Show simple item record

Analysis of couch position tolerance limits to detect mistakes in patient setup

dc.contributor.authorHadley, Scott W.
dc.contributor.authorBalter, James M.
dc.contributor.authorLam, Kwok L.
dc.date.accessioned2017-01-10T19:10:47Z
dc.date.available2017-01-10T19:10:47Z
dc.date.issued2009-09
dc.identifier.citationHadley, Scott W.; Balter, James M.; Lam, Kwok L. (2009). "Analysis of couch position tolerance limits to detect mistakes in patient setup." Journal of Applied Clinical Medical Physics 10(4): 207-219.
dc.identifier.issn1526-9914
dc.identifier.issn1526-9914
dc.identifier.urihttps://hdl.handle.net/2027.42/135643
dc.publisherWiley Periodicals, Inc.
dc.subject.otherimmobilization
dc.subject.otherrecord and verify
dc.subject.othertreatment errors
dc.subject.otherpatient safety
dc.titleAnalysis of couch position tolerance limits to detect mistakes in patient setup
dc.typeArticleen_US
dc.rights.robotsIndexNoFollow
dc.subject.hlbsecondlevelMedicine (General)
dc.subject.hlbtoplevelHealth Sciences
dc.description.peerreviewedPeer Reviewed
dc.description.bitstreamurlhttp://deepblue.lib.umich.edu/bitstream/2027.42/135643/1/acm20207.pdf
dc.identifier.doi10.1120/jacmp.v10i4.2864
dc.identifier.sourceJournal of Applied Clinical Medical Physics
dc.identifier.citedreferenceBentel G, Marks L, Hendren K, Brizel D. Comparison of two head and neck immobilization systems. Int J Radiat Oncol Biol Phys. 1997; 38 ( 4 ): 867 – 73.
dc.identifier.citedreferenceFraass B, Lash K, Matrone G, et al. The impact of treatment complexity and computer‐control delivery technology on treatment delivery errors. Int J Radiat Oncol Biol Phys. 1998; 42 ( 3 ): 651 – 59.
dc.identifier.citedreferenceBarthelemy‐Brichant N, Sabatier J, Dewé W, Albert A, Deneufbourg J. Evaluation of frequency and type of errors detected by a computerized record and verify system during radiation treatment. Radiother Oncol. 1999; 53 ( 2 ): 149 – 54.
dc.identifier.citedreferencePatton G, Gaffney D, Moeller J. Facilitation of radiotherapeutic error by computerized record and verify systems. Int J Radiat Oncol Biol Phys. 2003; 56 ( 1 ): 50 – 57.
dc.identifier.citedreferenceHuang G, Medlam G, Lee J, et al. Error in the delivery of radiation therapy: results of a quality assurance review. Int J Radiat Oncol Biol Phys. 2005; 61 ( 5 ): 1590 – 95.
dc.identifier.citedreferenceKlein E, Drzymala R, Purdy J, Michalski J. Errors in radiation oncology: a study in pathways and dosimetric impact. J Appl Clin Med Phys. 2005; 6 ( 3 ): 81 – 94.
dc.identifier.citedreferenceWilliams M. Radiotherapy near misses, incidents and errors: radiotherapy incident at Glasgow. Clin Oncol. 2007; 19 ( 1 ): 1 – 3.
dc.identifier.citedreferenceBortfeld T, van Herk M, Jiang SB. When should systematic patient positioning errors in radiotherapy be corrected? Phys Med Biol. 2002; 47 ( 23 ): N297 – 302.
dc.identifier.citedreferencede Boer HC, Heijmen BJ. A protocol for the reduction of systematic patient setup errors with minimal portal imaging workload. Int J Radiat Oncol Biol Phys. 2001; 50 ( 5 ): 1350 – 65.
dc.identifier.citedreferenceBel A, van Herk MB, Bartelink H, Lebesque JV. A verification procedure to improve patient set‐up accuracy using portal images. Radiother Oncol. 1993; 29 ( 2 ): 253 – 60.
dc.identifier.citedreferenceLitzenberg DW, Balter JMB, Lam KL, Sandler HM, Ten Haken RK. Retrospective analysis of prostate cancer patients with implanted gold markers using off‐line and adaptive therapy protocols. Int J Radiat Oncol Biol Phys. 2005; 63 ( 1 ): 123 – 33.
dc.identifier.citedreferenceThornton A, Ten Haken R, Gerhardsson A, Correll M. Three‐dimensional motion analysis of an improved head immobilization system for simulation, CT, MRI, and PET imaging. Radiother Oncol. 1991; 20 ( 4 ): 224 – 28.
dc.identifier.citedreferenceBentel G, Marks L, Sherouse G, Spencer D. A customized head and neck support system. Int J Radiat Oncol Biol Phys. 1995; 32 ( 1 ): 245 – 48.
dc.identifier.citedreferenceCarter D, Marks L, Bentel G. Impact of setup variability on incidental lung irradiation during tangential breast treatment. Int J Radiat Oncol Biol Phys. 1997; 38 ( 1 ): 109 – 15.
dc.identifier.citedreferenceFuss M, Salter B, Rassiah P, Cheek D, Cavanaugh S, Herman T. Repositioning accuracy of a commercially available double‐vacuum whole body immobilization system for stereotactic body radiation therapy. Technol Cancer Res Treat. 2004; 3 ( 1 ): 59 – 67.
dc.identifier.citedreferenceKim S, Akpati H, Kielbasa J, et al. Evaluation of intrafraction patient movement for CNS and head & neck IMRT. Med Phys. 2004; 31 ( 3 ): 500 – 06.
dc.identifier.citedreferenceEngelsman M, Rosenthal S, Michaud S, et al. Intra‐ and interfractional patient motion for a variety of immobilization devices. Med Phys. 2005; 32 ( 11 ): 3468 – 74.
dc.identifier.citedreferenceLovelock D, Hua C, Wang P, et al. Accurate setup of paraspinal patients using a noninvasive patient immobilization cradle and portal imaging. Med Phys. 2005; 32 ( 8 ): 2606 – 14.
dc.identifier.citedreferenceKlein EE, Drzymala RE, Williams R, Westfall LA, Purdy JA. A change in treatment process with a modern record and verify system. Int J Radiat Oncol Biol Phys. 1998; 42 ( 5 ): 1163 – 68.
dc.identifier.citedreferencePerry H, Mantel J, Lefkofsky M. A programmable calculator to acquire, verify and record radiation treatment parameters from a linear acceleration. Int J Radiat Oncol Biol Phys. 1976; 1 ( 9–10 ): 1023 – 26.
dc.identifier.citedreferenceDickof P, Morris P, Getz D. Vrx: a verify‐record system for radiotherapy. Med Phys. 1984; 11 ( 4 ): 525 – 27.
dc.identifier.citedreferenceMohan R, Podmaniczky K, Caley R, Lapidus A, Laughlin J. A computerized record and verify system for radiation treatments. Int J Radiat Oncol Biol Phys. 1984; 10 ( 10 ): 1975 – 85.
dc.identifier.citedreferencePodmaniczky K, Mohan R, Kutcher G, Kestler C, Vikram B. Clinical experience with a computerized record and verify system. Int J Radiat Oncol Biol Phys. 1985; 11 ( 8 ): 1529 – 37.
dc.identifier.citedreferenceGlisch C, Limberg C, Barber‐Derus S, Gillin M. Clinical application of a record and verify system in radiation oncology. Radiol Technol. 1988; 59 ( 3 ): 251 – 53.
dc.identifier.citedreferenceMiller R, van de Geijn J. The use of a bar code scanner to improve the utility and flexibility of record and verify systems used in radiation therapy. Med Phys. 1988; 15 ( 4 ): 611 – 13.
dc.identifier.citedreferenceFraass B, McShan D, Kessler M, Matrone G, Lewis J, Weaver T. A computer‐controlled conformal radiotherapy system. I: Overview. Int J Radiat Oncol Biol Phys. 1995; 33 ( 5 ): 1139 – 57.
dc.identifier.citedreferenceLeunens G, Verstraete J, Van den Bogaert W, Van Dam J, Dutreix A, van der Schueren E. Human errors in data transfer during the preparation and delivery of radiation treatment affecting the final result: “garbage in, garbage out”. Radiother Oncol. 1992; 23 ( 4 ): 217 – 22.
dc.owningcollnameInterdisciplinary and Peer-Reviewed


Files in this item

Show simple item record

Remediation of Harmful Language

The University of Michigan Library aims to describe library materials in a way that respects the people and communities who create, use, and are represented in our collections. Report harmful or offensive language in catalog records, finding aids, or elsewhere in our collections anonymously through our metadata feedback form. More information at Remediation of Harmful Language.

Accessibility

If you are unable to use this file in its current format, please select the Contact Us link and we can modify it to make it more accessible to you.