Coronary artery analysis: Computerâ assisted selection of bestâ quality segments in multipleâ phase coronary CT angiography
dc.contributor.author | Zhou, Chuan | |
dc.contributor.author | Chan, Heang‐ping | |
dc.contributor.author | Hadjiiski, Lubomir M. | |
dc.contributor.author | Chughtai, Aamer | |
dc.contributor.author | Wei, Jun | |
dc.contributor.author | Kazerooni, Ella A. | |
dc.date.accessioned | 2017-01-06T20:51:22Z | |
dc.date.available | 2017-12-01T21:54:12Z | en |
dc.date.issued | 2016-10 | |
dc.identifier.citation | Zhou, Chuan; Chan, Heang‐ping ; Hadjiiski, Lubomir M.; Chughtai, Aamer; Wei, Jun; Kazerooni, Ella A. (2016). "Coronary artery analysis: Computerâ assisted selection of bestâ quality segments in multipleâ phase coronary CT angiography." Medical Physics 43(10): 5268-5278. | |
dc.identifier.issn | 0094-2405 | |
dc.identifier.issn | 2473-4209 | |
dc.identifier.uri | https://hdl.handle.net/2027.42/135134 | |
dc.publisher | American Association of Physicists in Medicine | |
dc.publisher | Wiley Periodicals, Inc. | |
dc.subject.other | Data sets | |
dc.subject.other | angiocardiography | |
dc.subject.other | blood vessels | |
dc.subject.other | cardiovascular system | |
dc.subject.other | computerised tomography | |
dc.subject.other | diseases | |
dc.subject.other | feature extraction | |
dc.subject.other | feature selection | |
dc.subject.other | image classification | |
dc.subject.other | image enhancement | |
dc.subject.other | image matching | |
dc.subject.other | image registration | |
dc.subject.other | image segmentation | |
dc.subject.other | medical image processing | |
dc.subject.other | optimisation | |
dc.subject.other | Computed tomography | |
dc.subject.other | Cardiac dynamics | |
dc.subject.other | Angiography | |
dc.subject.other | Registration | |
dc.subject.other | Segmentation | |
dc.subject.other | Edge enhancement | |
dc.subject.other | Computerised tomographs | |
dc.subject.other | Biological material, e.g. blood, urine; Haemocytometers | |
dc.subject.other | Digital computing or data processing equipment or methods, specially adapted for specific applications | |
dc.subject.other | Image data processing or generation, in general | |
dc.subject.other | Image enhancement or restoration, e.g. from bitâ mapped to bitâ mapped creating a similar image | |
dc.subject.other | coronary CT angiography | |
dc.subject.other | image analysis | |
dc.subject.other | computerâ aided reading | |
dc.subject.other | Vascular system | |
dc.subject.other | Radiologists | |
dc.subject.other | Medical image segmentation | |
dc.subject.other | Computed tomography | |
dc.subject.other | Medical image quality | |
dc.subject.other | Computer aided diagnosis | |
dc.subject.other | Heart | |
dc.subject.other | Heart disease | |
dc.title | Coronary artery analysis: Computerâ assisted selection of bestâ quality segments in multipleâ phase coronary CT angiography | |
dc.type | Article | en_US |
dc.rights.robots | IndexNoFollow | |
dc.subject.hlbsecondlevel | Medicine (General) | |
dc.subject.hlbtoplevel | Health Sciences | |
dc.description.peerreviewed | Peer Reviewed | |
dc.contributor.affiliationum | Department of Radiology, The University of Michigan, Ann Arbor, Michigan 48109â 0904 | |
dc.description.bitstreamurl | http://deepblue.lib.umich.edu/bitstream/2027.42/135134/1/mp1740_am.pdf | |
dc.description.bitstreamurl | http://deepblue.lib.umich.edu/bitstream/2027.42/135134/2/mp1740.pdf | |
dc.identifier.doi | 10.1118/1.4961740 | |
dc.identifier.source | Medical Physics | |
dc.identifier.citedreference | M. S. Kramer and A. R. Feinstein, â Clinical biostatistics: LIV. The biostatistics of concordance,â Clin. Pharmacol. Ther. 29, 111 â 123 ( 1981 ). 10.1038/clpt.1981.18 | |
dc.identifier.citedreference | M. H. K. Hoffmann, J. Lessick, R. Manzke, F. T. Schmid, E. Gershin, D. T. Boll, S. Rispler, A. J. Aschoff, and M. Grass, â Automatic determination of minimal cardiac motion phases for computed tomography imaging: Initial experience,â Eur. Radiol. 16, 365 â 373 ( 2006 ). 10.1007/s00330â 005â 2849â z | |
dc.identifier.citedreference | R. M. S. Joemai, J. Geleijns, W. J. H. Veldkamp, and L. J. M. Kroft, â Clinical evaluation of 64â slice CT assessment of global left ventricular function using automated cardiac phase selection,â Circ. J. 72, 641 â 646 ( 2008 ). 10.1253/circj.72.641 | |
dc.identifier.citedreference | R. M. S. Joemai, J. Geleijns, W. J. H. Veldkamp, A. de Roos, and L. J. M. Kroft, â Automated cardiac phase selection with 64â MDCT coronary angiography,â Am. J. Roentgenol. 191, 1690 â 1697 ( 2008 ). 10.2214/AJR.08.1039 | |
dc.identifier.citedreference | B. Ruzsics, M. Gebregziabher, H. Lee, R. L. Brothers, T. Allmendinger, S. Vogt, P. Costello, and U. J. Schoepf, â Coronary CT angiography: Automatic cardiacâ phase selection for image reconstruction,â Eur. Radiol. 19, 1906 â 1913 ( 2009 ). 10.1007/s00330â 009â 1368â 8 | |
dc.identifier.citedreference | C. Rohkohl, H. Bruder, K. Stierstorfer, and T. Flohr, â Improving bestâ phase image quality in cardiac CT by motion correction with MAM optimization,â Med. Phys. 40, 031901 (15pp.) ( 2013 ). 10.1118/1.4789486 | |
dc.identifier.citedreference | W. G. Austen, J. E. Edwards, R. L. Frye, G. G. Gensini, V. L. Gott, L. S. Griffith, D. C. McGoon, M. L. Murphy, and B. B. Roe, â A reporting system on patients evaluated for coronary artery disease. Report of the Ad Hoc Committee for Grading of Coronary Artery Disease, Council on Cardiovascular Surgery, American Heart Association,â Circulation 51, 5 â 40 ( 1975 ). 10.1161/01.CIR.51.4.5 | |
dc.identifier.citedreference | J. Liu, L. Hadjiiski, H.â P. Chan, C. Zhou, J. Wei, A. Chughtai, J. Kuriakose, P. Agarwal, and E. Kazerooni, â Automatic selection of best quality vessels from multipleâ phase coronary CT angiography (cCTA),â Proc. SPIE 9414, 94140E1 â 94140E9 ( 2015 ). 10.1117/12.2082637 | |
dc.identifier.citedreference | C. Zhou, H.â P. Chan, A. Chughtai, S. Patel, L. M. Hadjiiski, J. Wei, and E. A. Kazerooni, â Automated coronary artery tree extraction in coronary CT angiography using a multiscale enhancement and dynamic balloon tracking (MSCARâ DBT) method,â Comput. Med. Imaging Graphics 36, 1 â 10 ( 2012 ). 10.1016/j.compmedimag.2011.04.001 | |
dc.identifier.citedreference | C. Zhou, H.â P. Chan, A. Chughtai, J. Kuriakose, P. Agarwal, E. A. Kazerooni, L. M. Hadjiiski, S. Patel, and J. Wei, â Computerized analysis of coronary artery disease: Performance evaluation of segmentation and tracking of coronary arteries in CT angiograms (CTA),â Med. Phys. 41, 081912 (11pp.) ( 2014 ). 10.1118/1.4890294 | |
dc.identifier.citedreference | L. Hadjiiski, C. Zhou, H.â P. Chan, A. Chughtai, P. Agarwal, J. Kuriakose, E. Kazerooni, J. Wei, and S. Patel, â Coronary CT angiography (cCTA): Automated registration of coronary arterial trees from multiple phases,â Phys. Med. Biol. 59, 4661 â 4680 ( 2014 ). 10.1088/0031â 9155/59/16/4661 | |
dc.identifier.citedreference | C. Zhou, H.â P. Chan, J. W. Kuriakose, A. Chughtai, J. Wei, L. M. Hadjiiski, Y. Guo, S. Patel, and E. A. Kazerooni, â Pulmonary vessel segmentation utilizing curved planar reformation and optimal path finding (CROP) in computed tomographic pulmonary angiography (CTPA) for CAD applications,â Proc. SPIE 8315, 83150N1 â 83150N9 ( 2012 ). 10.1117/12.912446 | |
dc.identifier.citedreference | H.â P. Chan, B. Sahiner, R. F. Wagner, and N. Petrick, â Classifier design for computerâ aided diagnosis: Effects of finite sample size on the mean performance of classical and neural network classifiers,â Med. Phys. 26, 2654 â 2668 ( 1999 ). 10.1118/1.598805 | |
dc.identifier.citedreference | B. Sahiner, H.â P. Chan, N. Petrick, R. F. Wagner, and L. M. Hadjiiski, â Feature selection and classifier performance in computerâ aided diagnosis: The effect of finite sample size,â Med. Phys. 27, 1509 â 1522 ( 2000 ). 10.1118/1.599017 | |
dc.identifier.citedreference | S. Achenbach, W. Moshage, D. Ropers, and K. Bachmann, â Curved multiplanar reconstructions for the evaluation of contrastâ enhanced electronâ beam CT of the coronary arteries,â Am. J. Roentgenol. 170, 895 â 899 ( 1998 ). 10.2214/ajr.170.4.9530029 | |
dc.identifier.citedreference | C. Zhou, H.â P. Chan, B. Sahiner, L. M. Hadjiiski, A. Chughtai, S. Patel, J. Wei, J. Ge, P. N. Cascade, and E. A. Kazerooni, â Automatic multiscale enhancement and hierarchical segmentation of pulmonary vessels in CT pulmonary angiography (CTPA) images for CAD applications,â Med. Phys. 34, 4567 â 4577 ( 2007 ). 10.1118/1.2804558 | |
dc.identifier.citedreference | M. J. Budoff, S. Achenbach, R. S. Blumenthal, J. J. Carr, J. G. Goldin, P. Greenland, A. D. Guerci, J. A. C. Lima, D. J. Rader, G. D. Rubin, L. J. Shaw, and S. E. Wiegers, â Assessment of coronary artery disease by cardiac computed tomography: A scientific statement from the American Heart Association Committee on Cardiovascular Imaging and Intervention, Council on Cardiovascular Radiology and Intervention, and Committee on Cardiac Imaging, Council on Clinical Cardiology,â Circulation 114, 1761 â 1791 ( 2006 ). 10.1161/CIRCULATIONAHA.106.178458 | |
dc.identifier.citedreference | Writing group Members, D. Lloydâ Jones, R. Adams, M. Carnethon, G. De Simone, T. B. Ferguson, K. Flegal, E. Ford, K. Furie, A. Go, K. Greenlund, N. Haase, S. Hailpern, M. Ho, V. Howard, B. Kissela, S. Kittner, D. Lackland, L. Lisabeth, A. Marelli, M. McDermott, J. Meigs, D. Mozaffarian, G. Nichol, C. Oâ Donnell, V. Roger, W. Rosamond, R. Sacco, P. Sorlie, R. Stafford, J. Steinberger, T. Thom, S. Wasserthielâ Smoller, N. Wong, J. Wylieâ Rosett, and Y. Hong, â Heart disease and stroke statisticsâ 2009 update: A report from the American Heart Association Statistics Committee and Stroke Statistics Subcommittee,â Circulation 119, e21 â 181 ( 2009 ). 10.1161/CIRCULATIONAHA.108.191261 | |
dc.identifier.citedreference | J. J. Fine, C. B. Hopkins, N. Ruff, and F. C. Newton, â Comparison of accuracy of 64â slice cardiovascular computed tomography with coronary angiography in patients with suspected coronary artery disease,â Am. J. Cardiol. 97, 173 â 174 ( 2006 ). 10.1016/j.amjcard.2005.08.021 | |
dc.identifier.citedreference | M. Budoff, D. Dowe, J. Jollis, M. Gitter, J. Sutherland, E. Halamert, M. Scherer, R. Bellinger, A. Martin, R. Benton, A. Delago, and J. Min, â Diagnostic performance of 64â multidetector row coronary computed tomographic angiography for evaluation of coronary artery stenosis in individuals without known coronary artery disease: Results from the prospective multicenter accuracy (assessment by coronary computed tomographic angiography of individuals undergoing invasive coronary angiography) trial,â J. Am. Coll. Cardiol. 52, 1724 â 1732 ( 2008 ). 10.1016/j.jacc.2008.07.031 | |
dc.identifier.citedreference | J. Min, L. Shaw, R. Devereux, P. Okin, J. Weinsaft, D. Russo, N. Lippolis, D. Berman, and T. Callister, â Prognostic value of multidetector coronary computed tomographic angiography for prediction of allâ cause mortality,â J. Am. Coll. Cardiol. 50, 1161 â 1170 ( 2007 ). 10.1016/j.jacc.2007.03.067 | |
dc.identifier.citedreference | M. Garcia, J. Lessick, M. Hoffmann, and C. S. Investigators, â Accuracy of 16â row multidetector computed tomography for the assessment of coronary artery stenosis,â JAMA 296, 403 â 411 ( 2006 ). 10.1001/jama.296.4.403 | |
dc.identifier.citedreference | B. Desjardins and E. A. Kazerooni, â ECGâ gated cardiac CT,â Am. J. Roentgenol. 182, 993 â 1010 ( 2004 ). 10.2214/ajr.182.4.1820993 | |
dc.identifier.citedreference | J. Wei, C. Zhou, H.â P. Chan, A. Chughtai, S. Patel, P. Agarwal, J. Kuriakose, L. M. Hadjiiski, and E. Kazerooni, â Computerized detection of nonâ calcified plaques in coronary CT angiography: Evaluation of topological soft gradient prescreening method and luminal analysis,â Med. Phys. 41, 081901 (9pp.) ( 2014 ). 10.1118/1.4885958 | |
dc.identifier.citedreference | V. Rasche, B. Movassaghi, M. Grass, D. Schafer, and A. Buecker, â Automatic selection of the optimal cardiac phase for gated threeâ dimensional coronary xâ ray angiography,â Acad. Radiol. 13, 630 â 640 ( 2006 ). 10.1016/j.acra.2006.01.010 | |
dc.owningcollname | Interdisciplinary and Peer-Reviewed |
Files in this item
Remediation of Harmful Language
The University of Michigan Library aims to describe library materials in a way that respects the people and communities who create, use, and are represented in our collections. Report harmful or offensive language in catalog records, finding aids, or elsewhere in our collections anonymously through our metadata feedback form. More information at Remediation of Harmful Language.
Accessibility
If you are unable to use this file in its current format, please select the Contact Us link and we can modify it to make it more accessible to you.