube, â Benefit of independent double reading in a populationâ based mammography screening program,â Radiology RADLAX --> 191, 241 â 244 ( 1994 ). RADLAX --> 0033â 8419
dc.identifier.citedreferenceW. P. Kegelmeyer, J. M. Pruneda, P. D. Bourland, A. Hillis, M. W. Riggs, and M. L. Nipper, â Computerâ aided mammographic screening for spiculated lesions,â Radiology RADLAX --> 191, 331 â 337 ( 1994 ). RADLAX --> 0033â 8419
dc.identifier.citedreferenceB. Sahiner, N. Petrick, H. P. Chan, S. Paquerault, M. A. Helvie, and L. M. Hadjiiski, â Recognition of lesion correspondence on two mammographic viewsâ A new method of falseâ positive reduction for computerized mass detection,â Proc. SPIE PSISDG --> 4322, 649 â 655 ( 2001 ). PSISDG --> 0277â 786X
dc.owningcollnameInterdisciplinary and Peer-Reviewed


Files in this item

Show simple item record

Remediation of Harmful Language

The University of Michigan Library aims to describe library materials in a way that respects the people and communities who create, use, and are represented in our collections. Report harmful or offensive language in catalog records, finding aids, or elsewhere in our collections anonymously through our metadata feedback form. More information at Remediation of Harmful Language.

Accessibility

If you are unable to use this file in its current format, please select the Contact Us link and we can modify it to make it more accessible to you.