Show simple item record

Dosimetric comparison of extended dose range film with ionization measurements in water and lung equivalent heterogeneous media exposed to megavoltage photons

dc.contributor.authorCharland, Paule M.
dc.contributor.authorChetty, Indrin J.
dc.contributor.authorYokoyama, Shigeru
dc.contributor.authorFraass, Benedick A.
dc.date.accessioned2017-01-10T19:08:15Z
dc.date.available2017-01-10T19:08:15Z
dc.date.issued2003-12
dc.identifier.citationCharland, Paule M.; Chetty, Indrin J.; Yokoyama, Shigeru; Fraass, Benedick A. (2003). "Dosimetric comparison of extended dose range film with ionization measurements in water and lung equivalent heterogeneous media exposed to megavoltage photons." Journal of Applied Clinical Medical Physics 4(1): 25-39.
dc.identifier.issn1526-9914
dc.identifier.issn1526-9914
dc.identifier.urihttps://hdl.handle.net/2027.42/135483
dc.publisherWiley Periodicals, Inc.
dc.subject.otherphoton beam dosimetry
dc.subject.otherlung
dc.subject.otherfilm dosimetry
dc.titleDosimetric comparison of extended dose range film with ionization measurements in water and lung equivalent heterogeneous media exposed to megavoltage photons
dc.typeArticleen_US
dc.rights.robotsIndexNoFollow
dc.subject.hlbsecondlevelMedicine (General)
dc.subject.hlbtoplevelHealth Sciences
dc.description.peerreviewedPeer Reviewed
dc.description.bitstreamurlhttp://deepblue.lib.umich.edu/bitstream/2027.42/135483/1/acm20025.pdf
dc.identifier.doi10.1120/jacmp.v4i1.2539
dc.identifier.sourceJournal of Applied Clinical Medical Physics
dc.identifier.citedreferenceJ. F. Williamson, F. M. Khan, and S. C. Sharma, “ Film dosimetry of megavoltage photon beams: a practical method of intensity‐to‐isodose curve conversion,” Med. Phys. 8, 94 – 98 ( 1981 ).
dc.identifier.citedreferenceL. J. van Battum and B. J. M. Heijmen, “ Film dosimetry in water in a 23 MV therapeutic photon beam,” Radiother Oncol. 34, 152 – 159 ( 1995 ).
dc.identifier.citedreferenceN. A. M. van Bree, M. H. M. Izdes, H. Huizenga, and B. J. Mijnheer, “ Film dosimetry for radiotherapy treatment planning verification of a 6 MV tangential breast irradiation,” Radiother. Oncol. 31, 251 – 255 ( 1994 ).
dc.identifier.citedreferenceP. Hoban, P. Keall, and W. Round, “ The effect of density on the 10 MV photon beam penumbra,” Australas. Phys. Eng. Sci. Med. 15, 113 – 123 ( 1992 ).
dc.identifier.citedreferenceR. C. Miller, J. A. Bonner, and R. W. Kline, “ Impact of beam energy and field margin on penumbra at tumor‐lung parenchyma interfaces,” Int. J. Radiat. Oncol., Biol., Phys. 41, 707 – 13 ( 1998 ).
dc.identifier.citedreferenceR. Mayer, A. Williams, T. Frankel, Y Chong, S. Simons, N. Yang, and R. Timmerman, “ Two‐dimensional film dosimetry application in heterogeneous materials exposed to megavoltage photon beams,” Med. Phys. 24, 455 – 460 ( 1997 ).
dc.identifier.citedreferenceE. Yorke, L. Harisiadis, B. Wessels, H. Aghdam, and R. Altemus, “ Dosimetric considerations in radiation therapy of coin lesions of the lung,” Int. J. Radiat. Oncol., Biol., Phys. 34, 481 – 487 ( 1995 ).
dc.identifier.citedreferenceM. Blomquist and M. Karlsson, “ Measured lung dose correction factors for 50 MV photons,” Phys. Med. Biol. 43, 3225 – 3234 ( 1998 ).
dc.identifier.citedreferenceC Danciu, B. S. Proimos, J. Rosenwald, and B. J. Mijnheer, “ Variation of sensitometric curves of radiographic films in high energy photon beams,” Med. Phys. 28, 966 – 974 ( 2001 ).
dc.identifier.citedreferenceN. Suchowerska, P. Hoban, M. Butson, A. Davidson, and P. Metcalfe, “ Directional dependence in film dosimetry: radiographic and radiochromic film,” Phys. Med. Biol. 46, 1391 – 1397 ( 2000 ).
dc.identifier.citedreferenceJ. R. Sykes, H. V. James, and P. C. Williams, “ How much does film sensitivity increase at depth for larger fields?,” Med. Phys. 26, 329 – 330 ( 1999 ).
dc.identifier.citedreferenceC.‐W. Cheng and I. J. Das, “ Dosimetry of high energy photon and electron beams with CEA films,” Med. Phys. 23, 1225 – 1232 ( 1996 ).
dc.identifier.citedreferenceP. Cadman, “ Use of CEA TVS film for measuring high energy photon beam distributions,” Med. Phys. 25, 1435 – 37 ( 1998 ).
dc.identifier.citedreferenceW. L. McLaughlin, Y. Chen, C. G. Soares, A. Miller, G. V. Van Dyke, and D. F. Lewis, “ Sensitometry of the response of a new radiochromic film dosimeter to gamma radiation and electron beams,” Nucl. Instrum. Methods Phys. Res. A 302, 165 – 167 ( 1995 ).
dc.identifier.citedreferenceP. J. Muench, A. S. Meigooni, R. Nath, and W. L. McLaughlin, “ Photon energy dependence of the sensitivity of radiochromic film and comparison with silver halide film and LiF TLDs used for brachytherapy dosimetry,” Med. Phys. 18, 769 – 775 ( 1991 ).
dc.identifier.citedreferenceR. Rice, J. L. Hansen, L. M. Chin, B. J. Mijnheer, and B. E. Bjärngard, “ The influence of ionization chamber and phantom design on the measurement of lung dose in photon beams,” Med. Phys. 15, 884 – 890 ( 1988 ).
dc.identifier.citedreferenceT. Mauceri and K. Kase, “ Effects of ionization chamber construction on dose measurements,” Med. Phys. 14, 653 – 656 ( 1987 ).
dc.identifier.citedreferenceAmerican Association of Physicists in Medicine, Radiation Therapy Committee Task Group 21, “ A protocol for determination of absorbed dose from high‐energy photon and electron beams,” Med. Phys. 10, 41 – 771 ( 1983 ).
dc.identifier.citedreferenceI. J. Chetty and P. Charland, “ Investigation of Kodak Extended Dose Range (EDR) film for megavoltage photon beam dosimetry,” Phys. Med. Biol. 47, 3629 ( 2002 ).
dc.identifier.citedreferenceK.‐S. Chang, F.‐F. Yin, and K.‐W. Nie, “ The effect of detector size to the broadening of the penumbra–a computer simulated study,” Med. Phys. 23, 1407 – 1411 ( 1996 ).
dc.identifier.citedreferenceB. A. Fraass, K. Doppke, M. A. Hunt, G. J. Kutcher, G. Starkschall, R. Stern, and J. Van Dyk, “ American Association of Physicists in Medicine Radiation Therapy Committee Task Group 53: Quality assurance for clinical radiotherapy treatment planning,” Med. Phys. 25, 1773 – 1829 ( 1998 ).
dc.identifier.citedreferenceJ. M. Robertson, R. K. Ten Haken, M. B. Hazuka, A. T. Turrissi, M. K. Martel, A. T. Pu, J. F. Littles, F. J. Martinez, I. R. Francis, L. E. Quint, and A. S. Lichter, “ Dose escalation for non‐small cell lung cancer using conformal radiation therapy,” Int. J. Radiat. Oncol., Biol., Phys. 37, 1079 – 85 ( 1997 ).
dc.identifier.citedreferenceR. K. Ten Haken, M. K. Martel, M. L. Kessler, M. B. Hazuka, T. S. Lawrence, J. M. Robertson, A. T. Turrissi, and A. S. Lichter, “ Use of Veff and iso_NCTP in the implementation of dose escalation protocols,” Int. J. Radiat. Oncol., Biol., Phys. 27, 689 – 95 ( 1993 ).
dc.identifier.citedreferenceT. R. Mackie, J. E. El‐Khatib, J. Battista, J. Scrimger, J. van Dyk, and J. R. Cunningham, “ Lung dose corrections for 6 and 15 MV X‐rays,” Med. Phys. 12, 327 – 332 ( 1985 ).
dc.identifier.citedreferenceM. E. J. Young and R. O. Komelson, “ Dose corrections for low‐density tissue inhomogeneities and air channels for 10‐MV x rays,” Med. Phys. 10, 450 – 5 ( 1983 ).
dc.identifier.citedreferenceA. K. Rustgi, A. Samuels, and S. N. Rustgi, “ Influence of air inhomogeneities in radiosurgical beams,” Med. Dosim. 22, 95 – 100 ( 1997 ).
dc.identifier.citedreferenceE. E. Klein, A. Morrison, J. A. Purdy, M. V. Graham, and J. Matthews, “ A volumetric study of measurements and calculations of lung density corrections for 6 MV and 18 MV photons,” Int. J. Radiat. Oncol., Biol., Phys. 37, 1163 – 1170 ( 1997 ).
dc.identifier.citedreferenceD. J. Dawson, J. M. Harper, and A. C. Akindradewo, “ Analysis of physical parameters associated with the measurement of high‐energy x‐ray penumbra,” Med. Phys. 11, 491 – 7 ( 1984 ).
dc.identifier.citedreferenceR. O. Kornelson and M. E. J. Young, “ Changes in the dose‐profile of a 10 MV x‐ray beam within and beyond low density material,” Med. Phys. 9, 114 – 16 ( 1982 ).
dc.identifier.citedreferenceE. El‐Khatib, M. Evans, M. Pla, and J. R. Cunningham, “ Evaluation of lung dose correction methods for photon irradiations of thorax phantoms,” Int. J. Radiat. Oncol., Biol., Phys. 17, 871 – 878 ( 1989 ).
dc.identifier.citedreferenceT. R. Mack, J. W. Scrimger, and J. J. Battista, “ A convolution method of calculating dose for 15 MV X‐rays,” Med. Phys. 12, 1888 – 196 ( 1985 ).
dc.identifier.citedreferenceK. E. Ekstrand and W. H. Barnes, “ Pitfalls in the use of high energy x‐rays to treat tumors in the lung,” Int. J. Radiat. Oncol., Biol., Phys. 18, 249 – 252 ( 1990 ).
dc.identifier.citedreferenceM. A. Hunt, G. E. Desobry, B. Fowble, and L. R. Coia, “ Effect of low‐density lateral interfaces on soft‐tissue doses,” Int. J. Radiat. Oncol., Biol., Phys. 37, 475 – 482 ( 1997 ).
dc.identifier.citedreferenceM. R. Arnfield, C. H. Siantar, J. Siebers, P. Carmon, L. Cox, and R. Mohan, “ The impact of electron transport on the accuracy of computed dose,” Med. Phys. 27, 1266 – 1274 ( 2000 ).
dc.identifier.citedreferenceM. J. Butson, R. Elferink, T. Cheung, P. K. N. Yu, M. Stokes, K. Y. Quach, and P. Metcalfe, “ Verification of lung dose in an anthropomorphic phantom calculated by the collapsed cone convolution method,” Phys. Med. Biol. 45, 143 – 49 ( 2000 ).
dc.identifier.citedreferenceW. U. Laub, A. Bakai, and F. Nüsslin, “ Intensity modulated irradiation of a thorax phantom: comparisons between measurements, Monte Carlo calculations and pencil beam calculations,” Phys. Med. Biol. 46, 1695 – 1706 ( 2001 ).
dc.identifier.citedreferenceM. Fippel, “ Fast Monte Carlo dose calculation for photon beams based on the VMC electron algorithm,” Med. Phys. 26, 1466 – 1475 ( 1999 ).
dc.identifier.citedreferenceJ. Sempau, S. J. Wilderman, and Alex F. Bielajew, “ DPM, a fast, accurate Monte Carlo code optimized for photon and electron radiotherapy treatment planning dose calculations,” Phys. Med. Biol. 45, 2263 – 2291 ( 2000 ).
dc.identifier.citedreferenceA. Ahnesjö, P. Andreo, and A. Brahme, “ Calculation and application of point spread functions for treatment planning with high energy photon beams,” Acta Oncol. 26, 49 – 55 ( 1987 ).
dc.identifier.citedreferenceP W. Hoban, D. C. Murray, P. E. Metcalfe, and W. H. Round, “ Superposition dose calculation in lung for 10 MV photons,” Australas. Phys. Eng. Sci. Med. 13, 81 – 92 ( 1990 ).
dc.identifier.citedreferenceM. Miften, M. Wiesmeyer, S. Monthofer, and K. Krippner, “ Implementation of FFT convolution and multigrid superposition models in the FOCUS RTP system,” Phys. Med. Biol. 45, 817 – 833 ( 2000 ).
dc.identifier.citedreferenceR. Rice, B. Mijnheer, and L. Chin, “ Benchmark measurements for lung dose corrections,” Int. J. Radiat. Oncol., Biol., Phys. 15, 399 – 409 ( 1988 ).
dc.identifier.citedreferenceJ. L. Robat and B. G. Clark, “ The use of radiographic film for linear accelerator stereotactic radiosurgical dosimetry,” Med. Phys. 26, 2144 – 2150 ( 1999 ).
dc.identifier.citedreferenceR. L. Stern, B. A. Fraass, A. Gerhardsson, D. L. McShan, and K. L. Lam, “ Generation and use of measurement‐based 3‐D dose distributions for 3‐D dose calculation verification,” Med. Phys. 19, 165 – 173 ( 1992 ).
dc.owningcollnameInterdisciplinary and Peer-Reviewed


Files in this item

Show simple item record

Remediation of Harmful Language

The University of Michigan Library aims to describe library materials in a way that respects the people and communities who create, use, and are represented in our collections. Report harmful or offensive language in catalog records, finding aids, or elsewhere in our collections anonymously through our metadata feedback form. More information at Remediation of Harmful Language.

Accessibility

If you are unable to use this file in its current format, please select the Contact Us link and we can modify it to make it more accessible to you.