Show simple item record

Benchmarking of the Dose Planning Method (DPM) Monte Carlo code using electron beams from a racetrack microtron

dc.contributor.authorChetty, Indrin J.
dc.contributor.authorMoran, Jean M.
dc.contributor.authorMcShan, Daniel L.
dc.contributor.authorFraass, Benedick A.
dc.contributor.authorWilderman, Scott J.
dc.contributor.authorBielajew, Alex F.
dc.date.accessioned2017-01-06T20:51:23Z
dc.date.available2017-01-06T20:51:23Z
dc.date.issued2002-06
dc.identifier.citationChetty, Indrin J.; Moran, Jean M.; McShan, Daniel L.; Fraass, Benedick A.; Wilderman, Scott J.; Bielajew, Alex F. (2002). "Benchmarking of the Dose Planning Method (DPM) Monte Carlo code using electron beams from a racetrack microtron." Medical Physics 29(6): 1035-1041.
dc.identifier.issn0094-2405
dc.identifier.issn2473-4209
dc.identifier.urihttps://hdl.handle.net/2027.42/135135
dc.publisherAmerican Association of Physicists in Medicine
dc.publisherWiley Periodicals, Inc.
dc.subject.otherPhysicists
dc.subject.otherMonte Carlo methods
dc.subject.otherion‐chamber measurements
dc.subject.otherDPM
dc.subject.otherMonte Carlo
dc.subject.otherracetrack microtron
dc.subject.otherMonte Carlo methods
dc.subject.otherIonization chambers
dc.subject.otherIon beam sources
dc.subject.otherElectron beams
dc.subject.otherelectron beam applications
dc.subject.otherelectron transport theory
dc.subject.othermedical computing
dc.subject.otherMonte Carlo methods
dc.subject.otherradiation therapy
dc.subject.otherdosimetry
dc.subject.otherTreatment strategy
dc.subject.otherDosimetry/exposure assessment
dc.titleBenchmarking of the Dose Planning Method (DPM) Monte Carlo code using electron beams from a racetrack microtron
dc.typeArticleen_US
dc.rights.robotsIndexNoFollow
dc.subject.hlbsecondlevelMedicine (General)
dc.subject.hlbtoplevelHealth Sciences
dc.description.peerreviewedPeer Reviewed
dc.contributor.affiliationumThe University of Michigan, Department of Nuclear Engineering, Ann Arbor, Michigan 48109‐2104
dc.contributor.affiliationumThe University of Michigan, Department of Radiation Oncology, Ann Arbor, Michigan 48109‐0010
dc.description.bitstreamurlhttp://deepblue.lib.umich.edu/bitstream/2027.42/135135/1/mp1512.pdf
dc.identifier.doi10.1118/1.1481512
dc.identifier.sourceMedical Physics
dc.identifier.citedreferenceR. Mohan, C. Chui, and L. Lidofsky, “ Energy and angular distributions of photons from medical linear accelerators,” Med. Phys. MPHYA6 --> 12, 592 – 597 ( 1985 ). MPHYA6 0094-2405 -->
dc.identifier.citedreferenceP. L. Petti, M. S. Goodman, T. A. Gabriel, and R. Mohan, “ Investigation of buildup dose from electron contamination of clinical photon beams,” Med. Phys. MPHYA6 --> 10, 18 – 25 ( 1983 ). MPHYA6 0094-2405 -->
dc.identifier.citedreferenceC. M. Ma, A. Kapur, T. Pawlicki, D. Findley, S. Brain, and K. Forster, “ Clinical implementation of a Monte Carlo treatment planning system,” Med. Phys. MPHYA6 --> 26, 2133 – 2143 ( 1999 ). MPHYA6 0094-2405 -->
dc.identifier.citedreferenceJ. Van Dyke, R. B. Barnett, J. E. Cygler, and P. C. Shragge, “ Commissioning and quality assurance of treatment planning computers,” Int. J. Radiat. Oncol., Biol., Phys. IOBPD3 --> 26, 261 – 273 ( 1992 ). IOBPD3 0360-3016 -->
dc.identifier.citedreferenceD. W. O. Rogers, D. A. Faddegon, G. X. Ding, C. M. Ma, J. We, and T. R. Mackie, “ BEAM: A Monte Carlo code to simulate radiotherapy treatment units,” Med. Phys. MPHYA6 --> 22, 503 – 524 ( 1995 ). MPHYA6 0094-2405 -->
dc.identifier.citedreferenceD. M. J. Lovelock, C. S. Chui, and R. Mohan, “ A Monte Carlo model of photon beams used in radiation therapy,” Med. Phys. MPHYA6 --> 22, 1387 – 1394 ( 1995 ). MPHYA6 0094-2405 -->
dc.identifier.citedreferenceJ. J. DeMarco, T. D. Solberg, R. E. Wallace, and J. B. Smathers, “ A verification of the Monte Carlo code MCNP for thick target bremsstrahlung calculations,” Med. Phys. MPHYA6 --> 22, 11 – 16 ( 1995 ). MPHYA6 0094-2405 -->
dc.identifier.citedreferenceJ. F. Briesmeister, “MCNP™‐A general Monte Carlo N‐Particle transport code,” Los Alamos National Laboratory Report No. LA‐12625‐M, 1997.
dc.identifier.citedreferenceM. Karlsson, H. Nystrom, and H. Svensson, “ Electron beam characteristics of the 50-MeV racetrack microtron,” Med. Phys. MPHYA6 --> 19, 307 – 315 ( 1992 ). MPHYA6 0094-2405 -->
dc.identifier.citedreferenceJ. Sempau, S. J. Wilderman, and A. F. Bielajew, “ DPM, a fast, accurate Monte Carlo code optimized for photon and electron radiotherapy treatment planning dose calculations,” Phys. Med. Biol. PHMBA7 --> 45, 2263 – 2291 ( 2000 ). PHMBA7 0031-9155 -->
dc.identifier.citedreferenceI. Chetty, J. J. DeMarco, and T. D. Solberg, “ A virtual source model for Monte Carlo modeling of arbitrary intensity distributions,” Med. Phys. MPHYA6 --> 27, 166 – 172 ( 2000 ). MPHYA6 0094-2405 -->
dc.identifier.citedreferenceM. K. Fix, M. Stampanoni, P. Manser, E. J. Born, R. Mini, and P. Ruegsegger, “ A multiple source model for 6 MV photon beam dose calculations,” Phys. Med. Biol. PHMBA7 --> 46, 1407 – 1428 ( 2001 ). PHMBA7 0031-9155 -->
dc.identifier.citedreferenceJ. J. DeMarco, T. D. Solberg, and J. B. Smathers, “ A CT-based Monte Carlo dosimetry tool for radiotherapy treatment planning and analysis,” Med. Phys. MPHYA6 --> 25, 1 – 11 ( 1998 ). MPHYA6 0094-2405 -->
dc.identifier.citedreferenceC. M. Ma, P. Reckwerdt, M. Holmes, D. W. O. Rogers, and B. Geiser, “DOSXYZ Users Manual,” NRCC Report No. PIRS 509B(rev C), 1998.
dc.identifier.citedreferenceJ. Deng, S. B. Jiang, J. Li, T. Pawlicki, and C. M. Ma, “ Photon beam characterization and modeling for Monte Carlo treatment planning,” Phys. Med. Biol. PHMBA7 --> 45, 411 – 427 ( 2000 ). PHMBA7 0031-9155 -->
dc.identifier.citedreferenceI. Kawrakow, M. Fippel, and K. Friedrich, “ 3D electron dose calculation using a Voxel based Monte Carlo algorithm (VMC),” Med. Phys. MPHYA6 --> 23, 445 – 457 ( 1996 ). MPHYA6 0094-2405 -->
dc.identifier.citedreferenceL. Wang, C. S. Chui, and M. Lovelock, “ A patient-specific Monte Carlo dose-calculation method for photon beams,” Med. Phys. MPHYA6 --> 25, 867 – 878 ( 1998 ). MPHYA6 0094-2405 -->
dc.identifier.citedreferenceJ. V. Siebers, P. J. Keall, J. O. Kim, and R. Mohan, “Performance benchmarks of the MCV Monte Carlo system,” in Proceedings of the XIIIth International Conference on the Use of Computers in Radiation Therapy, edited by W. Schlegel and T. Bortfeld (Springer, Berlin, 2000), pp. 129–131.
dc.identifier.citedreferenceA. E. Schach von Wittenau, L. J. Cox, P. M. Bergstrom, W. P. Chandler, and C. L. Hartmann-Siantar, “ Correlated histogram representation of Monte Carlo derived medical accelerator photon output phase space,” Med. Phys. MPHYA6 --> 26, 1196 – 1212 ( 2000 ). MPHYA6 0094-2405 -->
dc.owningcollnameInterdisciplinary and Peer-Reviewed


Files in this item

Show simple item record

Remediation of Harmful Language

The University of Michigan Library aims to describe library materials in a way that respects the people and communities who create, use, and are represented in our collections. Report harmful or offensive language in catalog records, finding aids, or elsewhere in our collections anonymously through our metadata feedback form. More information at Remediation of Harmful Language.

Accessibility

If you are unable to use this file in its current format, please select the Contact Us link and we can modify it to make it more accessible to you.