Show simple item record

Migration check tool: automatic plan verification following treatment management systems upgrade and database migration

dc.contributor.authorHadley, Scott W
dc.contributor.authorWhite, Dale
dc.contributor.authorChen, Xiaoping
dc.contributor.authorMoran, Jean M.
dc.contributor.authorKeranen, Wayne M.
dc.date.accessioned2017-01-10T19:02:53Z
dc.date.available2017-01-10T19:02:53Z
dc.date.issued2013-11
dc.identifier.citationHadley, Scott W; White, Dale; Chen, Xiaoping; Moran, Jean M.; Keranen, Wayne M. (2013). "Migration check tool: automatic plan verification following treatment management systems upgrade and database migration." Journal of Applied Clinical Medical Physics 14(6): 350-358.
dc.identifier.issn1526-9914
dc.identifier.issn1526-9914
dc.identifier.urihttps://hdl.handle.net/2027.42/135152
dc.publisherWiley Periodicals, Inc.
dc.subject.othertreatment management system
dc.subject.otherautomatic checking
dc.subject.otherpatient safety
dc.titleMigration check tool: automatic plan verification following treatment management systems upgrade and database migration
dc.typeArticleen_US
dc.rights.robotsIndexNoFollow
dc.subject.hlbsecondlevelMedicine (General)
dc.subject.hlbtoplevelHealth Sciences
dc.description.peerreviewedPeer Reviewed
dc.description.bitstreamurlhttp://deepblue.lib.umich.edu/bitstream/2027.42/135152/1/acm20350.pdf
dc.identifier.doi10.1120/jacmp.v14i6.4394
dc.identifier.sourceJournal of Applied Clinical Medical Physics
dc.identifier.citedreferenceSiochi RA, Balter P, Bloch CD, et al. A rapid communication from the AAPM Task Group 201: recommendations for the QA of external beam radiotherapy data transfer. AAPM TG 201: quality assurance of external beam radiotherapy data transfer. J Appl Clin Med Phys. 2011; 12 ( 1 ): 3479.
dc.identifier.citedreferenceFord EC, Gaudette R, Myers L, et al. Evaluation of safety in a radiation oncology setting using failure mode and effects analysis. Int J Radiat Oncol Biol Phys. 2009; 74 ( 3 ): 852 – 58.
dc.identifier.citedreferenceMoran JM, Dempsey M, Eisbruch A, et al. Safety considerations for IMRT: executive summary. Med Phys. 2011; 38 ( 9 ): 5067 – 72.
dc.identifier.citedreferenceRangaraj D, Zhu M, Yang D, et al. Catching errors with patient‐specific pretreatment machine log file analysis. Pract Radiat Oncol. 2013; 3 ( 2 ): 80 – 90.
dc.identifier.citedreferenceSiochi RA, Pennington EC, Waldron TJ, Bayouth JE. Radiation therapy plan checks in a paperless clinic. J Appl Clin Med Phys. 2009; 10 ( 1 ): 2905.
dc.identifier.citedreferenceMitra N and Lafon Y, editors. W3C SOAP Version 1.2 Part 0, second edition [Internet]. World Wide Web Consortium; 2007 [cited 2012 Dec.7]. Available from: http://www.w3.org/TR/2007/REC‐soap12‐part0–20070427/
dc.identifier.citedreferenceHuq MS, Fraass BA, Dunscombe PB, et al. A method for evaluating quality assurance needs in radiation therapy. Int J Radiat Oncol Biol Phys. 2008; 71 ( 1 Suppl ): S170 – S173.
dc.owningcollnameInterdisciplinary and Peer-Reviewed


Files in this item

Show simple item record

Remediation of Harmful Language

The University of Michigan Library aims to describe library materials in a way that respects the people and communities who create, use, and are represented in our collections. Report harmful or offensive language in catalog records, finding aids, or elsewhere in our collections anonymously through our metadata feedback form. More information at Remediation of Harmful Language.