Show simple item record

Multiscale bilateral filtering for improving image quality in digital breast tomosynthesis

dc.contributor.authorLu, Yao
dc.contributor.authorChan, Heang‐ping
dc.contributor.authorWei, Jun
dc.contributor.authorHadjiiski, Lubomir M.
dc.contributor.authorSamala, Ravi K.
dc.date.accessioned2017-01-06T20:51:04Z
dc.date.available2017-01-06T20:51:04Z
dc.date.issued2015-01
dc.identifier.citationLu, Yao; Chan, Heang‐ping ; Wei, Jun; Hadjiiski, Lubomir M.; Samala, Ravi K. (2015). "Multiscale bilateral filtering for improving image quality in digital breast tomosynthesis." Medical Physics 42(1): 182-195.
dc.identifier.issn0094-2405
dc.identifier.issn2473-4209
dc.identifier.urihttps://hdl.handle.net/2027.42/135115
dc.publisherAmerican Association of Physicists in Medicine
dc.publisherWiley Periodicals, Inc.
dc.subject.otherDigital mammography
dc.subject.otherNumerical approximation and analysis
dc.subject.otherReconstruction
dc.subject.otherContrast
dc.subject.otherArtifacts and distortion
dc.subject.otherBiological material, e.g. blood, urine; Haemocytometers
dc.subject.otherDigital computing or data processing equipment or methods, specially adapted for specific applications
dc.subject.otheriterative reconstruction
dc.subject.othermicrocalcification
dc.subject.otherOptical microcavities
dc.subject.otherImage reconstruction
dc.subject.otherMedical image noise
dc.subject.otherMedical image reconstruction
dc.subject.otherMonte Carlo methods
dc.subject.otherTissues
dc.subject.otherMedical image contrast
dc.subject.otherMedical image artifacts
dc.subject.otherbiological organs
dc.subject.otherregularization method
dc.subject.othermultiscale decomposition
dc.subject.otherbilateral filtering
dc.subject.otherdigital beast tomosynthesis
dc.subject.otherfiltering theory
dc.subject.otherimage reconstruction
dc.subject.otheriterative methods
dc.subject.othermammography
dc.subject.othermedical image processing
dc.subject.otherphantoms
dc.subject.otherImage data processing or generation, in general
dc.titleMultiscale bilateral filtering for improving image quality in digital breast tomosynthesis
dc.typeArticleen_US
dc.rights.robotsIndexNoFollow
dc.subject.hlbsecondlevelMedicine (General)
dc.subject.hlbtoplevelHealth Sciences
dc.description.peerreviewedPeer Reviewed
dc.contributor.affiliationumDepartment of Radiology, University of Michigan, Ann Arbor, Michigan 48109
dc.description.bitstreamurlhttp://deepblue.lib.umich.edu/bitstream/2027.42/135115/1/mp3283.pdf
dc.identifier.doi10.1118/1.4903283
dc.identifier.sourceMedical Physics
dc.identifier.citedreferenceA. Kak and M. Slaney, Principle of Computerized Tomographic Imaging ( IEEE, 1988 ).
dc.identifier.citedreferenceM. L. Spangler, M. L. Zuley, J. H. Sumkin, G. Abrams, M. A. Ganott, C. Hakim, R. Perrin, D. M. Chough, R. Shah, and D. Gur, â Detection and classification of calcifications on digital breast tomosynthesis and 2D digital mammography: A comparison,â Am. J. Roentgenol. 196, 320 â 324 ( 2011 ). 10.2214/AJR.10.4656
dc.identifier.citedreferenceT. M. Svahn, D. P. Chakraborty, D. Ikeda, S. Zackrisson, Y. Do, S. Mattsson, and I. Andersson, â Breast tomosynthesis and digital mammography: A comparison of diagnostic accuracy,â Br. J. Radiol. 85, E1074 â E1082 ( 2012 ). 10.1259/bjr/53282892
dc.identifier.citedreferenceM. G. Wallis, E. Moa, F. Zanca, K. Leifland, and M. Danielsson, â Twoâ view and singleâ view tomosynthesis versus fullâ field digital mammography: Highâ resolution xâ ray imaging observer study,â Radiology 262, 788 â 796 ( 2012 ). 10.1148/radiol.11103514
dc.identifier.citedreferenceE. A. Rafferty, J. M. Park, L. E. Philpotts, S. P. Poplack, J. H. Sumkin, E. F. Halpern, and L. T. Niklason, â Assessing radiologist performance using combined digital mammography and breast tomosynthesis compared with digital mammography alone: Results of a multicenter, multireader trial,â Radiology 266, 104 â 113 ( 2013 ). 10.1148/radiol.12120674
dc.identifier.citedreferenceS. L. Rose, A. L. Tidwell, L. J. Bujnoch, A. C. Kushwaha, A. S. Nordmann, and R. Sexton, â Implementation of breast tomosynthesis in a routine screening practice: An observational study,â Am. J. Roentgenol. 200, 1401 â 1408 ( 2013 ). 10.2214/AJR.12.9672
dc.identifier.citedreferenceP. Skaane, A. I. Bandos, R. Gullien, E. B. Eben, U. Ekseth, U. Haakenaasen, M. Izadi, I. N. Jebsen, G. Jahr, and M. Krager, â Comparison of digital mammography alone and digital mammography plus tomosynthesis in a populationâ based screening program,â Radiology 267, 47 â 56 ( 2013 ). 10.1148/radiol.12121373
dc.identifier.citedreferenceR. C. Gonzalez and R. E. Woods, Digital image processing, 2nd ed. ( Prenticeâ Hall, 2002 ).
dc.identifier.citedreferenceP. Perona and J. Malik, â Scaleâ space and edge detection using anisotropic diffusion,â IEEE Trans. Pattern Anal. Mach. Intell. 12, 629 â 639 ( 1990 ). 10.1109/34.56205
dc.identifier.citedreferenceL. I. Rudin, S. Osher, and E. Fatemi, â Nonlinear total variation based noise removal algorithms,â Phys. D (Amsterdam, Neth.) 60, 259 â 268 ( 1992 ). 10.1016/0167â 2789(92)90242â f
dc.identifier.citedreferenceM. Black, G. Sapiro, D. Marimont, and D. Heeger, â Robust anisotropic diffusion,â IEEE Trans. Image Process. 7, 421 â 432 ( 1998 ). 10.1109/83.661192
dc.identifier.citedreferenceD. Barash and D. Comaniciu, â A common framework for nonlinear diffusion, adaptive smoothing, bilateral filtering and mean shift,â Image and Vision Comput. 22, 73 â 81 ( 2004 ). 10.1016/j.imavis.2003.08.005
dc.identifier.citedreferenceB. Zhang and J. P. Allebach, â Adaptive bilateral filter for sharpness enhancement and noise removal,â IEEE Trans. Image Process. 17, 664 â 678 ( 2008 ). 10.1109/tip.2008.919949
dc.identifier.citedreferenceE. Y. Sidky, I. S. Reiser, R. Nishikawa, and X. C. Pan, â Image reconstruction in digital breast tomosynthesis by total variation minimization,â Proc. SPIE 6510, U1110 â U1115 ( 2007 ). 10.1117/12.713663
dc.identifier.citedreferenceI. Kastanis, S. Arridge, A. Stewart, S. Gunn, C. Ullberg, and T. Francke, â 3D digital breast tomosynthesis using total variation regularization,â Digital Mammography, IWDM 2008â Lecture Notes in Computer Science Vol. 5116 ( Springer, Berlin, 2010 ), pp. 621 â 627.
dc.identifier.citedreferenceE. Y. Sidky, X. Pan, I. Reiser, R. M. Nishikawa, R. H. Moore, and D. B. Kopans, â Enhanced imaging of microcalcifications in digital breast tomosynthesis through improved imageâ reconstruction algorithms,â Med. Phys. 36, 4920 â 4932 ( 2009 ). 10.1118/1.3232211
dc.identifier.citedreferenceJ. W. Garrett, W. I. Madison, J. Tang, E. S. Burnside, J. B. Garrett, and G.â H. Chen, â Dose reduction in digital breast tomosynthesis with prior image constrained compressed sensing (PICCS),â in RSNA Program Book ( RSNA, Chicago, 2012 ).
dc.identifier.citedreferenceY. Lu, H.â P. Chan, J. Wei, and L. M. Hadjiiski, â Selectiveâ diffusion regularization for enhancement of microcalcifications in digital breast tomosynthesis reconstruction,â Med. Phys. 37, 6003 â 6014 ( 2010 ). 10.1118/1.3505851
dc.identifier.citedreferenceY. Lu, H.â P. Chan, J. A. Fessler, L. Hadjiiski, J. Wei, and M. M. Goodsitt, â Adaptive diffusion regularization for enhancement of microcalcifications in digital breast tomosynthesis (DBT) reconstruction,â Proc. SPIE 7961, 796117â 1 â 796117â 9 ( 2011 ). 10.1117/12.878096
dc.identifier.citedreferenceA. K. Jerebko, M. Kowarschik, and T. Mertelmeier, â Regularization parameter selection in maximum a posteriori iterative reconstruction for digital breast tomosynthesis,â Digital Mammography, IWDM2010â Lecture Notes in Computer Science Vol. 6136 ( Springer, Berlin, 2010 ), pp. 548 â 555.
dc.identifier.citedreferenceM. Das, H. C. Gifford, J. M. O’connor, and S. J. Glick, â Penalized maximum likelihood reconstruction for improved microcalcification detection in breast tomosynthesis,â IEEE Trans. Med. Imaging 30, 904 â 914 ( 2011 ). 10.1109/TMI.2010.2089694
dc.identifier.citedreferenceY. Lu, H.â P. Chan, J. Wei, L. M. Hadjiiski, and C. Zhou, â Multiscale regularized reconstruction for enhancing microcalcification in digital breast tomosynthesis,â Proc. SPIE 8313, 831322â 1 â 831322â 9 ( 2012 ). 10.1117/12.912573
dc.identifier.citedreferenceY. Lu, H.â P. Chan, J. Wei, R. K. Samala, L. Hadjiiski, and P. L. Carson, â Multiscale bilateral regularization in digital breast tomosynthesis (DBT),â in RSNA Program Book SSE22 ( RSNA, Chicago, 2012 ).
dc.identifier.citedreferenceY. Zhang, H.â P. Chan, B. Sahiner, J. Wei, M. M. Goodsitt, L. M. Hadjiiski, J. Ge, and C. Zhou, â A comparative study of limitedâ angle coneâ beam reconstruction methods for breast tomosynthesis,â Med. Phys. 33, 3781 â 3795 ( 2006 ). 10.1118/1.2237543
dc.identifier.citedreferenceR. L. Siddon, â Fast calculation of the exact radiological path for a threeâ dimensional CT array,â Med. Phys. 12, 252 â 255 ( 1985 ). 10.1118/1.595715
dc.identifier.citedreferenceT. Wu, R. H. Moore, E. A. Rafferty, and D. B. Kopans, â A comparison of reconstruction algorithms for breast tomosynthesis,â Med. Phys. 31, 2636 â 2647 ( 2004 ). 10.1118/1.1786692
dc.identifier.citedreferenceM. Jiang and G. Wang, â Convergence of the simultaneous algebraic reconstruction technique (SART),â IEEE Trans. Image Process. 12, 957 â 961 ( 2003 ). 10.1109/tip.2003.815295
dc.identifier.citedreferenceP. J. Burt and E. H. Adelson, â The Laplacian pyramid as a compact image code,â IEEE Trans. Commun. 31, 337 â 345 ( 1983 ). 10.1109/tcom.1983.1095851
dc.identifier.citedreferenceH.â P. Chan, S. C. B. Lo, L. T. Niklason, D. M. Ikeda, and K. L. Lam, â Image compression in digital mammography: Effects on computerized detection of subtle microcalcifications,â Med. Phys. 23, 1325 â 1336 ( 1996 ). 10.1118/1.597871
dc.identifier.citedreferenceS. Dippel, M. Stahl, R. Wiemker, and T. Blaffert, â Multiscale constrast enhancement for radiographies: Laplacian pyramid versus fast wavelet transform,â IEEE Trans. Med. Imaging 21, 343 â 353 ( 2002 ). 10.1109/TMI.2002.1000258
dc.identifier.citedreferenceJ. Wei, B. Sahiner, L. M. Hadjiiski, H.â P. Chan, N. Petrick, M. A. Helvie, M. A. Roubidoux, J. Ge, and C. Zhou, â Computer aided detection of breast masses on full field digital mammograms,â Med. Phys. 32, 2827 â 2838 ( 2005 ). 10.1118/1.1997327
dc.identifier.citedreferenceA. S. Saad, â Simultaneous speckle reduction and contrast enhancement for ultrasound images: Wavelet versus Laplacian pyramid,â Pattern Recognit. Image Anal. 18, 63 â 70 ( 2008 ). 10.1134/S1054661808010082
dc.identifier.citedreferenceX. Liu, J. Tang, S. Xiong, Z. Feng, and Z. Wang, â A multiscale contrast enhancement algorithm for breast cancer detection using Laplacian Pyramid,â in Proceedings of International Conference on Information and Automation ( IEEE, New York, 2009 ), p. 1167 â 1171.
dc.identifier.citedreferenceC. Tomasi and R. Manduchi, â Bilateral filtering for gray and color images,â in Proceedings of Sixth International Conference on Computer Vision ( IEEE, New York, 1998 ), p. 839 â 846. 10.1109/ICCV.1998.710815
dc.identifier.citedreferenceS. M. Smith and J. M. Brady, â SUSANâ A new approach to low level image processing,â Int. J. Comput. Vision 23, 45 â 78 ( 1997 ). 10.1023/A:1007963824710
dc.identifier.citedreferenceN. Sochen, R. Kimmel, and R. Malladi, â A general framework for low level vision,â IEEE Trans. Image Process. 7, 310 â 318 ( 1998 ). 10.1109/83.661181
dc.identifier.citedreferenceJ. Van de Weijer and R. Van den Boomgaard, â Local mode filtering,â in Proceedings of Computer Vision and Pattern Recognition ( IEEE, New York, 2001 ), Vol. 2, p. 428 â 433.
dc.identifier.citedreferenceM. Elad, â On the origin of the bilateral filter and ways to improve it,â IEEE Trans. Image Process. 11, 1141 â 1151 ( 2002 ). 10.1109/TIP.2002.801126
dc.identifier.citedreferenceD. Barash, â Fundamental relationship between bilateral filtering, adaptive smoothing, and the nonlinear diffusion equation,â IEEE Trans. Pattern Anal. Mach. Intell. 24, 844 â 847 ( 2002 ). 10.1109/tpami.2002.1008390
dc.identifier.citedreferenceJ. Chen, S. Paris, and F. Durand, â Realâ time edgeâ aware image processing with the bilateral grid,â ACM Trans. Graphics 26, 103 (pp. 1â 10) ( 2007 ). 10.1145/1276377.1276506
dc.identifier.citedreferenceR. Fattal, M. Agrawala, and S. Rusinkiewicz, â Multiscale shape and detail enhancement from multiâ light image collections,â ACM Trans.Graphics 26, 51 (pp. 1â 9) ( 2007 ). 10.1145/1276377.1276441
dc.identifier.citedreferenceM. Zhang and B. K. Gunturk, â Multiresolution bilateral filtering for image denoising,â IEEE Trans.Image Process. 17, 2324 â 2333 ( 2008 ). 10.1109/tip.2008.2006658
dc.identifier.citedreferenceH.â P. Chan, M. M. Goodsitt, M. A. Helvie, S. Zelakiewicz, A. Schmitz, M. Noroozian, C. Paramagul, M. A. Roubidoux, A. V. Nees, C. Neal, P. L. Carson, Y. Lu, L. M. Hadjiiski, and J. Wei, â Digital breast tomosynthesis: Observer performance study the detection clustered microcalcifications breast phantom images acquired with experimental DBT system using variable scan angles angular increments, and number of projection views,â Radiology 273, 675â 685 (2014).
dc.identifier.citedreferenceP. Blomgren, T. F. Chan, P. Mulet, L. Vese, and W.â L. Wan, Variational PDE Models and Methods for Image Processing, Numerical Analysis 1999 ( Chapman & Hall/CRC, New York, 2000 ).
dc.identifier.citedreferenceV. Bustamante, â Iterative polyenergetic digital tomosynthesis reconstructions for breast Cancer screening,â Ph.D. thesis, 2013.
dc.identifier.citedreferenceY. Lin and E. Samei, â An efficient polyenergetic SART (pSART) reconstruction algorithm for quantitative myocardial CT perfusion,â Med. Phys. 41, 021911 (14pp.) ( 2014 ). 10.1118/1.4863481
dc.identifier.citedreferenceY. Lin and E. Samei, â A fast polyâ energetic iterative FBP algorithm,â Phys. Med. Biol. 59, 1655 â 1678 ( 2014 ). 10.1088/0031â 9155/59/7/1655
dc.identifier.citedreferenceL. T. Niklason, B. T. Christian, L. E. Niklason, D. B. Kopans, D. E. Castleberry, B. H. Opsahlâ Ong, C. E. Landberg, P. J. Slanetz, A. A. Giardino, R. Moore, D. Albagli, M. C. DeJule, F. C. Fitzgerald, D. F. Fobare, B. W. Giambattista, R. F. Kwasnick, J. Liu, S. J. Lubowski, G. E. Possin, J. F. Richotte, C. Y. Wei, and R. F. Wirth, â Digital tomosynthesis in breast imaging,â Radiology 205, 399 â 406 ( 1997 ). 10.1148/radiology.205.2.9356620
dc.identifier.citedreferenceD. B. Kopans, â Novel approaches and newer imaging modalities,â in Course 815: Problemâ solving Breast Imaging, RSNA Program Book ( RSNA, Chicago, 2001 ), p. 97.
dc.identifier.citedreferenceT. Wu, A. Stewart, M. Stanton, T. McCauley, W. Phillips, D. B. Kopans, R. H. Moore, J. W. Eberhard, B. Opsahlâ Ong, L. Niklason, and M. B. Williams, â Tomographic mammography using a limited number of lowâ dose coneâ beam projection images,â Med. Phys. 30, 365 â 380 ( 2003 ). 10.1118/1.1543934
dc.identifier.citedreferenceD. B. Kopans, â Digital tomosynthesis and other applications,â in Categorical Course in Diagnostic Radiology: Breast Imagingâ Digital Mammography, RSNA Program Book ( RSNA, Chicago, 2005 ), p. 130.
dc.identifier.citedreferenceM. A. Helvie, M. A. Roubidoux, Y. Zhang, P. L. Carson, and H.â P. Chan, â Tomosynthesis mammography vs conventional mammography: Lesion detection and reader preference. Initial experience,â in RSNA Program Book ( RSNA, Chicago, 2006 ), p. 335.
dc.identifier.citedreferenceM. A. Helvie, M. A. Roubidoux, L. M. Hadjiiski, Y. Zhang, P. L. Carson, and H.â P. Chan, â Tomosynthesis mammography vs conventional mammography: Comparison of breast masses detection and characterization,â in RSNA Program Book ( RSNA, Chicago, 2007 ), p. 381.
dc.identifier.citedreferenceS. P. Poplack, T. D. Tosteson, C. A. Kogel, and H. M. Nagy, â Digital breast tomosynthesis: Initial experience in 98 women with abnormal digital screening mammography,â Am. J. Roentgenol. 189, 616 â 623 ( 2007 ). 10.2214/AJR.07.2231
dc.identifier.citedreferenceI. Andersson, D. M. Ikeda, S. Zackrisson, M. Ruschin, T. Svahn, P. Timberg, and A. Tingberg, â Breast tomosynthesis and digital mammography: A comparison of breast cancer visibility and BIRADS classification in a population of cancers with subtle mammographic findings,â Eur. Radiol. 18, 2817 â 2825 ( 2008 ). 10.1007/s00330â 008â 1076â 9
dc.identifier.citedreferenceG. Gennaro, E. Baldan, E. Bezzon, M. La Grassa, L. Pescarini, and C. di Maggio, â Clinical performance of digital breast tomosynthesis versus fullâ field digital mammography: Preliminary results,â Digital Mammography, IWDM 2008â Lecture Notes in Computer Science Vol. 5116 ( Springer, Berlin, 2008 ), pp. 477 â 482.
dc.identifier.citedreferenceM. A. Helvie, M. A. Roubidoux, L. M. Hadjiiski, Y. Zhang, P. L. Carson, and H.â P. Chan, â Research digital tomosynthesis mammography: Detection of T1 invasive breast carcinomas not diagnosed by conventional breast imaging or physical exam,â in RSNA Program Book ( RSNA, Chicago, 2008 ), p. 468.
dc.identifier.citedreferenceD. Gur, G. S. Abrams, D. M. Chough, M. A. Ganott, C. M. Hakim, R. L. Perrin, G. Y. Rathfon, J. H. Sumkin, M. L. Zuley, and A. I. Bandos, â Digital breast tomosynthesis: Observer performance study,â Am. J. Roentgenol. 193, 586 â 591 ( 2009 ). 10.2214/AJR.08.2031
dc.identifier.citedreferenceD. B. Kopans, â Digital breast tomosynthesis: Experience with imaging over 3500 subjects,â in Categorical Course in Diagnostic Radiology Physics: Advances in Digital Tomosynthesisâ From Physics to Clinical Applications, RSNA Program Book ( RSNA, Chicago, 2009 ), p. 288.
dc.identifier.citedreferenceM. A. Helvie, H.â P. Chan, L. Hadjiiski, M. M. Goodsitt, M. A. Roubidoux, and P. L. Carson, â Digital breast tomosynthesis mammography: Effect of breast density on breast mass visibility and characterization,â in RSNA Program Book 2010 LLâ BRSâ WE ( RSNA, Chicago, 2010 ).
dc.identifier.citedreferenceH.â P. Chan, Y. T. Wu, B. Sahiner, J. Wei, M. A. Helvie, Y. Zhang, R. H. Moore, D. B. Kopans, L. Hadjiiski, and T. Way, â Characterization of masses in digital breast tomosynthesis: Comparison of machine learning in projection views and reconstructed slices,â Med. Phys. 37, 3576 â 3586 ( 2010 ). 10.1118/1.3432570
dc.owningcollnameInterdisciplinary and Peer-Reviewed


Files in this item

Show simple item record

Remediation of Harmful Language

The University of Michigan Library aims to describe library materials in a way that respects the people and communities who create, use, and are represented in our collections. Report harmful or offensive language in catalog records, finding aids, or elsewhere in our collections anonymously through our metadata feedback form. More information at Remediation of Harmful Language.

Accessibility

If you are unable to use this file in its current format, please select the Contact Us link and we can modify it to make it more accessible to you.